메뉴 건너뛰기




Volumn 334, Issue 1, 2007, Pages 53-56

Blood volume measurement as a tool in diagnosing syncope

Author keywords

Blood volume; Measurement; Syncope

Indexed keywords

ADOLESCENT; ADULT; AGED; BLOOD PRESSURE; BLOOD VOLUME; CONFERENCE PAPER; CONTROLLED STUDY; CORRELATION ANALYSIS; FEMALE; HEART INDEX; HEART RATE; HEMATOCRIT; HUMAN; ISOTOPE LABELING; MAJOR CLINICAL STUDY; MALE; SYNCOPE;

EID: 34447557904     PISSN: 00029629     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAJ.0b013e318063c6f7     Document Type: Conference Paper
Times cited : (15)

References (16)
  • 2
    • 0035881070 scopus 로고    scopus 로고
    • How often does a standard evaluation of syncope identify an underlying etiology?
    • Sarasin FP, Louis-Simonet M, Carballo D, et al. How often does a standard evaluation of syncope identify an underlying etiology? Am J Med 2001;11:177-84.
    • (2001) Am J Med , vol.11 , pp. 177-184
    • Sarasin, F.P.1    Louis-Simonet, M.2    Carballo, D.3
  • 3
    • 0036282941 scopus 로고    scopus 로고
    • Strategy for the management of vasovagal syncope
    • Bloomfield DM. Strategy for the management of vasovagal syncope. Drugs Aging 2002;19:179-202.
    • (2002) Drugs Aging , vol.19 , pp. 179-202
    • Bloomfield, D.M.1
  • 4
    • 0035090923 scopus 로고    scopus 로고
    • Dysautonomia and neurocardiogenic syncope
    • McLeod KA. Dysautonomia and neurocardiogenic syncope. Curr Opin Cardiol 2001;16:92-6.
    • (2001) Curr Opin Cardiol , vol.16 , pp. 92-96
    • McLeod, K.A.1
  • 5
    • 0033592525 scopus 로고    scopus 로고
    • Putting it together: A new treatment algorithm for vasovagal syncope and related disorders
    • Bloomfield DM, Sheldon R, Grubb BP, et al. Putting it together: a new treatment algorithm for vasovagal syncope and related disorders. Am J Cardiol 1999;84:33Q-9Q.
    • (1999) Am J Cardiol , vol.84
    • Bloomfield, D.M.1    Sheldon, R.2    Grubb, B.P.3
  • 6
    • 0037420113 scopus 로고    scopus 로고
    • selective use of diagnostic tests in patients with syncope of unknown cause
    • Garcia-Civera R, Ruiz-Granell R, Morell-Cabedo S, et al. selective use of diagnostic tests in patients with syncope of unknown cause. J Am Coll Cardiol 2003;41:787-90.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 787-790
    • Garcia-Civera, R.1    Ruiz-Granell, R.2    Morell-Cabedo, S.3
  • 8
    • 2342572772 scopus 로고    scopus 로고
    • Relation of unrecognized hypervolemia in chronic heart failure to clinical status, hemodynamics, and patient outcomes
    • Androne AS, Hryniewicz K, Hudaihed A, et al. Relation of unrecognized hypervolemia in chronic heart failure to clinical status, hemodynamics, and patient outcomes. Am J Cardiol 2004;93:1254-9.
    • (2004) Am J Cardiol , vol.93 , pp. 1254-1259
    • Androne, A.S.1    Hryniewicz, K.2    Hudaihed, A.3
  • 9
    • 0037458102 scopus 로고    scopus 로고
    • Hemodilution is common in patients with advanced heart failure
    • Androne AS, Katz SD, Lund L, et al. Hemodilution is common in patients with advanced heart failure. Circulation 2003;107:226-9.
    • (2003) Circulation , vol.107 , pp. 226-229
    • Androne, A.S.1    Katz, S.D.2    Lund, L.3
  • 10
    • 0036860372 scopus 로고    scopus 로고
    • Shevde K, Pagala M, Tyagaraj C, et al. Preoperative blood deficit influences blood transfusion requirements in females and males undergoing coronary bypass graft surgery. J Clin Anesth 2002;14:000.
    • Shevde K, Pagala M, Tyagaraj C, et al. Preoperative blood volume deficit influences blood transfusion requirements in females and males undergoing coronary bypass graft surgery. J Clin Anesth 2002;14:000.
  • 11
    • 0019314109 scopus 로고
    • Recommended methods for measurement of red-cell and plasma volume: International Committee for Standardization in Haematology
    • Recommended methods for measurement of red-cell and plasma volume: International Committee for Standardization in Haematology. J Nucl Med 1980;21:793-800.
    • (1980) J Nucl Med , vol.21 , pp. 793-800
  • 12
    • 34447498450 scopus 로고    scopus 로고
    • Comparison of Red Cell and Whole Blood Volume as Performed Using Both Chromium-51 Tagged Red Cells and Iodine-125 Tagged Albumin and Using I-131 Tagged Albumin and Extrapolated Red Cell Volume
    • Presented at the, Toronto, Canada, June, Poster Presentation
    • Dworkin H, Premo M, Dees S. Comparison of Red Cell and Whole Blood Volume as Performed Using Both Chromium-51 Tagged Red Cells and Iodine-125 Tagged Albumin and Using I-131 Tagged Albumin and Extrapolated Red Cell Volume. Presented at the June 2005 Annual Meeting of the Society of Nuclear Medicine, Toronto, Canada, June 2005. (Poster Presentation).
    • (2005) June 2005 Annual Meeting of the Society of Nuclear Medicine
    • Dworkin, H.1    Premo, M.2    Dees, S.3
  • 13
    • 0036872294 scopus 로고    scopus 로고
    • Correlation of blood volume values and pulmonary artery catheter measurements
    • Alrawi SJ, Miranda LS, Cunningham JN Jr, et al. Correlation of blood volume values and pulmonary artery catheter measurements. Saudi Med J 2002;23:1367-72.
    • (2002) Saudi Med J , vol.23 , pp. 1367-1372
    • Alrawi, S.J.1    Miranda, L.S.2    Cunningham Jr, J.N.3
  • 14
    • 0017700829 scopus 로고
    • Prediction of the normal blood volume
    • Feldschuh J, Enson Y. Prediction of the normal blood volume. Circulation 1977;56:605-11.
    • (1977) Circulation , vol.56 , pp. 605-611
    • Feldschuh, J.1    Enson, Y.2
  • 15
    • 0018571579 scopus 로고
    • Automated computer program for radionuclide cardiac output determination
    • Fouad FM, Houser T, MacIntyre WJ, et al. Automated computer program for radionuclide cardiac output determination. J Nucl Med 1979;20:1301-7.
    • (1979) J Nucl Med , vol.20 , pp. 1301-1307
    • Fouad, F.M.1    Houser, T.2    MacIntyre, W.J.3
  • 16
    • 0019812645 scopus 로고
    • Noninvasive measurement of cardiopulmonary blood volume: Evaluation of the centriod method
    • Fouad FM, MacIntyre WJ, Tarazi RC. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centriod method. J Nucl Med 1981;22:205-11.
    • (1981) J Nucl Med , vol.22 , pp. 205-211
    • Fouad, F.M.1    MacIntyre, W.J.2    Tarazi, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.