메뉴 건너뛰기




Volumn 21, Issue 6, 2007, Pages 414-417

Removal of an iliosacral screw entrapping the L5 nerve root after failed posterior pelvic ring fixation: A case report

Author keywords

Iliosacral screw complications; Pelvic ring disruptions; Percutaneous fixation of pelvic ring injuries

Indexed keywords

ADULT; ARTICLE; BONE SCREW; CASE REPORT; DEBRIDEMENT; DEVICE REMOVAL; FRACTURE FIXATION; HUMAN; JOINT DISLOCATION; LUMBAR SPINAL CORD; MALE; NERVE COMPRESSION; NERVE ROOT; OPEN REDUCTION; PELVIS FRACTURE; PERIPHERAL NERVE INJURY; PLATE FIXATION; PRIORITY JOURNAL; RADICULOPATHY; SACROILIAC JOINT; TREATMENT OUTCOME;

EID: 34447340908     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3180cab6b5     Document Type: Article
Times cited : (23)

References (19)
  • 1
    • 33745890788 scopus 로고    scopus 로고
    • Internal fixation of the injured pelvic ring
    • Tile M, Helfet DL, Kellam JF, 3rd ed. Philadelphia: Lippincott Williams and Wilkins;
    • Moed BR, Kellam JF, McLaren A, et al. Internal fixation of the injured pelvic ring. In: Tile M, Helfet DL, Kellam JF. Fractures of the pelvis and acetabulum. 3rd ed. Philadelphia: Lippincott Williams and Wilkins; 2003:217-293.
    • (2003) Fractures of the pelvis and acetabulum , pp. 217-293
    • Moed, B.R.1    Kellam, J.F.2    McLaren, A.3
  • 2
    • 0029314802 scopus 로고
    • Early results of percutaneous iliosacral screws placed with the patient in the supine position
    • Routt ML Jr, Kregor PJ, Simonian PT, et al. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9:207-214.
    • (1995) J Orthop Trauma , vol.9 , pp. 207-214
    • Routt Jr, M.L.1    Kregor, P.J.2    Simonian, P.T.3
  • 3
    • 0028606018 scopus 로고
    • Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation
    • Simonian PT, Routt ML Jr, Harrington RM, et al. Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation. Clin Orthop Relat Res. 1994;309:245-256.
    • (1994) Clin Orthop Relat Res , vol.309 , pp. 245-256
    • Simonian, P.T.1    Routt Jr, M.L.2    Harrington, R.M.3
  • 4
    • 0042474433 scopus 로고    scopus 로고
    • Biomechanical comparison of posterior pelvic ring fixation
    • Yinger K, Scalise J, Olson SA, et al. Biomechanical comparison of posterior pelvic ring fixation. J Orthop Trauma. 2003;17:481-487.
    • (2003) J Orthop Trauma , vol.17 , pp. 481-487
    • Yinger, K.1    Scalise, J.2    Olson, S.A.3
  • 5
    • 0030965034 scopus 로고    scopus 로고
    • Morphologic considerations of the first sacral pedicle for iliosacral screw placement
    • Ebraheim NA, Xu R, Biyani A, et al. Morphologic considerations of the first sacral pedicle for iliosacral screw placement. Spine. 1997;22:841.
    • (1997) Spine , vol.22 , pp. 841
    • Ebraheim, N.A.1    Xu, R.2    Biyani, A.3
  • 6
    • 0029789346 scopus 로고    scopus 로고
    • Proximity of iliosacral screws to neurovascular structures after internal fixation
    • Templeman D, Schmidt A, Freese J, et al. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996;329:194-198.
    • (1996) Clin Orthop Relat Res , vol.329 , pp. 194-198
    • Templeman, D.1    Schmidt, A.2    Freese, J.3
  • 7
    • 0029918309 scopus 로고    scopus 로고
    • Radiologic evaluation of iliosacral screw placement
    • Xu R, Ebraheim NA, Robke J, et al. Radiologic evaluation of iliosacral screw placement. Spine. 1996;21:582-588.
    • (1996) Spine , vol.21 , pp. 582-588
    • Xu, R.1    Ebraheim, N.A.2    Robke, J.3
  • 8
    • 0029689344 scopus 로고    scopus 로고
    • Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
    • Routt ML Jr, Simonian PT, Agnew SG, et al. Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma. 1996;10:171-177.
    • (1996) J Orthop Trauma , vol.10 , pp. 171-177
    • Routt Jr, M.L.1    Simonian, P.T.2    Agnew, S.G.3
  • 9
    • 33646833247 scopus 로고    scopus 로고
    • The effect of sacral fracture malreduction on the safe placement of iliosacral screws
    • Reilly MC, Bono CM, Litkouhi B, et al. The effect of sacral fracture malreduction on the safe placement of iliosacral screws. J Orthop Trauma. 2006;20:S37-43.
