Volumn 17, Issue 3, 2007, Pages 197-204

Model for the response of radiographic films and implications for quality assurance;Modell für das Ansprechen radiographischer Filme und Folgerungen für die Qualitätssicherung

Author keywords

Dosimetry; film; IMRT; Monte Carlo simulation; quality assurance

Indexed keywords

ANALYTIC METHOD; ARTICLE; BREMS RADIATION; COMPARATIVE STUDY; DOSE RESPONSE; DOSIMETRY; MONTE CARLO METHOD; OPTICAL DENSITY; QUALITY CONTROL; RADIATION DOSE; RADIATION FIELD; X RAY FILM;

EID: 34547411927     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.zemedi.2007.04.005     Document Type: Article
Times cited : (2)

References (18)
  • 2
    • 84939588032 scopus 로고    scopus 로고
    • Thom E, Schmidt R. Filmdosimetrie mit einem handelsüblichen Scanner und mit MATLAB. In: Semmler W, Hrsg., Schad L, Hrsg. Medizinische Physik 2003. Deutsche Gesellschaft für Medizinische Physik, Heidelberg 2003. p. 284-5.
  • 3
    • 0030962169 scopus 로고    scopus 로고
    • A new approach to film dosimetry for high energy photon beams: latteral scatter filtering
    • Burch S.E., Kearfoot K.J., Trueblood J.H., Shells W.C., Yeo J.I., and Wang C.K.C. A new approach to film dosimetry for high energy photon beams: latteral scatter filtering. Med Phys 24 (1997) 775-783
    • (1997) Med Phys , vol.24 , pp. 775-783
    • Burch, S.E.1    Kearfoot, K.J.2    Trueblood, J.H.3    Shells, W.C.4    Yeo, J.I.5    Wang, C.K.C.6
  • 4
    • 0032808882 scopus 로고    scopus 로고
    • Perturbation of radiotherapy beams by radiographic film: measurements and Monte Carlo simulations
    • Suchowerska N., Hoban P., Davidson A., and Metcalfe P. Perturbation of radiotherapy beams by radiographic film: measurements and Monte Carlo simulations. Phys Med Biol 44 (1999) 1755-1765
    • (1999) Phys Med Biol , vol.44 , pp. 1755-1765
    • Suchowerska, N.1    Hoban, P.2    Davidson, A.3    Metcalfe, P.4
  • 5
    • 0032965356 scopus 로고    scopus 로고
    • How much does film sensitivity increase at depth for larger field sizes
    • Sykes J.R. How much does film sensitivity increase at depth for larger field sizes. Med Phys 26 (1999) 329-330
    • (1999) Med Phys , vol.26 , pp. 329-330
    • Sykes, J.R.1
  • 6
    • 0037036518 scopus 로고    scopus 로고
    • The value of radiographic film for the characterisation of intensity-modulated beams
    • Martens C., Claeys I., De Wagter C., and De Neve W. The value of radiographic film for the characterisation of intensity-modulated beams. Phys Med Biol 47 (2002) 2221-2234
    • (2002) Phys Med Biol , vol.47 , pp. 2221-2234
    • Martens, C.1    Claeys, I.2    De Wagter, C.3    De Neve, W.4
  • 8
    • 0037153141 scopus 로고    scopus 로고
    • Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy
    • Dogan N., Leybovich L.B., and Sethi A. Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy. Phys Med Biol 47 (2002) 4121-4130
    • (2002) Phys Med Biol , vol.47 , pp. 4121-4130
    • Dogan, N.1    Leybovich, L.B.2    Sethi, A.3
  • 9
    • 0037152488 scopus 로고    scopus 로고
    • Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry
    • Chetty I.J., and Charland P.M. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry. Phys Med Biol 47 (2002) 3629-3641
    • (2002) Phys Med Biol , vol.47 , pp. 3629-3641
    • Chetty, I.J.1    Charland, P.M.2
  • 10
    • 0036797460 scopus 로고    scopus 로고
    • Dosimetry of therapeutic photon beams using an extended dose range film
    • Esthappan J., Mutic S., Harms W.B., Dempsey J.F., and Low D.A. Dosimetry of therapeutic photon beams using an extended dose range film. Med Phys 29 (2002) 2438-2445
    • (2002) Med Phys , vol.29 , pp. 2438-2445
    • Esthappan, J.1    Mutic, S.2    Harms, W.B.3    Dempsey, J.F.4    Low, D.A.5
  • 11
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    • Zhu X.R., Jursinic P.A., Grimm D.F., Lopez F., Rownd J.J., and Gillin M.T. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys 29 (2002) 1687-1692
    • (2002) Med Phys , vol.29 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 12
    • 4043165773 scopus 로고    scopus 로고
    • Effect of processing time delay on the dose response of Kodak EDR film
    • Childress N.L., and Rosen I.I. Effect of processing time delay on the dose response of Kodak EDR film. Med Phys 31 (2004) 2284-2288
    • (2004) Med Phys , vol.31 , pp. 2284-2288
    • Childress, N.L.1    Rosen, I.I.2
  • 16
    • 84939588033 scopus 로고    scopus 로고
    • Altman JH. Sensitometry of black-and-white materials. In: James TH, Hrsg. The theory of the photographic process. 4th ed. New York: MacMillan Publishing Company; 1977. p. 481-516.
  • 18
    • 84939588034 scopus 로고    scopus 로고
    • Kawrakow I, Rogers DWO. The EGSnrc Code System. NRC Report PIRS-701. Ottawa: NRC; 2000.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.