메뉴 건너뛰기




Volumn 120, Issue 4, 2007, Pages 471-476

Validation of a new D-dimer microparticle enzyme immunoassay (AxSYM D-Dimer) in patients with suspected pulmonary embolism (PE)

Author keywords

D dimer; Pulmonary embolism; ROC curve; Sensitivity; Specificity

Indexed keywords

D DIMER;

EID: 34447632831     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2006.11.005     Document Type: Article
Times cited : (20)

References (25)
  • 1
    • 0023883101 scopus 로고
    • Monoclonal antibodies to crosslinked fibrin degradation products (XL-FDP). II. Evaluation in a variety of clinical conditions
    • Gaffney P.J., Creighton L.J., Callus M., and Thorpe R. Monoclonal antibodies to crosslinked fibrin degradation products (XL-FDP). II. Evaluation in a variety of clinical conditions. Br J Haematol 68 1 (1988) 91-96
    • (1988) Br J Haematol , vol.68 , Issue.1 , pp. 91-96
    • Gaffney, P.J.1    Creighton, L.J.2    Callus, M.3    Thorpe, R.4
  • 2
    • 1642333115 scopus 로고    scopus 로고
    • D-dimer for suspected pulmonary embolism: whom should we test?
    • Perrier A. D-dimer for suspected pulmonary embolism: whom should we test?. Chest 125 3 (2004) 807-809
    • (2004) Chest , vol.125 , Issue.3 , pp. 807-809
    • Perrier, A.1
  • 3
    • 0033573784 scopus 로고    scopus 로고
    • Non-invasive diagnosis of venous thromboembolism in outpatients
    • Perrier A., Desmarais S., Miron M.J., de M.P., Lepage R., Slosman D., et al. Non-invasive diagnosis of venous thromboembolism in outpatients. Lancet 353 9148 (1999) 190-195
    • (1999) Lancet , vol.353 , Issue.9148 , pp. 190-195
    • Perrier, A.1    Desmarais, S.2    Miron, M.J.3    de, M.P.4    Lepage, R.5    Slosman, D.6
  • 4
    • 10744219980 scopus 로고    scopus 로고
    • Diagnosing pulmonary embolism in outpatients with clinical assessment, D-dimer measurement, venous ultrasound, and helical computed tomography: a multicenter management study
    • Perrier A., Roy P.M., Aujesky D., Chagnon I., Howarth N., Gourdier A.L., et al. Diagnosing pulmonary embolism in outpatients with clinical assessment, D-dimer measurement, venous ultrasound, and helical computed tomography: a multicenter management study. Am J Med 116 5 (2004) 291-299
    • (2004) Am J Med , vol.116 , Issue.5 , pp. 291-299
    • Perrier, A.1    Roy, P.M.2    Aujesky, D.3    Chagnon, I.4    Howarth, N.5    Gourdier, A.L.6
  • 5
    • 15944363377 scopus 로고    scopus 로고
    • An evaluation of rapid D-dimer assays for the exclusion of deep vein thrombosis
    • Gardiner C., Pennaneac'h C., Walford C., Machin S.J., and Mackie I.J. An evaluation of rapid D-dimer assays for the exclusion of deep vein thrombosis. Br J Haematol 128 6 (2005) 842-848
    • (2005) Br J Haematol , vol.128 , Issue.6 , pp. 842-848
    • Gardiner, C.1    Pennaneac'h, C.2    Walford, C.3    Machin, S.J.4    Mackie, I.J.5
  • 6
    • 0035074668 scopus 로고    scopus 로고
    • The Fibrin Assay Comparison Trial (FACT): evaluation of 23 quantitative D-dimer assays as basis for the development of D-dimer calibrators. FACT study group
    • Dempfle C.E., Zips S., Ergul H., and Heene D.L. The Fibrin Assay Comparison Trial (FACT): evaluation of 23 quantitative D-dimer assays as basis for the development of D-dimer calibrators. FACT study group. Thromb Haemost 85 4 (2001) 671-678
    • (2001) Thromb Haemost , vol.85 , Issue.4 , pp. 671-678
    • Dempfle, C.E.1    Zips, S.2    Ergul, H.3    Heene, D.L.4
  • 7
    • 0033890248 scopus 로고    scopus 로고
    • D-dimer for the diagnosis of venous thromboembolism
    • Anderson D.R., and Wells P.S. D-dimer for the diagnosis of venous thromboembolism. Curr Opin Hematol 7 5 (2000) 296-301
    • (2000) Curr Opin Hematol , vol.7 , Issue.5 , pp. 296-301
    • Anderson, D.R.1    Wells, P.S.2
