메뉴 건너뛰기




Volumn 26, Issue 5, 2007, Pages 594-599

Screening for previous refractive surgery in eye bank corneas by using optical coherence tomography

Author keywords

Donor corneas; Eye banking; Laser in situ keratomileusis; Refractive surgery

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; CORNEA; EYEBANK; FEMALE; HISTOLOGY; HUMAN; KERATOMILEUSIS; MALE; OPTICAL COHERENCE TOMOGRAPHY; ORGAN DONOR; PRIORITY JOURNAL; REFRACTIVE SURGERY; SLIT LAMP;

EID: 34547431599     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31803c5535     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 0024349852 scopus 로고
    • Accidental grafting of a donor cornea with radial keratotomy in a keratoconus patient
    • Mendez Angulo E. Accidental grafting of a donor cornea with radial keratotomy in a keratoconus patient. Refract Corneal Surg. 1989;5:198.
    • (1989) Refract Corneal Surg , vol.5 , pp. 198
    • Mendez Angulo, E.1
  • 2
    • 0036132888 scopus 로고    scopus 로고
    • Two cases of a penetrating keratoplasty with tissue from a donor who had undergone LASIK surgery
    • Michaeli-Cohen A, Lambert AC, Coloma F, et al. Two cases of a penetrating keratoplasty with tissue from a donor who had undergone LASIK surgery. Cornea. 2002;21:111-113.
    • (2002) Cornea , vol.21 , pp. 111-113
    • Michaeli-Cohen, A.1    Lambert, A.C.2    Coloma, F.3
  • 4
    • 0030817350 scopus 로고    scopus 로고
    • Screening donor corneas that have undergone PRK
    • Mannis MJ, McDonough G, Howard K, et al. Screening donor corneas that have undergone PRK. Cornea. 1997;16:683-685.
    • (1997) Cornea , vol.16 , pp. 683-685
    • Mannis, M.J.1    McDonough, G.2    Howard, K.3
  • 5
    • 0030729947 scopus 로고    scopus 로고
    • Corneal topography of human cadaver eyes donated months after radial and astigmatic keratotomy
    • Schelonka LP, Ogawa GSH. Corneal topography of human cadaver eyes donated months after radial and astigmatic keratotomy. Cornea. 1997;16:689-692.
    • (1997) Cornea , vol.16 , pp. 689-692
    • Schelonka, L.P.1    Ogawa, G.S.H.2
  • 6
    • 0032949826 scopus 로고    scopus 로고
    • Evaluation of prior photorefractive keratectomy in donor tissue
    • Terry MA, Ousley PJ, Rich LF, et al. Evaluation of prior photorefractive keratectomy in donor tissue. Cornea. 1999;18:353-358.
    • (1999) Cornea , vol.18 , pp. 353-358
    • Terry, M.A.1    Ousley, P.J.2    Rich, L.F.3
  • 7
    • 2342583350 scopus 로고    scopus 로고
    • Slitlamp, specular, and light microscope findings of human donor corneas after laser-assisted in situ keratomileusis
    • Mootha VV, Dawson D, Kumar A, et al. Slitlamp, specular, and light microscope findings of human donor corneas after laser-assisted in situ keratomileusis. Arch Ophthalmol. 2004;122:686-692.
    • (2004) Arch Ophthalmol , vol.122 , pp. 686-692
    • Mootha, V.V.1    Dawson, D.2    Kumar, A.3
  • 8
    • 0031715245 scopus 로고    scopus 로고
    • Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography
    • Lim-Bon-Siong R, Williams JM, Samapunphong S, et al. Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography. Arch Ophthalmol. 1998;116:617-623.
    • (1998) Arch Ophthalmol , vol.116 , pp. 617-623
    • Lim-Bon-Siong, R.1    Williams, J.M.2    Samapunphong, S.3
  • 9
    • 0034757685 scopus 로고    scopus 로고
    • Evaluation of donor tissue with a new videokeratoscope - the Keratron Scout
    • Stoiber J, Ruckhofer J, Hitzl W, et al. Evaluation of donor tissue with a new videokeratoscope - the Keratron Scout. Cornea. 2001;20:859-863.
    • (2001) Cornea , vol.20 , pp. 859-863
    • Stoiber, J.1    Ruckhofer, J.2    Hitzl, W.3
  • 10
    • 0342929117 scopus 로고    scopus 로고
    • Screening of donor eyes for prior PRK: Evaluation of the Orbscan and TMS-1 technologies
