메뉴 건너뛰기




Volumn 52, Issue 15, 2007, Pages 4525-4540

The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; DETECTORS; KINETIC PARAMETERS; PARAMETER ESTIMATION; TOMOGRAPHY;

EID: 34547106035     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/15/011     Document Type: Article
Times cited : (2)

References (31)
  • 2
    • 0003191028 scopus 로고    scopus 로고
    • Bedside tomographic scintigraphy: A diagnostic tool in intensive care and the emergency room
    • Bone D, Persson M, Ribbe T and Dale S 2001 Bedside tomographic scintigraphy: a diagnostic tool in intensive care and the emergency room Nucl. Instrum. Methods Phys. Res. A 471 156-9
    • (2001) Nucl. Instrum. Methods Phys. Res. , vol.471 , Issue.1-2 , pp. 156-159
    • Bone, D.1    Persson, M.2    Ribbe, T.3    Dale, S.4
  • 7
    • 34547113610 scopus 로고    scopus 로고
    • First simulation results of a stationary SPECT camera with fast temporal resolution
    • Clackdoyle R and Roberts J A 2004 First simulation results of a stationary SPECT camera with fast temporal resolution J. Nucl. Med. 45 100
    • (2004) J. Nucl. Med. , vol.45 , pp. 100
    • Clackdoyle, R.1    Roberts, J.A.2
  • 8
    • 0025131189 scopus 로고
    • Tomography using a rotating slant-hole collimator and a large number of projections
    • Dale S and Bone D 1990 Tomography using a rotating slant-hole collimator and a large number of projections J. Nucl. Med. 31 1675-81
    • (1990) J. Nucl. Med. , vol.31 , Issue.10 , pp. 1675-1681
    • Dale, S.1    Bone, D.2
  • 10
    • 33744550629 scopus 로고    scopus 로고
    • Truncated Hilbert transform and image reconstruction from limited tomographic data
    • Defrise M, Noo F, Clackdoyle R and Kudo H 2006 Truncated Hilbert transform and image reconstruction from limited tomographic data Inverse Problems 22 1037-53
    • (2006) Inverse Problems , vol.22 , Issue.3 , pp. 1037-1053
    • Defrise, M.1    Noo, F.2    Clackdoyle, R.3    Kudo, H.4
  • 14
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H M and Larkin R S 1994 Accelerated image reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , Issue.4 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 15
    • 0034178297 scopus 로고    scopus 로고
    • List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling
    • Huesman R H, Klein G J, Moses W W, Qi J, Reutter B W and Virador P R G 2000a List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling IEEE Trans. Med. Imaging 19 532-7
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.5 , pp. 532-537
    • Huesman, R.H.1    Klein, G.J.2    Moses, W.W.3    Qi, J.4    Reutter, B.W.5    Virador, P.R.G.6
  • 17
    • 7244251647 scopus 로고    scopus 로고
    • LOR-OSEM: Statistical PET reconstruction from raw line-of-response histograms
    • Kadrmas D J 2004 LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms Phys. Med. Biol. 49 4731-44
    • (2004) Phys. Med. Biol. , vol.49 , Issue.20 , pp. 4731-4744
    • Kadrmas, D.J.1
  • 18
    • 0021354733 scopus 로고
    • Simulated ECT of the left ventricle using rotating slant-hole collimator and two camera positions
    • Koral K F, Nolder C, Ciliax G, Rogers W L and Keyes J W 1984 Simulated ECT of the left ventricle using rotating slant-hole collimator and two camera positions J. Nucl. Med. 25 343-51
    • (1984) J. Nucl. Med. , vol.25 , Issue.3 , pp. 343-351
    • Koral, K.F.1    Nolder, C.2    Ciliax, G.3    Rogers, W.L.4    Keyes, J.W.5
  • 19
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lang K and Carson R 1984 EM reconstruction algorithms for emission and transmission tomography J. Comput. Assist. Tomogr. 8 306-16
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , Issue.2 , pp. 306-316
    • Lang, K.1    Carson, R.2
  • 20
    • 0000337825 scopus 로고
    • Theory of three dimensional reconstruction: I. Conditions for a complete set of projections
    • Orlov S S 1975 Theory of three dimensional reconstruction: I. Conditions for a complete set of projections Sov. Phys.-Crystallogr. 20 312-4
    • (1975) Sov. Phys.-Crystallogr. , vol.20 , pp. 312-314
    • Orlov, S.S.1
  • 21