    • (2006) J Orthop Trauma , vol.20
    • Reilly, M.C.1    Bono, C.M.2    Litkouhi, B.3
  • 10
    • 0031266643 scopus 로고    scopus 로고
    • Iliosacral screw fixation: Early complications of the percutaneous technique
    • Routt ML Jr, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11:584-589.
    • (1997) J Orthop Trauma , vol.11 , pp. 584-589
    • Routt Jr, M.L.1    Simonian, P.T.2    Mills, W.J.3
  • 11
    • 0033072966 scopus 로고    scopus 로고
    • Early fixation of the vertically unstable pelvis: The role of iliosacral screw fixation of the posterior lesion
    • Keating JF, Werier J, Blachut P, et al. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13:107-113.
    • (1999) J Orthop Trauma , vol.13 , pp. 107-113
    • Keating, J.F.1    Werier, J.2    Blachut, P.3
  • 12
    • 12244267667 scopus 로고    scopus 로고
    • The significance of anode location for stimulus-evoked electromyography during iliosacral screw placement
    • Ricci WM, Padberg AM, Borrelli J. The significance of anode location for stimulus-evoked electromyography during iliosacral screw placement. J Orthop Trauma. 2003;17:95-99.
    • (2003) J Orthop Trauma , vol.17 , pp. 95-99
    • Ricci, W.M.1    Padberg, A.M.2    Borrelli, J.3
  • 13
    • 0031950288 scopus 로고    scopus 로고
    • Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws. An initial clinical study
    • Moed BR, Ahmad BK, Craig JG, et al. Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws. An initial clinical study. J Bone Joint Surg Am. 1998;80:537-546.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 537-546
    • Moed, B.R.1    Ahmad, B.K.2    Craig, J.G.3
  • 14
    • 0034182579 scopus 로고    scopus 로고
    • Electromyography monitoring for percutaneous placement of iliosacral screws
    • Webb LX, de Araujo W, Donofrio P, et al. Electromyography monitoring for percutaneous placement of iliosacral screws. J Orthop Trauma. 2000;14:245-254.
    • (2000) J Orthop Trauma , vol.14 , pp. 245-254
    • Webb, L.X.1    de Araujo, W.2    Donofrio, P.3
  • 15
    • 33645548411 scopus 로고    scopus 로고
    • Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: Comparison between one and two C-arm fluoroscopic techniques
    • Peng KT, Huang KC, Chen MC, et al. Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: comparison between one and two C-arm fluoroscopic techniques. J Trauma. 2006;60:602-608.
    • (2006) J Trauma , vol.60 , pp. 602-608
    • Peng, K.T.1    Huang, K.C.2    Chen, M.C.3
  • 16
    • 33748505196 scopus 로고    scopus 로고
    • Computer-assisted screw placement into the posterior pelvic ring: Assessment of different navigated procedures in a cadaver trial.]
    • Briem D, Rueger JM, Begemann PG, et al. [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial.] Unfallchirurg. 2006;109:640-646.
    • (2006) Unfallchirurg , vol.109 , pp. 640-646
    • Briem, D.1    Rueger, J.M.2    Begemann, P.G.3
  • 17
    • 30944447863 scopus 로고    scopus 로고
    • An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws
    • Smith HE, Yuan PS, Sasso R, et al. An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine. 2006;31:234-238.
    • (2006) Spine , vol.31 , pp. 234-238
    • Smith, H.E.1    Yuan, P.S.2    Sasso, R.3
  • 18
    • 1242320334 scopus 로고    scopus 로고
    • First generation computerized fluoroscopic navigation in percutaneous pelvic surgery
    • Mosheiff R, Khoury A, Weil Y, et al. First generation computerized fluoroscopic navigation in percutaneous pelvic surgery. J Orthop Trauma. 2004;18:106-111.
    • (2004) J Orthop Trauma , vol.18 , pp. 106-111
    • Mosheiff, R.1    Khoury, A.2    Weil, Y.3
  • 19
    • 14844336330 scopus 로고    scopus 로고
    • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy
    • Sagi HC, Lindvall EM. Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trauma. 2005;19:130-133.
    • (2005) J Orthop Trauma , vol.19 , pp. 130-133
    • Sagi, H.C.1    Lindvall, E.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.