메뉴 건너뛰기




Volumn 46, Issue 3, 2007, Pages 47-52

Establishment of blood analyte intervals for laboratory mice and rats by use of a portable clinical analyzer

Author keywords

[No Author keywords available]

Indexed keywords

CHLORIDE; GLUCOSE; HEMOGLOBIN; HEPARIN; LITHIUM; NITROGEN; POTASSIUM; SODIUM; UREA;

EID: 34447550403     PISSN: 15596109     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0032917896 scopus 로고    scopus 로고
    • The portable laboratory: An evaluation of the accuracy and reproducibility of i-STAT
    • Bingham D, Kendall J, Clancy M. 1999. The portable laboratory: an evaluation of the accuracy and reproducibility of i-STAT Ann Clin Biochem 36(Pt 1):66-71.
    • (1999) Ann Clin Biochem , vol.36 , Issue.PART 1 , pp. 66-71
    • Bingham, D.1    Kendall, J.2    Clancy, M.3
  • 4
    • 34447548313 scopus 로고    scopus 로고
    • Personal communication
    • DeNicola DB. 2006. Personal communication.
    • (2006)
    • DeNicola, D.B.1
  • 5
    • 34447541816 scopus 로고    scopus 로고
    • online, The R package for statistical computing [cited 26 Mar 2006, Available at
    • Department of Statistics and Mathematics [online]. The R package for statistical computing [cited 26 Mar 2006]. Available at http://www.r- project.org/.
    • Department of Statistics and Mathematics
  • 6
    • 0027410804 scopus 로고
    • Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer
    • Erickson KA, Wilding P. 1993. Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer. Clin Chem 39:283-287.
    • (1993) Clin Chem , vol.39 , pp. 283-287
    • Erickson, K.A.1    Wilding, P.2
  • 8
    • 0345765237 scopus 로고    scopus 로고
    • Determination of agreement between laboratory instruments
    • Gray TE, Pratt MC, Cusick PK. 1999. Determination of agreement between laboratory instruments. Contemp Top Lab Anim Sci 38(2):56-59.
    • (1999) Contemp Top Lab Anim Sci , vol.38 , Issue.2 , pp. 56-59
    • Gray, T.E.1    Pratt, M.C.2    Cusick, P.K.3
  • 9
    • 0032161572 scopus 로고    scopus 로고
    • Evaluation of a portable clinical analyzer in a veterinary hospital setting
    • Grosenbaugh DA, Gadawski JE, Muir WW. 1998. Evaluation of a portable clinical analyzer in a veterinary hospital setting. J Am Vet Med Assoc 213:691-694.
    • (1998) J Am Vet Med Assoc , vol.213 , pp. 691-694
    • Grosenbaugh, D.A.1    Gadawski, J.E.2    Muir, W.W.3
  • 11
    • 0027255920 scopus 로고
    • Analytical evaluation of i-STAT portable clinical analyzer and use by nonlaboratory healthcare professionals
    • Jacobs E, Vadasdi E, Sarkozi L, Colman N. 1993. Analytical evaluation of i-STAT portable clinical analyzer and use by nonlaboratory healthcare professionals. Clin Chem 39:1069-1074.
    • (1993) Clin Chem , vol.39 , pp. 1069-1074
    • Jacobs, E.1    Vadasdi, E.2    Sarkozi, L.3    Colman, N.4
  • 12
    • 1642322705 scopus 로고    scopus 로고
    • Ethanol interferes with the measurement of extracellular ionized calcium
    • Keiver K. 2004. Ethanol interferes with the measurement of extracellular ionized calcium. Alcohol Clin Exp Res 28:153-159.
    • (2004) Alcohol Clin Exp Res , vol.28 , pp. 153-159
    • Keiver, K.1
  • 13
    • 33646526255 scopus 로고    scopus 로고
    • Ethanol administration results in a prolonged decrease in blood ionized calcium levels in the rat
    • Keiver K, Duggal S, Simpson ME. 2005. Ethanol administration results in a prolonged decrease in blood ionized calcium levels in the rat. Alcohol 37:173-178.
