Volumn 26, Issue 7, 2007, Pages 1001-1009

Exact and approximate Fourier rebinning algorithms for the solution of the data truncation problem in 3-D PET

Author keywords

Fourier rebinning; Image reconstruction; Medical imaging; Positron emission tomography (PET); Reprojection

Indexed keywords

APPROXIMATION ALGORITHMS; IMAGE RECONSTRUCTION; IMAGE RESOLUTION; INTERPOLATION; POSITRON EMISSION TOMOGRAPHY;

EID: 34547373958     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2007.897362     Document Type: Article
Times cited : (11)

References (26)
  • 1
    • 0018921312 scopus 로고
    • Fully three-dimensional positron emission tomography
    • J. G. Colsher, "Fully three-dimensional positron emission tomography," Phys. Med. Biol., vol. 25, pp. 103-105, 1980.
    • (1980) Phys. Med. Biol , vol.25 , pp. 103-105
    • Colsher, J.G.1
  • 2
    • 0023422104 scopus 로고
    • The theory of three-dimensional image reconstruction for PET
    • J. G. Rogers, R. Harrop, and P. E. Kinahan, "The theory of three-dimensional image reconstruction for PET," IEEE Trans. Med. Imag., vol. 6, pp. 239-243, 1987.
    • (1987) IEEE Trans. Med. Imag , vol.6 , pp. 239-243
    • Rogers, J.G.1    Harrop, R.2    Kinahan, P.E.3
  • 4
    • 0024610693 scopus 로고
    • Analytic three-dimensional image reconstruction using all detected events
    • P. E. Kinahan and J. G. Rogers, "Analytic three-dimensional image reconstruction using all detected events," IEEE Trans. Nucl. Sci., vol. 36, pp. 964-968, 1990.
    • (1990) IEEE Trans. Nucl. Sci , vol.36 , pp. 964-968
    • Kinahan, P.E.1    Rogers, J.G.2
  • 5
    • 0026560351 scopus 로고
    • Full data utilization in PVI using the 3-D Radon transform
    • M. W. Stazyk, J. G. Rogers, and R. Harrop, "Full data utilization in PVI using the 3-D Radon transform," Phys. Med. Biol., vol. 37, pp. 689-704, 1992.
    • (1992) Phys. Med. Biol , vol.37 , pp. 689-704
    • Stazyk, M.W.1    Rogers, J.G.2    Harrop, R.3
  • 6
    • 0028286963 scopus 로고
    • Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner
    • P. E. Kinahan and J. S. Karp, "Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner," Phys. Med. Biol., vol. 39, pp. 631-642, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 631-642
    • Kinahan, P.E.1    Karp, J.S.2
  • 7
    • 0035428579 scopus 로고    scopus 로고
    • 3-D-FRP: Direct Fourier reconstruction with Fourier reprojection for fully 3-D PET
    • Aug
    • S. Matej and R. M. Lewitt, "3-D-FRP: Direct Fourier reconstruction with Fourier reprojection for fully 3-D PET," IEEE Trans. Nucl. Sci., vol. 48, no. 4, pp. 1378-1385, Aug. 2001.
    • (2001) IEEE Trans. Nucl. Sci , vol.48 , Issue.4 , pp. 1378-1385
    • Matej, S.1    Lewitt, R.M.2
  • 8
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in three-dimensional PET," J. Nucl. Med., vol. 28, pp. 1717-1724, 1987.
    • (1987) J. Nucl. Med , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 9
    • 0028351749 scopus 로고
    • Three-dimensional reconstruction for PET by multi-slice rebinning and axial image filtering
    • R. M. Lewitt, G. Muehllehner, and J. S. Karp, "Three-dimensional reconstruction for PET by multi-slice rebinning and axial image filtering," Phys. Med. Biol., vol. 39, pp. 321-340, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 321-340
    • Lewitt, R.M.1    Muehllehner, G.2    Karp, J.S.3
  • 10
    • 0028355283 scopus 로고
    • 3-D reconstruction for a multi-ring PET scanner by single-slice rebinning and axial deconvolution
    • K. Erlandsson, P. D. Esser, S.-E. Strand, and R. L. Van Heertum, "3-D reconstruction for a multi-ring PET scanner by single-slice rebinning and axial deconvolution," Phys. Med. Biol., vol. 39, pp. 619-629, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 619-629
    • Erlandsson, K.1    Esser, P.D.2    Strand, S.-E.3    Van Heertum, R.L.4
  • 11
    • 0003376263 scopus 로고
    • A factorization method for the 3-D X-ray transform
    • M. Defrise, "A factorization method for the 3-D X-ray transform," Inverse Problems, vol. 11, pp. 983-994, 1995.
