메뉴 건너뛰기




Volumn 30, Issue 2, 2007, Pages 111-119

An investigation of central axis depth dose distribution pertubation due to an air gap between patients and bolus for electron beams

Author keywords

Air gap; Bolus; Electron beam

Indexed keywords

ELECTRON BEAMS; RADIOLOGY; RADIOTHERAPY; SKIN; TISSUE; TISSUE ENGINEERING;

EID: 34547117893     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178415     Document Type: Article
Times cited : (37)

References (12)
  • 5
    • 0014097598 scopus 로고
    • High-energy electron dose perturbations in regions of tissue heterogeneity. II. Physical models of tissue heterogeneities
    • Boone, M. L., Almond, P. R. and Wright, A. E., High-energy electron dose perturbations in regions of tissue heterogeneity. II. Physical models of tissue heterogeneities. Radiology 88(6): 1146-53, 1967
    • (1967) Radiology , vol.88 , Issue.6 , pp. 1146-1153
    • Boone, M.L.1    Almond, P.R.2    Wright, A.E.3
  • 6
    • 0026598999 scopus 로고
    • Study of elasto-gel pads used as surface bolus material in high energy photon and electron therapy
    • Chang, F., Chang, P., Benson, K. and Share, F., Study of elasto-gel pads used as surface bolus material in high energy photon and electron therapy. Int J Radiat Oncol Biol Phys 22(1): 191-3, 1992.
    • (1992) Int J Radiat Oncol Biol Phys , vol.22 , Issue.1 , pp. 191-193
    • Chang, F.1    Chang, P.2    Benson, K.3    Share, F.4
  • 7
    • 0029791176 scopus 로고    scopus 로고
    • Moldable tissue equivalent bolusfor high-energy photon and electron therapy
    • Dubois, D., Bice, W., Bradford, B., Schneid, T. and Engelmeier, R., Moldable tissue equivalent bolusfor high-energy photon and electron therapy. Med Phys 23(9): 1547-9, 1996.
    • (1996) Med Phys , vol.23 , Issue.9 , pp. 1547-1549
    • Dubois, D.1    Bice, W.2    Bradford, B.3    Schneid, T.4    Engelmeier, R.5
  • 8
    • 0030341833 scopus 로고    scopus 로고
    • Design and production of wax compensators for electron treatments of the chest wall
    • Tobler, M. and Leavitt, D.D., Design and production of wax compensators for electron treatments of the chest wall. Medical Dosimetry. 21(4), pp. 199-206, 1996.
    • (1996) Medical Dosimetry , vol.21 , Issue.4 , pp. 199-206
    • Tobler, M.1    Leavitt, D.D.2
  • 11
    • 0027172790 scopus 로고
    • Surface dose perturbation due to air gap between patient and bolus for electron beams
    • Sharma, S.C. and Johnson, M.W., Surface dose perturbation due to air gap between patient and bolus for electron beams. Med Phys. 20: 377-378, 1993.
    • (1993) Med Phys , vol.20 , pp. 377-378
    • Sharma, S.C.1    Johnson, M.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.