메뉴 건너뛰기




Volumn 10, Issue 2, 2007, Pages 77-84

Pulsatile blood pump with a linear drive actuator

Author keywords

Electromagnetic actuator; Linear drive actuator; Pulsatile pump; Ventricular assist

Indexed keywords

ALGORITHM; ANIMAL EXPERIMENT; ARTICLE; DEVICE; ELECTROMAGNETIC FIELD; GOAT; HEART ASSIST DEVICE; HEART LEFT VENTRICLE; NONHUMAN; OSCILLATOR; PRIORITY JOURNAL; PULSATILE FLOW; THROMBUS;

EID: 34447322824     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-007-0375-2     Document Type: Article
Times cited : (6)

References (15)
  • 9
    • 0037880474 scopus 로고    scopus 로고
    • Newly developed ventricular assist device with linear oscillatory actuator
    • K Fukunaga A Funakubo Y Fukui 2003 Newly developed ventricular assist device with linear oscillatory actuator ASAIO J 49 333 339
    • (2003) ASAIO J , vol.49 , pp. 333-339
    • Fukunaga, K.1    Funakubo, A.2    Fukui, Y.3
  • 10
    • 34447310168 scopus 로고    scopus 로고
    • A new linear oscillatory actuator design for a ventricular-assist device, and thrust analysis thereof
    • K Fukunaga A Funakubo Y Fukui 2002 A new linear oscillatory actuator design for a ventricular-assist device, and thrust analysis thereof Trans Jpn Soc Med Bio Eng 40 201 213
    • (2002) Trans Jpn Soc Med Bio Eng , vol.40 , pp. 201-213
    • Fukunaga, K.1    Funakubo, A.2    Fukui, Y.3
  • 12
    • 0026911757 scopus 로고
    • Development of a single-winding linear oscillatory actuator
    • D Ebihara M Watada 1992 Development of a single-winding linear oscillatory actuator IEEE Trans Mag 28 3030 3032
    • (1992) IEEE Trans Mag , vol.28 , pp. 3030-3032
    • Ebihara, D.1    Watada, M.2
  • 13
    • 0027697714 scopus 로고
    • Improvement on characteristics of linear oscillatory actuator for artificial hearts
    • M Watada Y Yanashima Y Oishi D Ebihara H Dohmeki 1993 Improvement on characteristics of linear oscillatory actuator for artificial hearts IEEE Trans Mag 29 3361 3363
    • (1993) IEEE Trans Mag , vol.29 , pp. 3361-3363
    • Watada, M.1    Yanashima, Y.2    Oishi, Y.3    Ebihara, D.4    Dohmeki, H.5
  • 14
    • 0034533832 scopus 로고    scopus 로고
    • Mechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy
    • S Takatani T Sakamoto 2000 Mechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy J Artif Organs 3 75 84
    • (2000) J Artif Organs , vol.3 , pp. 75-84
    • Takatani, S.1    Sakamoto, T.2
  • 15
    • 0028561834 scopus 로고
    • Development of a compact, highly efficient, totally implantable motor-driven assist pump system
    • 12
    • E Okamoto K Tomoda K Yamamoto Y Mitamura T Mikami 1994 Development of a compact, highly efficient, totally implantable motor-driven assist pump system Artif Organs 18 12 911 917
    • (1994) Artif Organs , vol.18 , pp. 911-917
    • Okamoto, E.1    Tomoda, K.2    Yamamoto, K.3    Mitamura, Y.4    Mikami, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.