  • 8
    • 0033950043 scopus 로고    scopus 로고
    • Exclusion of deep venous thrombosis with D-dimer testing-comparison of 13 D-dimer methods in 99 outpatients suspected of deep venous thrombosis using venography as reference standard
    • van der Graff F., van den Borne H., van der Kolk M., de Wild P.J., Janssen G.W., and van Uum S.H. Exclusion of deep venous thrombosis with D-dimer testing-comparison of 13 D-dimer methods in 99 outpatients suspected of deep venous thrombosis using venography as reference standard. Thromb Haemost 83 2 (2000) 191-198
    • (2000) Thromb Haemost , vol.83 , Issue.2 , pp. 191-198
    • van der Graff, F.1    van den Borne, H.2    van der Kolk, M.3    de Wild, P.J.4    Janssen, G.W.5    van Uum, S.H.6
  • 9
    • 28444442978 scopus 로고    scopus 로고
    • Performances of the HemosIL D-dimer HS assay for the exclusion of venous thromboembolism
    • Moerloose P., Vanrusselt M., Reber G., and Arnout J. Performances of the HemosIL D-dimer HS assay for the exclusion of venous thromboembolism. J Thromb Haemost 3 10 (2005) 2361-2363
    • (2005) J Thromb Haemost , vol.3 , Issue.10 , pp. 2361-2363
    • Moerloose, P.1    Vanrusselt, M.2    Reber, G.3    Arnout, J.4
  • 10
    • 0037120965 scopus 로고    scopus 로고
    • Normal D-dimer levels in emergency department patients suspected of acute pulmonary embolism
    • Dunn K.L., Wolf J.P., Dorfman D.M., Fitzpatrick P., Baker J.L., and Goldhaber S.Z. Normal D-dimer levels in emergency department patients suspected of acute pulmonary embolism. J Am Coll Cardiol 40 8 (2002) 1475-1478
    • (2002) J Am Coll Cardiol , vol.40 , Issue.8 , pp. 1475-1478
    • Dunn, K.L.1    Wolf, J.P.2    Dorfman, D.M.3    Fitzpatrick, P.4    Baker, J.L.5    Goldhaber, S.Z.6
  • 11
    • 14644421482 scopus 로고    scopus 로고
    • Diagnosis accuracy of a new challenger for thrombosis exclusion, the Stratus CS DDMR
    • Freyburger G., Reboul M.P., Labrouche S., Saillour F., and Grenier N. Diagnosis accuracy of a new challenger for thrombosis exclusion, the Stratus CS DDMR. Clin Chim Acta 354 1-2 (2005) 181-189
    • (2005) Clin Chim Acta , vol.354 , Issue.1-2 , pp. 181-189
    • Freyburger, G.1    Reboul, M.P.2    Labrouche, S.3    Saillour, F.4    Grenier, N.5
  • 12
    • 14144255255 scopus 로고    scopus 로고
    • Exclusion of venous thromboembolism: evaluation of D-Dimer PLUS for the quantitative determination of D-dimer
    • Vermeer H.J., Ypma P., van Strijen M.J., Muradin A.A., Hudig F., Jansen R.W., et al. Exclusion of venous thromboembolism: evaluation of D-Dimer PLUS for the quantitative determination of D-dimer. Thromb Res 115 5 (2005) 381-386
    • (2005) Thromb Res , vol.115 , Issue.5 , pp. 381-386
    • Vermeer, H.J.1    Ypma, P.2    van Strijen, M.J.3    Muradin, A.A.4    Hudig, F.5    Jansen, R.W.6
  • 13
    • 19344378049 scopus 로고    scopus 로고
    • Performance of the automated and rapid STA Liatest D-dimer on the STA-R analyzer
    • Waser G., Kathriner S., and Wuillemin W.A. Performance of the automated and rapid STA Liatest D-dimer on the STA-R analyzer. Thromb Res 116 2 (2005) 165-170
    • (2005) Thromb Res , vol.116 , Issue.2 , pp. 165-170
    • Waser, G.1    Kathriner, S.2    Wuillemin, W.A.3
  • 14
    • 30444451951 scopus 로고    scopus 로고
    • Management of suspected pulmonary embolism (PE) by D-dimer and multi-slice computed tomography in outpatients: an outcome study
    • Ghanima W., Almaas V., Aballi S., Dorje C., Nielssen B.E., Holmen L.O., et al. Management of suspected pulmonary embolism (PE) by D-dimer and multi-slice computed tomography in outpatients: an outcome study. J Thromb Haemost 3 9 (2005) 1926-1932
    • (2005) J Thromb Haemost , vol.3 , Issue.9 , pp. 1926-1932
    • Ghanima, W.1    Almaas, V.2    Aballi, S.3    Dorje, C.4    Nielssen, B.E.5    Holmen, L.O.6
