메뉴 건너뛰기




Volumn , Issue , 2006, Pages 2197-2200

Switched-capacitor based implantable low-power wireless microstimulating systems

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; ELECTRIC CHARGE; PARAMETER ESTIMATION; SWITCHING; WAVEFORM ANALYSIS; WIRELESS TELECOMMUNICATION SYSTEMS;

EID: 34547363798     PISSN: 02714310     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (42)

References (22)
  • 1
    • 1942424759 scopus 로고    scopus 로고
    • Neural engineering's image problem
    • Apr
    • J. Cavuoto, "Neural engineering's image problem," IEEE Spectrum, vol. 41, pp. 32-37, Apr. 2004.
    • (2004) IEEE Spectrum , vol.41 , pp. 32-37
    • Cavuoto, J.1
  • 3
    • 34547363964 scopus 로고    scopus 로고
    • A wireless microsystem for neural stimulating microprobes,
    • Ph.D. dissertation, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Jul
    • M. Ghovanloo, "A wireless microsystem for neural stimulating microprobes," Ph.D. dissertation, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Jul. 2004.
    • (2004)
    • Ghovanloo, M.1
  • 4
    • 10444234239 scopus 로고    scopus 로고
    • A modular 32-site wireless neural stimulation microsystem
    • Dec
    • M. Ghovanloo and K. Najafi, "A modular 32-site wireless neural stimulation microsystem," IEEE J. Solid-State Circuits, vol. 39, no. 12, pp. 2457-2466, Dec. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.12 , pp. 2457-2466
    • Ghovanloo, M.1    Najafi, K.2
  • 5
    • 0029292398 scopus 로고
    • Low power microelectronics: Retrospect and prospect
    • Apr
    • J.D. Meindl, "Low power microelectronics: retrospect and prospect," Proc. of the IEEE, vol. 83, pp. 619-635, Apr. 1995.
    • (1995) Proc. of the IEEE , vol.83 , pp. 619-635
    • Meindl, J.D.1
  • 6
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • Feb
    • D.R. Merrill, M. Bikson, and J.G.R. Jefferys, "Electrical stimulation of excitable tissue: design of efficacious and safe protocols," J. Neuroscience Methods, vol. 141, pp. 171-198, Feb. 2005.
    • (2005) J. Neuroscience Methods , vol.141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 7
    • 10444220925 scopus 로고    scopus 로고
    • A very low-power CMOS mixed-signal IC for implantable pacemaker applications
    • Dec
    • L.S.Y. Wong, S. Hossain, A Ta, J. Edvinsson, D.H. Rivas, H. Naas, "A very low-power CMOS mixed-signal IC for implantable pacemaker applications," IEEE J. Solid-State Circuits, vol. 39, no. 12, pp. 2446-2456, Dec. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.12 , pp. 2446-2456
    • Wong, L.S.Y.1    Hossain, S.2    Ta, A.3    Edvinsson, J.4    Rivas, D.H.5    Naas, H.6
  • 8
    • 2442713791 scopus 로고    scopus 로고
    • A power-efficient voltage-based neural tissue stimulator with energy recovery
    • Feb
    • S.K. Kelly, J. Wyatt, "A power-efficient voltage-based neural tissue stimulator with energy recovery," IEEE Digest Intl. Solid-State Cir. Conf, pp. 228-524, Feb. 2004
    • (2004) IEEE Digest Intl. Solid-State Cir. Conf , pp. 228-524
    • Kelly, S.K.1    Wyatt, J.2
  • 9
    • 11144310593 scopus 로고    scopus 로고
    • Area saving stimulator cells for multielectrode arrays featuring adaptive waveform generation and monitoring
    • M. Schwarz, M. Maschmann, "Area saving stimulator cells for multielectrode arrays featuring adaptive waveform generation and monitoring," Proc. IEEE Eng. in Med. Biol. Conf, vol. 2, pp. 4314-4317, 2004.
    • (2004) Proc. IEEE Eng. in Med. Biol. Conf , vol.2 , pp. 4314-4317
    • Schwarz, M.1    Maschmann, M.2
  • 10
    • 34547298263 scopus 로고    scopus 로고
    • W.M. Grill presentation, Neural Interfaces Workshop, National Institute of Neural Disorders and Stroke, NIH, DC, Nov. 2004.
    • W.M. Grill presentation, Neural Interfaces Workshop, National Institute of Neural Disorders and Stroke, NIH, DC, Nov. 2004.
  • 11
    • 34547314609 scopus 로고    scopus 로고
    • Soletra 7460, MemoryMod software cartridge for deep brain stimulation
    • Medtronic Inc
    • Medtronic Inc., "Soletra 7460, MemoryMod software cartridge for deep brain stimulation," application manual, 2003
    • (2003) application manual
  • 12
    • 13444252507 scopus 로고    scopus 로고
