메뉴 건너뛰기




Volumn 5, Issue 8, 2007, Pages 1686-1692

Japanese collaborative study to assess inter-laboratory variation in factor VII activity assays

Author keywords

Calibration plasma; Factor VII activity; Interlaboratory variability; Standard activity curve; Thromboplastin

Indexed keywords

BLOOD CLOTTING FACTOR 7; RECOMBINANT THROMBOPLASTIN; THROMBOPLASTIN;

EID: 34447635881     PISSN: 15387933     EISSN: 15387836     Source Type: Journal    
DOI: 10.1111/j.1538-7836.2007.02612.x     Document Type: Article
Times cited : (9)

References (30)
  • 2
    • 0036040213 scopus 로고    scopus 로고
    • Factor VII deficiency
    • Perry DJ. Factor VII deficiency. Br J Haematol 2002; 118: 689-700.
    • (2002) Br J Haematol , vol.118 , pp. 689-700
    • Perry, D.J.1
  • 4
    • 0034883006 scopus 로고    scopus 로고
    • Severe FVII deficiency with recurrent intracranial hemorrhages owing to double heterozygosity for a splice site mutation of an IVS4 and a novel nonsense mutation in exon 8 (Gln211→Term)
    • Takamiya O, Okimoto Y. Severe FVII deficiency with recurrent intracranial hemorrhages owing to double heterozygosity for a splice site mutation of an IVS4 and a novel nonsense mutation in exon 8 (Gln211→Term). Br J Haematol 2001; 114: 369-74.
    • (2001) Br J Haematol , vol.114 , pp. 369-374
    • Takamiya, O.1    Okimoto, Y.2
  • 9
    • 0015623742 scopus 로고
    • Sensitivity of commercial thromboplastins to factor VII
    • Singer JW, Sibley CA. Sensitivity of commercial thromboplastins to factor VII. Am J Clin Pathol 1973; 59: 755-9.
    • (1973) Am J Clin Pathol , vol.59 , pp. 755-759
    • Singer, J.W.1    Sibley, C.A.2
  • 10
    • 0026092804 scopus 로고
    • Factor VII clotting assay: Influence of different thromboplastins and factor VII-deficient plasmas
    • Poggio M, Tripodi A, Mariani G, Mannucci PM. Factor VII clotting assay: influence of different thromboplastins and factor VII-deficient plasmas. Thromb Haemost 1991; 65: 160-4.
    • (1991) Thromb Haemost , vol.65 , pp. 160-164
    • Poggio, M.1    Tripodi, A.2    Mariani, G.3    Mannucci, P.M.4
  • 11
    • 0031984017 scopus 로고    scopus 로고
    • Monoclonal anti-human factor VII antibody (B101/B1) which recognizes three dimensional structure near Arg at position 79 in1st EGF-like domain
    • Takamiya O. Monoclonal anti-human factor VII antibody (B101/B1) which recognizes three dimensional structure near Arg at position 79 in1st EGF-like domain. Thromb Haemost 1998; 79: 104-9.
    • (1998) Thromb Haemost , vol.79 , pp. 104-109
    • Takamiya, O.1
  • 12
    • 34447624435 scopus 로고    scopus 로고
    • Does the poor correlation between the hemorrhage symptom and the FVIIc of VII factor deficiency have the problem in the quality of the measurement?
    • Takamiya O. Does the poor correlation between the hemorrhage symptom and the FVIIc of VII factor deficiency have the problem in the quality of the measurement? Journal of the Japanese Society for Laboratory Hematology 2007; 8: 9-15.
    • (2007) Journal of the Japanese Society for Laboratory Hematology , vol.8 , pp. 9-15
    • Takamiya, O.1
  • 14
    • 34447642628 scopus 로고    scopus 로고
    • FVII Mutation Database. London, UK: The Haemostasis Research Group accessed 1 June 2007
    • FVII Mutation Database. London, UK: The Haemostasis Research Group, Medical Research Council Clinical Sciences Centre, 2004. http://europium.csc.mrc.ac.uk; accessed 1 June 2007.
    • (2004) Medical Research Council Clinical Sciences Centre
  • 15
    • 0019270967 scopus 로고
    • Factor assay (VIII and IX) results in the College of American Pathologists Survey Program (1976-1979)
    • Triplett DA, Kocoshis TA, Harms CS. Factor assay (VIII and IX) results in the College of American Pathologists Survey Program (1976-1979). Scand J Haematol Suppl 1980; 37: 116-29.
    • (1980) Scand J Haematol Suppl , vol.37 , pp. 116-129
    • Triplett, D.A.1    Kocoshis, T.A.2    Harms, C.S.3
  • 16
    • 0020603134 scopus 로고
    • Factor assay (VIII and IX) results in the College of American Pathologists Survey Program (1980-1982)
    • Christensen RL, Triplett DA. Factor assay (VIII and IX) results in the College of American Pathologists Survey Program (1980-1982). Am J Clin Pathol 1983; 4 (Suppl.): 633-42.
    • (1983) Am J Clin Pathol , vol.4 , Issue.SUPPL. , pp. 633-642
    • Christensen, R.L.1    Triplett, D.A.2
  • 17
    • 0026702675 scopus 로고
    • Factors affecting the performance of factor VIII coagulant activity assays
    • Arkin CF, Bovill EG, Brandt JT, Rock WA, Triplett DA. Factors affecting the performance of factor VIII coagulant activity assays. Results of proficiency surveys of the College of American Pathologists. Arch Pathol Lab Med 1992; 116: 908-15.
    • (1992) Arch Pathol Lab Med , vol.116 , pp. 908-915
    • Arkin, C.F.1    Bovill, E.G.2    Brandt, J.T.3    Rock, W.A.4    Triplett, D.A.5
  • 19
    • 0025871447 scopus 로고