  • 15
    • 33644817494 scopus 로고    scopus 로고
    • The performance of STA-Liatest D-dimer assay in out-patients with suspected pulmonary embolism
    • Ghanima W., Abdelnoor M., Mowinckel M.C., and Sandset P.M. The performance of STA-Liatest D-dimer assay in out-patients with suspected pulmonary embolism. Br J Haematol 132 2 (2006) 210-215
    • (2006) Br J Haematol , vol.132 , Issue.2 , pp. 210-215
    • Ghanima, W.1    Abdelnoor, M.2    Mowinckel, M.C.3    Sandset, P.M.4
  • 17
    • 0032899015 scopus 로고    scopus 로고
    • Venous thromboembolism
    • Hyers T.M. Venous thromboembolism. Am J Respir Crit Care Med 159 1 (1999) 1-14
    • (1999) Am J Respir Crit Care Med , vol.159 , Issue.1 , pp. 1-14
    • Hyers, T.M.1
  • 18
    • 0032126661 scopus 로고    scopus 로고
    • A new quantitative D-dimer assay appropriate in emergency: reliability of the assay for pulmonary embolism exclusion diagnosis
    • Duet M., Benelhadj S., Kedra W., Vilain D., Ajzenberg C., Elkharrat D., et al. A new quantitative D-dimer assay appropriate in emergency: reliability of the assay for pulmonary embolism exclusion diagnosis. Thromb Res 91 1 (1998) 1-5
    • (1998) Thromb Res , vol.91 , Issue.1 , pp. 1-5
    • Duet, M.1    Benelhadj, S.2    Kedra, W.3    Vilain, D.4    Ajzenberg, C.5    Elkharrat, D.6
  • 19
    • 0034023924 scopus 로고    scopus 로고
    • Incidence of venous thromboembolism: a community-based study in Western France. EPI-GETBP Study Group. Groupe d'Etude de la Thrombose de Bretagne Occidentale
    • Oger E. Incidence of venous thromboembolism: a community-based study in Western France. EPI-GETBP Study Group. Groupe d'Etude de la Thrombose de Bretagne Occidentale. Thromb Haemost 83 5 (2000) 657-660
    • (2000) Thromb Haemost , vol.83 , Issue.5 , pp. 657-660
    • Oger, E.1
  • 20
    • 20244387564 scopus 로고    scopus 로고
    • Multidetector-row computed tomography in suspected pulmonary embolism
    • Perrier A., Roy P.M., Sanchez O., Le G.G., Meyer G., Gourdier A.L., et al. Multidetector-row computed tomography in suspected pulmonary embolism. N Engl J Med 352 17 (2005) 1760-1768
    • (2005) N Engl J Med , vol.352 , Issue.17 , pp. 1760-1768
    • Perrier, A.1    Roy, P.M.2    Sanchez, O.3    Le, G.G.4    Meyer, G.5    Gourdier, A.L.6
  • 21
    • 0033405941 scopus 로고    scopus 로고
    • Plasma D-dimers: comparison of ELISA with a new, rapid, quantitative latex assay
    • Barro C., Bosson J.L., Pernod G., Carpentier P.H., and Polack B. Plasma D-dimers: comparison of ELISA with a new, rapid, quantitative latex assay. Clin Lab Haematol 21 5 (1999) 363-364
    • (1999) Clin Lab Haematol , vol.21 , Issue.5 , pp. 363-364
    • Barro, C.1    Bosson, J.L.2    Pernod, G.3    Carpentier, P.H.4    Polack, B.5
  • 23
    • 0038471175 scopus 로고    scopus 로고
    • British Thoracic Society guidelines for the management of suspected acute pulmonary embolism
    • British Thoracic Society guidelines for the management of suspected acute pulmonary embolism. Thorax 58 6 (2003) 470-483
    • (2003) Thorax , vol.58 , Issue.6 , pp. 470-483
  • 24
    • 10344224024 scopus 로고    scopus 로고
    • Clinical usefulness of D-dimer depending on clinical probability and cutoff value in outpatients with suspected pulmonary embolism
    • Righini M., Aujesky D., Roy P.M., Cornuz J., de M.P., Bounameaux H., et al. Clinical usefulness of D-dimer depending on clinical probability and cutoff value in outpatients with suspected pulmonary embolism. Arch Intern Med 164 22 (2004) 2483-2487
    • (2004) Arch Intern Med , vol.164 , Issue.22 , pp. 2483-2487
    • Righini, M.1    Aujesky, D.2    Roy, P.M.3    Cornuz, J.4    de, M.P.5    Bounameaux, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.