메뉴 건너뛰기




Volumn 21, Issue 6, 2007, Pages 394-399

Bioartificial dermal substitute: A preliminary report on its use for the management of complex combat-related soft tissue wounds

Author keywords

Blast injury; Dermal substitute; Integra; Negative pressure dressing; Split thickness skin graft

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL SKIN; BATTLE INJURY; BIOARTIFICIAL ORGAN; BLAST INJURY; BONE; CLINICAL ARTICLE; DEBRIDEMENT; HUMAN; LAVAGE; MALE; MILITARY MEDICINE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SOFT TISSUE INJURY; SPLIT THICKNESS SKIN GRAFT; TENDON; TREATMENT INDICATION; TREATMENT OUTCOME; VACUUM ASSISTED CLOSURE; WOUND DRESSING;

EID: 34447307134     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318070c028     Document Type: Article
Times cited : (95)

References (35)
  • 1
    • 0018841015 scopus 로고
    • Design of an artificial skin. I. Basic design principles
    • Yannas IV, Burke JF. Design of an artificial skin. I. Basic design principles. J Biomed Mater Res. 1980;14:65-81.
    • (1980) J Biomed Mater Res , vol.14 , pp. 65-81
    • Yannas, I.V.1    Burke, J.F.2
  • 2
    • 0018989171 scopus 로고
    • Design of an artificial skin. II. Control of chemical composition
    • Yannas IV, Burke JF, Gordon PL, et al. Design of an artificial skin. II. Control of chemical composition. J Biomed Mater Res. 1980;14:107-131.
    • (1980) J Biomed Mater Res , vol.14 , pp. 107-131
    • Yannas, I.V.1    Burke, J.F.2    Gordon, P.L.3
  • 3
    • 0019449730 scopus 로고
    • Successful use of a physiologically acceptable artificial skin in the treatment of extensive burn injury
    • Burke JF, Yannas IV, Quinby WC, et al. Successful use of a physiologically acceptable artificial skin in the treatment of extensive burn injury. Ann Surg. 1981;194:413-427.
    • (1981) Ann Surg , vol.194 , pp. 413-427
    • Burke, J.F.1    Yannas, I.V.2    Quinby, W.C.3
  • 4
    • 0034950484 scopus 로고    scopus 로고
    • Reconstructive surgery with a dermal regeneration template: Clinical and histologic study
    • Moiemen NS, Staiano JJ, Ojeh NO, et al. Reconstructive surgery with a dermal regeneration template: Clinical and histologic study. Plast Reconstr Surg. 2001;108:93-103.
    • (2001) Plast Reconstr Surg , vol.108 , pp. 93-103
    • Moiemen, N.S.1    Staiano, J.J.2    Ojeh, N.O.3
  • 5
    • 0025229005 scopus 로고
    • Histologic study of artificial skin used in the treatment of full-thickness thermal injury
    • Stern R, McPherson M, Longaker MT. Histologic study of artificial skin used in the treatment of full-thickness thermal injury. J Burn Care Rehabil. 1990;11:7-13.
    • (1990) J Burn Care Rehabil , vol.11 , pp. 7-13
    • Stern, R.1    McPherson, M.2    Longaker, M.T.3
  • 6
    • 0023767336 scopus 로고
    • Artificial dermis for major burns: A multi-center randomized clinical trial
    • Heimbach D, Luterman A, Burke J, et al. Artificial dermis for major burns: A multi-center randomized clinical trial. Ann Surg. 1988;208:313-319.
    • (1988) Ann Surg , vol.208 , pp. 313-319
    • Heimbach, D.1    Luterman, A.2    Burke, J.3
  • 7
    • 0345328647 scopus 로고    scopus 로고
    • Dermal regeneration template for deep hand burns: Clinical utility for both early grafting and reconstructive surgery
    • Dantzer E, Queruel P, Salinier L, et al. Dermal regeneration template for deep hand burns: clinical utility for both early grafting and reconstructive surgery. Br J Plast Surg. 2003;56:764-774.
    • (2003) Br J Plast Surg , vol.56 , pp. 764-774
    • Dantzer, E.1    Queruel, P.2    Salinier, L.3
  • 8
    • 2342637697 scopus 로고    scopus 로고
