Volumn 13, Issue 2, 2007, Pages 43-48

ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation

Author keywords

Carryover; Comparability; Doping control; ISO IEC 17025; Linearity; Precision; Stability; Sysmex R 500 hematology reticulocyte analyzer; Sysmex SE 9500; Uncertainty

Indexed keywords

ACCREDITATION; ANALYSIS OF VARIANCE; ARTICLE; AUTOANALYZER; BLOOD ANALYSIS; CALIBRATION; CONTROLLED STUDY; CORRELATION COEFFICIENT; DOPING; ERYTHROCYTE COUNT; HUMAN; HUMAN CELL; INSTRUMENT VALIDATION; INTERMETHOD COMPARISON; LOW TEMPERATURE; MEDICAL ASSESSMENT; MEDICAL INSTRUMENTATION; PORTABLE EQUIPMENT; REGRESSION ANALYSIS; RETICULOCYTE COUNT; ROOM TEMPERATURE; THERMOSTABILITY; VALIDATION PROCESS;

EID: 34447531760     PISSN: 10802924     EISSN: None     Source Type: Journal    
DOI: 10.1532/LH96.06046     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 34447568644 scopus 로고    scopus 로고
    • ISO/IEC 17025:2005, General Requirements for the Competence of Calibration and Testing Laboratories, www.iso.org.
    • ISO/IEC 17025:2005, General Requirements for the Competence of Calibration and Testing Laboratories, www.iso.org.
  • 3
    • 33645392494 scopus 로고    scopus 로고
    • A third generation approach to detect erythropoietin abuse in athletes
    • Sharpe K, Ashenden MJ, Schumacher YO. A third generation approach to detect erythropoietin abuse in athletes. Haematologica. 2006;91:356-363.
    • (2006) Haematologica , vol.91 , pp. 356-363
    • Sharpe, K.1    Ashenden, M.J.2    Schumacher, Y.O.3
  • 4
    • 0036125472 scopus 로고    scopus 로고
    • Hematology parameters: Usefulness and limitations in monitoring red cell production
    • d'Onofrio G. Hematology parameters: usefulness and limitations in monitoring red cell production. Lab Hematol. 2002;8:46-47.
    • (2002) Lab Hematol , vol.8 , pp. 46-47
    • d'Onofrio, G.1
  • 5
    • 34447571102 scopus 로고    scopus 로고
    • Erythropoietin abuse in sport
    • Robinson N. Erythropoietin abuse in sport. Sysmex J Int. 2003;13:75-77.
    • (2003) Sysmex J Int , vol.13 , pp. 75-77
    • Robinson, N.1
  • 6
    • 34447535706 scopus 로고    scopus 로고
    • Sysmex America hematology analyser. Diagnostic instrument of choice for UCI cycling event
    • Giles I, Reinecke T. Sysmex America hematology analyser. Diagnostic instrument of choice for UCI cycling event. Sysmex J Int. 2005;152:71-75.
    • (2005) Sysmex J Int , vol.152 , pp. 71-75
    • Giles, I.1    Reinecke, T.2
  • 7
    • 34447574106 scopus 로고    scopus 로고
    • Evaluation of the Sysmex R-500 Automated Reticulocyte Analyser
    • Pollard Y, D. Grant. Evaluation of the Sysmex R-500 Automated Reticulocyte Analyser. Sysmex J Int. 1999;47:79-81.
    • (1999) Sysmex J Int , vol.47 , pp. 79-81
    • Pollard, Y.1    Grant, D.2
  • 8
    • 0035234204 scopus 로고    scopus 로고
    • Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analysers: An NCCLS-ICSH approach
    • Buttarello M, Bulian P, Farina G, et al. Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analysers: an NCCLS-ICSH approach. Am J Clin Pathol. 2001;115:100-111.
    • (2001) Am J Clin Pathol , vol.115 , pp. 100-111
    • Buttarello, M.1    Bulian, P.2    Farina, G.3
  • 9
    • 0028292764 scopus 로고
    • Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications
    • International Council for Standardisation in Haematology Expert Panel on Cytometry
    • International Council for Standardisation in Haematology Expert Panel on Cytometry. Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. Clin Lab Haematol. 1994;16:157-174.
    • (1994) Clin Lab Haematol , vol.16 , pp. 157-174
  • 10
    • 34447568643 scopus 로고    scopus 로고
    • European Co-operation for Accreditation. www.european-accreditation.org (eurachem.org/measurementuncertainty).
    • European Co-operation for Accreditation. www.european-accreditation.org (eurachem.org/measurementuncertainty).
  • 12
    • 34447579371 scopus 로고    scopus 로고
    • The trend of external quality assessment in Europe
    • Lewis SM. The trend of external quality assessment in Europe. Sysmex J Int. 1998;8:67-71.
    • (1998) Sysmex J Int , vol.8 , pp. 67-71
    • Lewis, S.M.1
  • 13
    • 34447577120 scopus 로고    scopus 로고
    • IQAS - the new approach to a total quality assurance system
    • Reinecke T. Sysmex IQAS - the new approach to a total quality assurance system. Sysmex J Int. 1998;8:86-90.
    • (1998) Sysmex J Int , vol.8 , pp. 86-90
    • Sysmex, R.T.1
  • 14
    • 34447548002 scopus 로고    scopus 로고
    • Sysmex R-500 Operators Manual. Sysmex Corporation, Kobe, Japan. 1998;1-11.
    • Sysmex R-500 Operators Manual. Sysmex Corporation, Kobe, Japan. 1998;1-11.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.