메뉴 건너뛰기




Volumn 63, Issue 1, 2007, Pages 97-102

Abdominal ultrasound is an unreliable modality for the detection of hemoperitoneum in patients with pelvic fracture

Author keywords

Abdominal ultrasonography; Hemorrhage; Pelvic fracture

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; HEMOPERITONEUM; HEMORRHAGIC SHOCK; HUMAN; LAPAROTOMY; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD REVIEW; PELVIS ANGIOGRAPHY; PELVIS FRACTURE; PERITONEUM LAVAGE; PREDICTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SYSTOLIC BLOOD PRESSURE; ULTRASOUND;

EID: 34447333157     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e31805f6ffb     Document Type: Article
Times cited : (62)

References (12)
  • 1
    • 0027412284 scopus 로고
    • Abdominal ultrasound as a reliable indicator for conclusive laparotomy in blunt abdominal trauma
    • Bode PJ, Niezen RA, van Vugt AB, Schipper J. Abdominal ultrasound as a reliable indicator for conclusive laparotomy in blunt abdominal trauma. J Trauma. 1993;34:27-31.
    • (1993) J Trauma , vol.34 , pp. 27-31
    • Bode, P.J.1    Niezen, R.A.2    van Vugt, A.B.3    Schipper, J.4
  • 2
    • 0027319470 scopus 로고
    • Prospective evaluation of surgeons' use of ultrasound in the evaluation of trauma patients
    • discussion 526-527
    • Rozycki GS, Ochsner MG, Jaffin JH, Champion HR. Prospective evaluation of surgeons' use of ultrasound in the evaluation of trauma patients. J Trauma. 1993;34:516-526; discussion 526-527.
    • (1993) J Trauma , vol.34 , pp. 516-526
    • Rozycki, G.S.1    Ochsner, M.G.2    Jaffin, J.H.3    Champion, H.R.4
  • 3
    • 0027304189 scopus 로고
    • Prospective comparison of diagnostic peritoneal lavage, computed tomographic scanning, and ultrasonography for the diagnosis of blunt abdominal trauma
    • Liu M, Lee CH, P'eng FK. Prospective comparison of diagnostic peritoneal lavage, computed tomographic scanning, and ultrasonography for the diagnosis of blunt abdominal trauma. J Trauma. 1993;35:267-270.
    • (1993) J Trauma , vol.35 , pp. 267-270
    • Liu, M.1    Lee, C.H.2    P'eng, F.K.3
  • 4
    • 0028041320 scopus 로고
    • Can ultrasound replace diagnostic peritoneal lavage in the assessment of blunt trauma?
    • McKenney M, Lentz K, Nunez D, et al. Can ultrasound replace diagnostic peritoneal lavage in the assessment of blunt trauma? J Trauma. 1994;37:439-441.
    • (1994) J Trauma , vol.37 , pp. 439-441
    • McKenney, M.1    Lentz, K.2    Nunez, D.3
  • 5
    • 0028803754 scopus 로고
    • A prospective study of surgeon-performed ultrasound as the primary adjuvant modality for injured patient assessment
    • discussion 498-500
    • Rozycki GS, Ochsner MG, Schmidt JA, et al. A prospective study of surgeon-performed ultrasound as the primary adjuvant modality for injured patient assessment. J Trauma. 1995;39:492-498; discussion 498-500.
    • (1995) J Trauma , vol.39 , pp. 492-498
    • Rozycki, G.S.1    Ochsner, M.G.2    Schmidt, J.A.3
  • 6
    • 0029924951 scopus 로고    scopus 로고
    • Emergent abdominal sonography as a screening test in a new diagnostic algorithm for blunt trauma
    • Boulanger BR, McLellan BA, Brenneman FD, et al. Emergent abdominal sonography as a screening test in a new diagnostic algorithm for blunt trauma. J Trauma. 1996;40:867-874.
    • (1996) J Trauma , vol.40 , pp. 867-874
    • Boulanger, B.R.1    McLellan, B.A.2    Brenneman, F.D.3
  • 7
    • 0030975344 scopus 로고    scopus 로고
    • Abdominal injuries without hemoperitoneum: A potential limitation of Focused Abdominal Sonography for Trauma (FAST)
    • Chui WC, Cushing BM, Rodriguez A, et al. Abdominal injuries without hemoperitoneum: a potential limitation of Focused Abdominal Sonography for Trauma (FAST). J Trauma. 1997;42:617-625.
    • (1997) J Trauma , vol.42 , pp. 617-625
    • Chui, W.C.1    Cushing, B.M.2    Rodriguez, A.3
  • 8
    • 0032876080 scopus 로고    scopus 로고
    • An algorithm to reduce the incidence of false-negative FAST examinations in patients at high-risk for occult injury
    • Ballard RB, Rozycki GS, Newman PG, et al. An algorithm to reduce the incidence of false-negative FAST examinations in patients at high-risk for occult injury. J Am Coll Surg. 1999;189:145-150.
    • (1999) J Am Coll Surg , vol.189 , pp. 145-150
    • Ballard, R.B.1    Rozycki, G.S.2    Newman, P.G.3
  • 9
    • 0036305776 scopus 로고    scopus 로고
    • The focused abdominal sonography for trauma scan
    • McGahan JP, Richards J, Gillen M. The focused abdominal sonography for trauma scan. J Ultrasound Med. 2002;217:789-800.
    • (2002) J Ultrasound Med , vol.217 , pp. 789-800
    • McGahan, J.P.1    Richards, J.2    Gillen, M.3
  • 10
    • 0032882135 scopus 로고    scopus 로고
    • Prospective evidence of the superiority of a sonography-based algorithm in the assessment of blunt abdominal injury
    • Boulanger BR, McLellan BA, Brenneman FD, Ochoa J, Kirkpatrick AW. Prospective evidence of the superiority of a sonography-based algorithm in the assessment of blunt abdominal injury. J Trauma. 1999;47:632-637.
    • (1999) J Trauma , vol.47 , pp. 632-637
    • Boulanger, B.R.1    McLellan, B.A.2    Brenneman, F.D.3    Ochoa, J.4    Kirkpatrick, A.W.5
  • 11
    • 0033735482 scopus 로고    scopus 로고
    • Focused abdominal US in patients with trauma
    • Lingawi SS, Buckley AR. Focused abdominal US in patients with trauma. Radiology. 2000;217:426-429.
    • (2000) Radiology , vol.217 , pp. 426-429
    • Lingawi, S.S.1    Buckley, A.R.2
  • 12
    • 33646478419 scopus 로고    scopus 로고
    • Prospective study to evaluate the influence of FAST on trauma patient management
    • Ollerton JE, Sugrue M, Balogh Z, D'Amours SK, Giles A, Wyllie P. Prospective study to evaluate the influence of FAST on trauma patient management. J Trauma. 2006;60:785-791.
    • (2006) J Trauma , vol.60 , pp. 785-791
    • Ollerton, J.E.1    Sugrue, M.2    Balogh, Z.3    D'Amours, S.K.4    Giles, A.5    Wyllie, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.