    • Use of dermal regeneration template in contracture release procedures: A multicenter evaluation
    • Frame JD, Still J, Lakhel-LeCoadou A, et al. Use of dermal regeneration template in contracture release procedures: A multicenter evaluation. Plast Reconstr Surg. 2004;113:1330-1338.
    • (2004) Plast Reconstr Surg , vol.113 , pp. 1330-1338
    • Frame, J.D.1    Still, J.2    Lakhel-LeCoadou, A.3
  • 10
    • 0032763613 scopus 로고    scopus 로고
    • The use of collagen-GAG membranes in reconstructive surgery
    • Orgill DP, Straus FH, Lee RC. The use of collagen-GAG membranes in reconstructive surgery. Ann N Y Acad Sci. 1999;888:233-248.
    • (1999) Ann N Y Acad Sci , vol.888 , pp. 233-248
    • Orgill, D.P.1    Straus, F.H.2    Lee, R.C.3
  • 11
    • 4744368037 scopus 로고    scopus 로고
    • Paediatric upper limb contracture release following burn injury
    • Young RC, Burd A. Paediatric upper limb contracture release following burn injury. Burns. 2004;30:723-728.
    • (2004) Burns , vol.30 , pp. 723-728
    • Young, R.C.1    Burd, A.2
  • 12
    • 0035071644 scopus 로고    scopus 로고
    • The use of a bilaminate artificial skin substitute (Integra) in acute resurfacing of burns: An early experience
    • Fitton AR, Drew P, Dickson WA. The use of a bilaminate artificial skin substitute (Integra) in acute resurfacing of burns: an early experience. Br J Plast Surg. 2001;54:208-212.
    • (2001) Br J Plast Surg , vol.54 , pp. 208-212
    • Fitton, A.R.1    Drew, P.2    Dickson, W.A.3
  • 13
    • 0037254833 scopus 로고    scopus 로고
    • Multicenter postapproval clinical trial of Integra dermal regeneration template for burn treatment
    • Heimbach DM, Warden GD, Luterman A, et al. Multicenter postapproval clinical trial of Integra dermal regeneration template for burn treatment. J Burn Care Rehabil. 2003;24:42-48.
    • (2003) J Burn Care Rehabil , vol.24 , pp. 42-48
    • Heimbach, D.M.1    Warden, G.D.2    Luterman, A.3
  • 14
    • 3042685018 scopus 로고    scopus 로고
    • Update on the use of collagen/ glycosaminoglycate skin substitute - six years of experiences with artificial skin in 15 German burn centers
    • Heitland A, Piatkowski A, Noah EM, et al. Update on the use of collagen/ glycosaminoglycate skin substitute - six years of experiences with artificial skin in 15 German burn centers. Burns. 2004;30:471-475.
    • (2004) Burns , vol.30 , pp. 471-475
    • Heitland, A.1    Piatkowski, A.2    Noah, E.M.3
  • 15
    • 0035208941 scopus 로고    scopus 로고
    • Reconstructive surgery using an artificial dermis (Integra): Results with 39 grafts
    • Dantzer E, Braye FM. Reconstructive surgery using an artificial dermis (Integra): Results with 39 grafts. Br J Plast Surg. 2001;54:659-664.
    • (2001) Br J Plast Surg , vol.54 , pp. 659-664
    • Dantzer, E.1    Braye, F.M.2
  • 16
    • 30144437492 scopus 로고    scopus 로고
    • Successful management and surgical closure of chronic and pathological wounds using Integra
    • Gottlieb ME, Furman J. Successful management and surgical closure of chronic and pathological wounds using Integra. J Burns Surg Wound Care. 2004;3:4.
    • (2004) J Burns Surg Wound Care , vol.3 , pp. 4
    • Gottlieb, M.E.1    Furman, J.2
  • 17
    • 0032853350 scopus 로고    scopus 로고
    • Application of artificial dermis prior to full thickness grafting for resurfacing the nose
    • Suzuki S, Shin-ya K, Kawai K, et al. Application of artificial dermis prior to full thickness grafting for resurfacing the nose. Ann Plast Surg. 1999;43:439-442.
    • (1999) Ann Plast Surg , vol.43 , pp. 439-442
    • Suzuki, S.1    Shin-ya, K.2    Kawai, K.3
  • 18
    • 0033967637 scopus 로고    scopus 로고