    • (2005) Alcohol , vol.37 , pp. 173-178
    • Keiver, K.1    Duggal, S.2    Simpson, M.E.3
  • 14
    • 0036751303 scopus 로고    scopus 로고
    • Blood values of juvenile northern elephant seals (Mirounga angustirostris) obtained using a portable clinical analyzer
    • Larsen RS, Haulena M, Grindem CB, Gulland FM. 2002. Blood values of juvenile northern elephant seals (Mirounga angustirostris) obtained using a portable clinical analyzer. Vet Clin Pathol 31:106-110.
    • (2002) Vet Clin Pathol , vol.31 , pp. 106-110
    • Larsen, R.S.1    Haulena, M.2    Grindem, C.B.3    Gulland, F.M.4
  • 15
    • 0032528749 scopus 로고    scopus 로고
    • Use of a handheld device for analysis of blood electrolyte concentrations and blood gas partial pressures in dogs and horses
    • Looney AL, Ludders J, Erb HN, Gleed R, Moon P. 1998. Use of a handheld device for analysis of blood electrolyte concentrations and blood gas partial pressures in dogs and horses. J Am Vet Med Assoc 213:526-530.
    • (1998) J Am Vet Med Assoc , vol.213 , pp. 526-530
    • Looney, A.L.1    Ludders, J.2    Erb, H.N.3    Gleed, R.4    Moon, P.5
  • 16
    • 0033188150 scopus 로고    scopus 로고
    • Clinical pathology and sample collection in the laboratory rodent
    • vi
    • McClure DE. 1999. Clinical pathology and sample collection in the laboratory rodent. Vet Clin North Am Exot Anim Pract 2:565-590, vi.
    • (1999) Vet Clin North Am Exot Anim Pract , vol.2 , pp. 565-590
    • McClure, D.E.1
  • 17
    • 0028985807 scopus 로고
    • Evaluation of the i-STAT system: A portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit
    • Mock T, Morrison D, Yatscoff R. 1995. Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit. Clin Biochem 28:187-192.
    • (1995) Clin Biochem , vol.28 , pp. 187-192
    • Mock, T.1    Morrison, D.2    Yatscoff, R.3
  • 18
    • 0003673874 scopus 로고    scopus 로고
    • Guide for the care and use of laboratory animals. Washington DC, National Academy Press
    • National Research Council. 1996. Guide for the care and use of laboratory animals. Washington (DC): National Academy Press.
    • (1996) National Research Council
  • 21
    • 33845589226 scopus 로고    scopus 로고
    • Effects of duration of capture and sample handling on critical care blood analytes in free-ranging bottlenose dolphins
    • Varela RA, Schwacke L, Fair PA, Bossart GD. 2006. Effects of duration of capture and sample handling on critical care blood analytes in free-ranging bottlenose dolphins. J Am Vet Med Assoc 229:1955.
    • (2006) J Am Vet Med Assoc , vol.229 , pp. 1955
    • Varela, R.A.1    Schwacke, L.2    Fair, P.A.3    Bossart, G.D.4
  • 22
    • 0036700438 scopus 로고    scopus 로고
    • The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs
    • Verwaerde P, Malet C, Lagente M, de la Farge F, Braun JP. 2002. The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs. Res Vet Sci 73:71-75.
    • (2002) Res Vet Sci , vol.73 , pp. 71-75
    • Verwaerde, P.1    Malet, C.2    Lagente, M.3    de la Farge, F.4    Braun, J.P.5
  • 23
    • 0344707416 scopus 로고    scopus 로고
    • Establishing reference intervals: Health as a relative concept
    • Walton RM. 2001. Establishing reference intervals: health as a relative concept. Semin Avian Exotic Pet Med 10:66-71.
    • (2001) Semin Avian Exotic Pet Med , vol.10 , pp. 66-71
    • Walton, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.