    • Choosing electrodes for deep brain stimulation experiments - electrochemical considerations
    • Mar
    • J. Gimsa, B. Habel, U. Schreiber et al., "Choosing electrodes for deep brain stimulation experiments - electrochemical considerations," J. Neuroscience Methods, vol. 142, pp. 251-265, Mar. 2005.
    • (2005) J. Neuroscience Methods , vol.142 , pp. 251-265
    • Gimsa, J.1    Habel, B.2    Schreiber, U.3
  • 13
    • 4644311420 scopus 로고    scopus 로고
    • Selection of stimulus parameters for deep brain stimulation
    • Jul
    • A.M. Kuncel, W.M. Grill, "Selection of stimulus parameters for deep brain stimulation," Clinical Neurophysiology, vol. 115, pp. 2431-2441, Jul. 2004.
    • (2004) Clinical Neurophysiology , vol.115 , pp. 2431-2441
    • Kuncel, A.M.1    Grill, W.M.2
  • 14
    • 0030088055 scopus 로고    scopus 로고
    • The effect of stimulus pulse width duration on selectivity of neural stimulation
    • Feb
    • W.M. Grill and J.T. Mortimer, "The effect of stimulus pulse width duration on selectivity of neural stimulation," IEEE Trans. Biomed. Eng., vol. 43, no. 2, pp. 161-166, Feb. 1996.
    • (1996) IEEE Trans. Biomed. Eng , vol.43 , Issue.2 , pp. 161-166
    • Grill, W.M.1    Mortimer, J.T.2
  • 15
    • 34547254827 scopus 로고    scopus 로고
    • Tantalum capacitor
    • Editorial electronics report, Feb, Available
    • Editorial electronics report, "Tantalum capacitor", Appliance Magazine, Feb. 2005, Available: http://www.appliancemagazine. com
    • (2005) Appliance Magazine
  • 16
    • 34547285142 scopus 로고    scopus 로고
    • AVX tantalum and niobium oxide capacitors, version 2.1, AVX corporation, Oct. 2005, Available
    • AVX tantalum and niobium oxide capacitors, version 2.1, AVX corporation, Oct. 2005, Available: http:/www.avx.com
  • 17
    • 0022768090 scopus 로고
    • Integrated semiconductor magnetic field sensors
    • Aug
    • H.P. Baltes, R.S. Popovic, "Integrated semiconductor magnetic field sensors," Proc. IEEE, vol. 74, pp. 1107-1132, Aug. 1986.
    • (1986) Proc. IEEE , vol.74 , pp. 1107-1132
    • Baltes, H.P.1    Popovic, R.S.2
  • 19
    • 11244299267 scopus 로고    scopus 로고
    • A compact large voltage compliance high output impedance programmable current source for biomedical implantable microstimulators
    • Jan
    • M. Ghovanloo and K. Najafi, "A compact large voltage compliance high output impedance programmable current source for biomedical implantable microstimulators," IEEE Trans. Biomed. Eng., vol. 52, pp. 97-105, Jan. 2005.
    • (2005) IEEE Trans. Biomed. Eng , vol.52 , pp. 97-105
    • Ghovanloo, M.1    Najafi, K.2
  • 20
    • 0002027562 scopus 로고
    • Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation
    • W.F. Agnew and D.B. McCreery, Eds. Englewood Cliffs, NJ: Prentice-Hall, ch. 2, pp
    • L.S. Robblee and T.L. Rose, "Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation," in Neural Prostheses: Fundamental Studies, W.F. Agnew and D.B. McCreery, Eds. Englewood Cliffs, NJ: Prentice-Hall, 1990, ch. 2, pp. 26-66.
    • (1990) Neural Prostheses: Fundamental Studies , pp. 26-66
    • Robblee, L.S.1    Rose, T.L.2
  • 21
    • 0033932838 scopus 로고    scopus 로고
    • Chronic neural stimulation with thin-film, iridium oxide electrodes
    • July
    • J.D. Weiland and D.J. Anderson, "Chronic neural stimulation with thin-film, iridium oxide electrodes," IEEE Trans. Biomed. Eng., vol. 47, no. 7, pp. 911-918, July 2000.
    • (2000) IEEE Trans. Biomed. Eng , vol.47 , Issue.7 , pp. 911-918
    • Weiland, J.D.1    Anderson, D.J.2
  • 22
    • 84867365178 scopus 로고    scopus 로고
    • Development of a switched-capacitor based neurostimulating system for low-power head-mounted deep brain stimulators
    • Presented at the, Sep
    • M. Ghovanloo, O. Favorov, R.W. Murrow, and M. Tommerdahl, "Development of a switched-capacitor based neurostimulating system for low-power head-mounted deep brain stimulators," Presented at the NIH-NINDS Neural Interfaces Workshop in DC, Sep. 2005.
    • (2005) NIH-NINDS Neural Interfaces Workshop in DC
    • Ghovanloo, M.1    Favorov, O.2    Murrow, R.W.3    Tommerdahl, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.