    • Ousley PJ, Terry MA. Screening of donor eyes for prior PRK: evaluation of the Orbscan and TMS-1 technologies. Invest Ophthalmol Vis Sci. 1997;38:S848.
    • (1997) Invest Ophthalmol Vis Sci , vol.38
    • Ousley, P.J.1    Terry, M.A.2
  • 11
    • 0033017399 scopus 로고    scopus 로고
    • New screening methods for donor eye-bank eyes
    • Terry MA, Ousley PJ. New screening methods for donor eye-bank eyes. Cornea. 1999;18:430-436.
    • (1999) Cornea , vol.18 , pp. 430-436
    • Terry, M.A.1    Ousley, P.J.2
  • 12
    • 0036187230 scopus 로고    scopus 로고
    • Objective screening methods for prior refractive surgery in donor tissue
    • Ousley PJ, Terry MA. Objective screening methods for prior refractive surgery in donor tissue. Cornea. 2002;21:181-188.
    • (2002) Cornea , vol.21 , pp. 181-188
    • Ousley, P.J.1    Terry, M.A.2
  • 13
    • 0037230687 scopus 로고    scopus 로고
    • Optical coherence tomography for the detection of laser in situ keratomileusis in donor corneas
    • Priglinger SG, Neubauer AS, May CA, et al. Optical coherence tomography for the detection of laser in situ keratomileusis in donor corneas. Cornea. 2003;22:46-50.
    • (2003) Cornea , vol.22 , pp. 46-50
    • Priglinger, S.G.1    Neubauer, A.S.2    May, C.A.3
  • 14
    • 1642346272 scopus 로고    scopus 로고
    • Detection of laser in situ keratomileusis in a postmortem eye using optical coherence tomography
    • Wolf AH, Neubauer AS, Priglinger SG, et al. Detection of laser in situ keratomileusis in a postmortem eye using optical coherence tomography. J Cataract Refract Surg. 2004;30:491-495.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 491-495
    • Wolf, A.H.1    Neubauer, A.S.2    Priglinger, S.G.3
  • 15
    • 0034899732 scopus 로고    scopus 로고
    • Real-time optical coherence tomography of the anterior segment at 1310 nm
    • Radhakrishnahan S, Rollins AM, Roth JE, et al. Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol. 2001;119:1179-1185.
    • (2001) Arch Ophthalmol , vol.119 , pp. 1179-1185
    • Radhakrishnahan, S.1    Rollins, A.M.2    Roth, J.E.3
  • 16
    • 33646122558 scopus 로고    scopus 로고
    • Corneal and anterior segment optical coherence tomography
    • Schuman JS, Puliafito CS, Fujimoto JG, eds, 2nd ed. Thorofare, NJ: SLACK;
    • Huang D, Li Y, Radhakrishnan S, et al. Corneal and anterior segment optical coherence tomography. In: Schuman JS, Puliafito CS, Fujimoto JG, eds. Optical Coherence Tomography of Ocular Diseases, 2nd ed. Thorofare, NJ: SLACK; 2004:663-676.
    • (2004) Optical Coherence Tomography of Ocular Diseases , pp. 663-676
    • Huang, D.1    Li, Y.2    Radhakrishnan, S.3
  • 17
    • 0032769681 scopus 로고    scopus 로고
    • Measurement of corneal curvature in young and older normal subjects
    • Pardhan S, Beesley J. Measurement of corneal curvature in young and older normal subjects. J Refract Surg. 1999;15:469-474.
    • (1999) J Refract Surg , vol.15 , pp. 469-474
    • Pardhan, S.1    Beesley, J.2
  • 18
    • 0035062925 scopus 로고    scopus 로고
    • The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
    • Müller LJ, Pels E, Vrensen GF. The specific architecture of the anterior stroma accounts for maintenance of corneal curvature. Br J Ophthalmol. 2001;85:437-443.
    • (2001) Br J Ophthalmol , vol.85 , pp. 437-443
    • Müller, L.J.1    Pels, E.2    Vrensen, G.F.3
  • 19
    • 0033898907 scopus 로고    scopus 로고
    • The cornea is not a piece of plastic
    • Roberts C. The cornea is not a piece of plastic. J Refract Surg. 2000;16:407-413.
    • (2000) J Refract Surg , vol.16 , pp. 407-413
    • Roberts, C.1
  • 20
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.