    • 0032034223 scopus 로고    scopus 로고
    • List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
    • Parra L and Barrett H H 1998 List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET IEEE Trans. Med. Imaging 17 228-35
    • (1998) IEEE Trans. Med. Imaging , vol.17 , Issue.2 , pp. 228-235
    • Parra, L.1    Barrett, H.H.2
  • 22
    • 0030773587 scopus 로고    scopus 로고
    • An investigation into the effect of input function shape and image acquisition interval on estimates of washin for dynamic cardiac SPECT
    • Ross S G, Welch A, Gullberg G T and Huesman R H 1997 An investigation into the effect of input function shape and image acquisition interval on estimates of washin for dynamic cardiac SPECT Phys. Med. Biol. 42 2193-213
    • (1997) Phys. Med. Biol. , vol.42 , Issue.11 , pp. 2193-2213
    • Ross, S.G.1    Welch, A.2    Gullberg, G.T.3    Huesman, R.H.4
  • 23
    • 33746851681 scopus 로고    scopus 로고
    • Segars W P 2001 Development and applications of the new dynamic NURBS-based cardiac-torso (NCAT) phantom PhD Thesis University of North Carolina, USA
    • (2001) PhD Thesis
    • Segars, W.P.1
  • 24
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L A and Vardi Y 1982 Maximum likelihood reconstruction for emission tomography IEEE Trans. Med. Imaging 1 113-22
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 25
    • 0035212751 scopus 로고    scopus 로고
    • Reconstruction of dynamic renal tomographic data acquired by slow rotation
    • Sitek A, Gullberg G T, DiBella E V and Celler A 2001 Reconstruction of dynamic renal tomographic data acquired by slow rotation J. Nucl. Med. 42 1704-12
    • (2001) J. Nucl. Med. , vol.42 , Issue.11 , pp. 1704-1712
    • Sitek, A.1    Gullberg, G.T.2    Dibella, E.V.3    Celler, A.4
  • 26
    • 0028264788 scopus 로고
    • Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model
    • Smith A M, Gullberg G T, Christian P E and Datz F L 1994 Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model J. Nucl. Med. 35 484-95
    • (1994) J. Nucl. Med. , vol.35 , pp. 484-495
    • Smith, A.M.1    Gullberg, G.T.2    Christian, P.E.3    Datz, F.L.4
  • 27
    • 0037036605 scopus 로고    scopus 로고
    • Exact inversion of the exponential X-Ray transform for RSH SPECT
    • Wagner J M, Noo F and Clackdoyle R 2002 Exact inversion of the exponential X-Ray transform for RSH SPECT Phys. Med. Biol. 47 2713-26
    • (2002) Phys. Med. Biol. , vol.47 , Issue.15 , pp. 2713-2726
    • Wagner, J.M.1    Noo, F.2    Clackdoyle, R.3
  • 28
    • 0037292177 scopus 로고    scopus 로고
    • Attenuation correction for rotating slant-hole (RSH) SPECT using exact rebinning
    • Wagner J M, Noo F, Clackdoyle R, Bal G and Christian P E 2003 Attenuation correction for rotating slant-hole (RSH) SPECT using exact rebinning IEEE Trans. Nucl. Sci. 50 110-6
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.1 , pp. 110-116
    • Wagner, J.M.1    Noo, F.2    Clackdoyle, R.3    Bal, G.4    Christian, P.E.5
  • 29
    • 0028803373 scopus 로고
    • An investigation of the effect of finite system resolution and photon noise on the bias and precision of dynamic cardiac SPECT parameters
    • Welch A, Smith A M and Gullberg G T 1995 An investigation of the effect of finite system resolution and photon noise on the bias and precision of dynamic cardiac SPECT parameters Med. Phys. 22 1829-36
    • (1995) Med. Phys. , vol.22 , Issue.11 , pp. 1829-1836
    • Welch, A.1    Smith, A.M.2    Gullberg, G.T.3
  • 30
    • 34547101551 scopus 로고    scopus 로고
    • Wessel D E 1999 Rotating slant hole single-photon emission computed tomography PhD Thesis Department of Biomedical Engineering, University of North Carolina at Chapel Hill, USA
    • (1999) PhD Thesis
    • Wessel, D.E.1
  • 31
    • 1642569142 scopus 로고    scopus 로고
    • Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    • Zou Y and Pan X 2004 Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT Phys. Med. Biol. 49 941-59
    • (2004) Phys. Med. Biol. , vol.49 , Issue.6 , pp. 941-959
    • Zou, Y.1    Pan, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.