    • Application of dermal substitute (Integra) to donor site defect of forehead flap
    • Wang JCY, To EWH. Application of dermal substitute (Integra) to donor site defect of forehead flap. Br J Plast Surg. 2000;53:70-72.
    • (2000) Br J Plast Surg , vol.53 , pp. 70-72
    • Wang, J.C.Y.1    To, E.W.H.2
  • 19
    • 32944475684 scopus 로고    scopus 로고
    • The use of dermal template INTEGRA in a scalpation injury of hand
    • Bansky R. The use of dermal template INTEGRA in a scalpation injury of hand. Bratisl Lek Listy. 2005;106:221-225.
    • (2005) Bratisl Lek Listy , vol.106 , pp. 221-225
    • Bansky, R.1
  • 20
    • 0042834259 scopus 로고    scopus 로고
    • Experience with bilaminate bioartificial skin substitute and ultrathin skin grafting in non-burn soft-tissue wound defects
    • Demarest GB, Resurrecion R, Lu S, et al. Experience with bilaminate bioartificial skin substitute and ultrathin skin grafting in non-burn soft-tissue wound defects. Wounds. 2003;15:250-256.
    • (2003) Wounds , vol.15 , pp. 250-256
    • Demarest, G.B.1    Resurrecion, R.2    Lu, S.3
  • 21
    • 24744437951 scopus 로고    scopus 로고
    • Integra artificial skin in the management of severe tissue defects, including bone exposure, in injured children
    • Violas P, Abid A, Darodes P, et al. Integra artificial skin in the management of severe tissue defects, including bone exposure, in injured children. J Pediatr Orthop B. 2005;14:381-384.
    • (2005) J Pediatr Orthop B , vol.14 , pp. 381-384
    • Violas, P.1    Abid, A.2    Darodes, P.3
  • 22
    • 14944362299 scopus 로고    scopus 로고
    • The use of Integra in an upper extremity avulsion injury
    • Wolter TP, Noah EM, Pallua N. The use of Integra in an upper extremity avulsion injury. Br J Plast Surg. 2005;58:416-418.
    • (2005) Br J Plast Surg , vol.58 , pp. 416-418
    • Wolter, T.P.1    Noah, E.M.2    Pallua, N.3
  • 23
    • 13444265162 scopus 로고    scopus 로고
    • Informed consent should be obtained from patients to use products (skin substitutes) and dressings containing biological material
    • Enoch S, Shaaban H, Dunn KW. Informed consent should be obtained from patients to use products (skin substitutes) and dressings containing biological material. J Med Ethics. 2005;31:2-6.
    • (2005) J Med Ethics , vol.31 , pp. 2-6
    • Enoch, S.1    Shaaban, H.2    Dunn, K.W.3
  • 24
    • 1442264094 scopus 로고    scopus 로고
    • Development of new reconstructive techniques: Use of Integra in combination with fibrin glue and negative-pressure therapy for reconstruction of acute and chronic wounds
    • Jeschke MG, Rose C, Angele P, et al. Development of new reconstructive techniques: use of Integra in combination with fibrin glue and negative-pressure therapy for reconstruction of acute and chronic wounds. Plast Reconstr Surg. 2004;113:525-530.
    • (2004) Plast Reconstr Surg , vol.113 , pp. 525-530
    • Jeschke, M.G.1    Rose, C.2    Angele, P.3
  • 25
    • 1842735221 scopus 로고    scopus 로고
    • Suction dressings to secure a dermal substitute
    • McEwan W, Brown TH, Mills SM, et al. Suction dressings to secure a dermal substitute. Burns. 2004;30:259-261.
    • (2004) Burns , vol.30 , pp. 259-261
    • McEwan, W.1    Brown, T.H.2    Mills, S.M.3
  • 26
    • 2342540396 scopus 로고    scopus 로고
    • Acceleration of Integra incorporation in complex tissue defects with subatmospheric pressure
    • Molnar JA, DeFranzo AJ, Hadaegh A, et al. Acceleration of Integra incorporation in complex tissue defects with subatmospheric pressure. Plast Recon Surg. 2004;113:1339-1346.
    • (2004) Plast Recon Surg , vol.113 , pp. 1339-1346