    • (1995) Inverse Problems , vol.11 , pp. 983-994
    • Defrise, M.1
  • 13
    • 0031972150 scopus 로고    scopus 로고
    • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3-D PET
    • E. Tanaka and Y. Amo, "A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3-D PET," Phys. Med. Biol., vol. 43, pp. 739-746, 1998.
    • (1998) Phys. Med. Biol , vol.43 , pp. 739-746
    • Tanaka, E.1    Amo, Y.2
  • 15
    • 0001380259 scopus 로고    scopus 로고
    • M. Defrise, X., and Liu, A fast rebinning algorithm for 3-D PET using John's equation, Inverse Problems, 15, pp. 1047-1065, 1999.
    • M. Defrise, X., and Liu, "A fast rebinning algorithm for 3-D PET using John's equation," Inverse Problems, vol. 15, pp. 1047-1065, 1999.
  • 16
    • 0028330542 scopus 로고
    • The perfor-mance of the single-slice rebinning for imaging the human striatum as evaluated by phantom studies
    • V. Sossi, M. W. Stazyk, P. E. Kinahan, and T. J. Ruth, "The perfor-mance of the single-slice rebinning for imaging the human striatum as evaluated by phantom studies," Phys. Med. Biol., vol. 39, pp. 369-380, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 369-380
    • Sossi, V.1    Stazyk, M.W.2    Kinahan, P.E.3    Ruth, T.J.4
  • 17
    • 0041839306 scopus 로고
    • Image reconstruction algorithms for volume imaging PET scanners,
    • Ph.D. dissertation, Univ. Pennsylvania, Philadelphia, PA
    • P. E. Kinahan, "Image reconstruction algorithms for volume imaging PET scanners," Ph.D. dissertation, Univ. Pennsylvania, Philadelphia, PA, 1994.
    • (1994)
    • Kinahan, P.E.1
  • 18
    • 34547353181 scopus 로고
    • A performance study of 3-D reconstruction algorithms for PET
    • M. Defrise, A. Geissbuhler, and D. W. Townsend, "A performance study of 3-D reconstruction algorithms for PET," Phys. Med. Biol., vol. 39, pp. 321-340, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 321-340
    • Defrise, M.1    Geissbuhler, A.2    Townsend, D.W.3
  • 19
    • 0031971783 scopus 로고    scopus 로고
    • Performance of the Fourier rebinning algorithm for the 3-D PET with large acceptance angles
    • S. Matej, J. S. Karp, R. M. Lewitt, and A. J. Becher, "Performance of the Fourier rebinning algorithm for the 3-D PET with large acceptance angles," Phys. Med. Biol., vol. 43, pp. 787-797, 1998.
    • (1998) Phys. Med. Biol , vol.43 , pp. 787-797
    • Matej, S.1    Karp, J.S.2    Lewitt, R.M.3    Becher, A.J.4
  • 21
    • 0031195397 scopus 로고    scopus 로고
    • Multishot rosette trajectories for spectrally selective MR imaging
    • Aug
    • D. C. Noll, "Multishot rosette trajectories for spectrally selective MR imaging," IEEE Trans. Med. Imag., vol. 16, no. 4, pp. 372-377, Aug. 1997.
    • (1997) IEEE Trans. Med. Imag , vol.16 , Issue.4 , pp. 372-377
    • Noll, D.C.1
  • 22
    • 0032957342 scopus 로고    scopus 로고
    • Sampling density compensation in MRI: Rationale and an iterative numerical solutions
    • J. G. Pipe and P. Menon, "Sampling density compensation in MRI: Rationale and an iterative numerical solutions," Magn. Reson. Med., vol. 41, no. 1, pp. 179-186, 1999.
    • (1999) Magn. Reson. Med , vol.41 , Issue.1 , pp. 179-186
    • Pipe, J.G.1    Menon, P.2
  • 23
    • 0037306521 scopus 로고    scopus 로고
    • Non uniform fast Fourier transforms using min-max interpolation
    • Feb
    • J. A. Fessier and B. P. Sutton, "Non uniform fast Fourier transforms using min-max interpolation," IEEE Trans. Signal Process., vol. 51, no. 2, pp. 560-574, Feb. 2003.
    • (2003) IEEE Trans. Signal Process , vol.51 , Issue.2 , pp. 560-574
    • Fessier, J.A.1    Sutton, B.P.2
  • 24
    • 33746191846 scopus 로고    scopus 로고
    • Fourier-based reconstruction for Fully 3-D PET: Optimization of interpolation parameters
    • Jul
    • S. Matej and I. G. Kazantsev, "Fourier-based reconstruction for Fully 3-D PET: Optimization of interpolation parameters," IEEE Trans. Med. Imag., vol. 25, no. 7, pp. 845-854, Jul. 2006.
    • (2006) IEEE Trans. Med. Imag , vol.25 , Issue.7 , pp. 845-854
    • Matej, S.1    Kazantsev, I.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.