    • Purification and characterization of factor VII 304-Gln: A variant molecule with reduced activity isolated from a clinically unaffected male
    • O'Brien DP, Gale KM, Anderson JS, McVey JH, Miller GJ, Meade TW, Tuddenham EG. Purification and characterization of factor VII 304-Gln: A variant molecule with reduced activity isolated from a clinically unaffected male. Blood 1991; 78: 132-14.
    • (1991) Blood , vol.78 , pp. 132-214
    • O'Brien, D.P.1    Gale, K.M.2    Anderson, J.S.3    McVey, J.H.4    Miller, G.J.5    Meade, T.W.6    Tuddenham, E.G.7
  • 20
    • 0028988004 scopus 로고
    • Factor VII Shinjo: A dysfunctional factor VII variant homozygous for the substitution Gln for Arg at position 79
    • Takamiya O, Abe S, Yoshioka A, Nakajima K, McVey JH, Tuddenham EG. Factor VII Shinjo: A dysfunctional factor VII variant homozygous for the substitution Gln for Arg at position 79. Haemostasis 1995; 25: 89-97.
    • (1995) Haemostasis , vol.25 , pp. 89-97
    • Takamiya, O.1    Abe, S.2    Yoshioka, A.3    Nakajima, K.4    McVey, J.H.5    Tuddenham, E.G.6
  • 21
    • 0029925105 scopus 로고    scopus 로고
    • Prothrombin time sensitivity and specificity to mild clotting factor deficiencies of the extrinsic pathway: Evaluation of eight commercial thromboplastins
    • Massignon D, Moulsma M, Bondon P, Debize G, Abidi H, Buttin T, Bon C, Pillonchery G, Coeur P. Prothrombin time sensitivity and specificity to mild clotting factor deficiencies of the extrinsic pathway: Evaluation of eight commercial thromboplastins. Thromb Haemost 1996; 75: 590-4.
    • (1996) Thromb Haemost , vol.75 , pp. 590-594
    • Massignon, D.1    Moulsma, M.2    Bondon, P.3    Debize, G.4    Abidi, H.5    Buttin, T.6    Bon, C.7    Pillonchery, G.8    Coeur, P.9
  • 23
    • 33745273595 scopus 로고    scopus 로고
    • Traces of factor VIIa modulate thromboplastin sensitivity to factors V, VII, X, and prothrombin
    • Smith SA, Comp PC, Morrissey JH. Traces of factor VIIa modulate thromboplastin sensitivity to factors V, VII, X, and prothrombin. J Thromb Haemost 2006; 4: 1553-8.
    • (2006) J Thromb Haemost , vol.4 , pp. 1553-1558
    • Smith, S.A.1    Comp, P.C.2    Morrissey, J.H.3
  • 24
    • 34447631628 scopus 로고
    • Problems of reference plasma in assay of coagulation factors; Is the assigned values of commercial standard plasma calibrated by WHO standard interchangeable to that of another one?
    • Takamiya O, Takeda Y, Kitagawa M. Problems of reference plasma in assay of coagulation factors; Is the assigned values of commercial standard plasma calibrated by WHO standard interchangeable to that of another one? Japanese Journal of Medical Thechnology 1995b; 44: 1516-21.
    • (1995) Japanese Journal of Medical Thechnology , vol.44 , pp. 1516-1521
    • Takamiya, O.1    Takeda, Y.2    Kitagawa, M.3
  • 25
    • 0029919365 scopus 로고    scopus 로고
    • Low plasma levels of factor VIIc and antigen are more strongly associated with the 10 base pair promoter (-323) insertion than the glutamine 353 variant
    • Humphries S, Temple A, Lane A, Green F, Cooper J, Miller G. Low plasma levels of factor VIIc and antigen are more strongly associated with the 10 base pair promoter (-323) insertion than the glutamine 353 variant. Thromb Haemost 1996; 75: 567-72.
    • (1996) Thromb Haemost , vol.75 , pp. 567-572
    • Humphries, S.1    Temple, A.2    Lane, A.3    Green, F.4    Cooper, J.5    Miller, G.6
  • 26
    • 0025860324 scopus 로고
    • A common genetic polymorphism associated with lower coagulation factor VII levels in healthy individuals
    • Green F, Kelleher C, Wilkes H, Temple A, Meade T, Humphries S. A common genetic polymorphism associated with lower coagulation factor VII levels in healthy individuals. Arterioscler Thromb 1991; 11: 540-6.
    • (1991) Arterioscler Thromb , vol.11 , pp. 540-546
    • Green, F.1    Kelleher, C.2    Wilkes, H.3    Temple, A.4    Meade, T.5    Humphries, S.6
  • 27
    • 0022479479 scopus 로고
    • Characterization and comparison of immune-depleted and hereditary factor-VII-deficient plasmas as substrate plasmas for factor VII assays
    • Brandt JT, Triplett DA, Fair DS. Characterization and comparison of immune-depleted and hereditary factor-VII-deficient plasmas as substrate plasmas for factor VII assays. Am J Clin Pathol 1986; 85: 583-9.
    • (1986) Am J Clin Pathol , vol.85 , pp. 583-589
    • Brandt, J.T.1    Triplett, D.A.2    Fair, D.S.3
  • 29
    • 33644989357 scopus 로고    scopus 로고
    • Accuracy of FVIII: C assay by one-stage method can be improved using hemophilic plasma as diluent
    • Cinotti S, Paladino E, Morfini M. Accuracy of FVIII: C assay by one-stage method can be improved using hemophilic plasma as diluent. J Thromb Haemost 2006; 4: 828-33.
    • (2006) J Thromb Haemost , vol.4 , pp. 828-833
    • Cinotti, S.1    Paladino, E.2    Morfini, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.