    • Molnar, J.A.1    DeFranzo, A.J.2    Hadaegh, A.3
  • 27
    • 0036719730 scopus 로고    scopus 로고
    • Dermatome setting for autografts to cover INTEGRA
    • Fang P, Engrav LH, Gibran NS, et al. Dermatome setting for autografts to cover INTEGRA. J Burn Care Rehabil. 2002;23:327-332.
    • (2002) J Burn Care Rehabil , vol.23 , pp. 327-332
    • Fang, P.1    Engrav, L.H.2    Gibran, N.S.3
  • 28
    • 0030940249 scopus 로고    scopus 로고
    • Vacuum-assisted closure: A new method for wound control and treatment: clinical Experience
    • Argenta LC, Morykwas MJ. Vacuum-assisted closure: a new method for wound control and treatment: clinical Experience. Ann Plast Surg. 1997;38:563-576.
    • (1997) Ann Plast Surg , vol.38 , pp. 563-576
    • Argenta, L.C.1    Morykwas, M.J.2
  • 29
    • 0031950262 scopus 로고    scopus 로고
    • Negative-pressure dressings as a bolster for skin grafts
    • Blackburn JH, Boemi L, Hall WW, et al. Negative-pressure dressings as a bolster for skin grafts. Ann Plast Surg. 1998;40:453-457.
    • (1998) Ann Plast Surg , vol.40 , pp. 453-457
    • Blackburn, J.H.1    Boemi, L.2    Hall, W.W.3
  • 30
    • 0034796778 scopus 로고    scopus 로고
    • The use of vacuum-assisted closure therapy for the treatment of lower extremity wounds with exposed bone
    • DeFranzo AJ, Argenta LC, Marks MW, et al. The use of vacuum-assisted closure therapy for the treatment of lower extremity wounds with exposed bone. Plast Reconstr Surg. 2001;108:1184-1191.
    • (2001) Plast Reconstr Surg , vol.108 , pp. 1184-1191
    • DeFranzo, A.J.1    Argenta, L.C.2    Marks, M.W.3
  • 31
    • 0036324167 scopus 로고    scopus 로고
    • The vacuum assisted closure device: A method of securing skin grafts and improving graft survival
    • Scherer LA, Shiver S, Chang M, et al. The vacuum assisted closure device: a method of securing skin grafts and improving graft survival. Arch Surg. 2002;137:930-934.
    • (2002) Arch Surg , vol.137 , pp. 930-934
    • Scherer, L.A.1    Shiver, S.2    Chang, M.3
  • 32
    • 0031696351 scopus 로고    scopus 로고
    • A new and reliable method of securing skin grafts to the difficult recipient bed
    • Schneider AM, Morykwas MJ, Argenta LC. A new and reliable method of securing skin grafts to the difficult recipient bed. Plast Reconstr Surg. 1998;102:1195-1198.
    • (1998) Plast Reconstr Surg , vol.102 , pp. 1195-1198
    • Schneider, A.M.1    Morykwas, M.J.2    Argenta, L.C.3
  • 33
    • 0036727436 scopus 로고    scopus 로고
    • New techniques in wound management: Vacuum-assisted wound closure
    • Webb LX. New techniques in wound management: vacuum-assisted wound closure. J Am Acad Orthop Surg. 2002;10:303-311.
    • (2002) J Am Acad Orthop Surg , vol.10 , pp. 303-311
    • Webb, L.X.1
  • 34
    • 0345798155 scopus 로고    scopus 로고
    • A prospective study of microvascular free-flap surgery and outcome
    • Khouri RK, Cooley BC, Kunselman A, et al. A prospective study of microvascular free-flap surgery and outcome. Plast Reconstr Surg. 1998;102:711-721.
    • (1998) Plast Reconstr Surg , vol.102 , pp. 711-721
    • Khouri, R.K.1    Cooley, B.C.2    Kunselman, A.3
  • 35
    • 0035110247 scopus 로고    scopus 로고
    • Functional donor-site morbidity during level and uphill gait after a gastrocnemius or soleus muscle-flap procedure
    • Kramers-de Quervain IA, Luuffer JM, et al. Functional donor-site morbidity during level and uphill gait after a gastrocnemius or soleus muscle-flap procedure. J Bone Joint Surg Am. 2001;83:239-246.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 239-246
    • Kramers-de Quervain, I.A.1    Luuffer, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.