Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?

Author keywords

Computed tomography (CT); Image distortion; Knee; Magnetic resonance imaging (MRI); Three dimensional kinematics

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EXPERIMENTAL MODEL; FEMUR; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; KINEMATICS; KNEE; KNEE FUNCTION; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUALITY CONTROL; QUANTITATIVE ANALYSIS; THREE DIMENSIONAL IMAGING; TIBIA;

EID: 34447290494     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.20355     Document Type: Article
Times cited : (123)

References (20)
  • 1
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks SA, Hodge WA. 1996. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43: 638-649.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 2
    • 0038066801 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of the normal human knee
    • Komistek RD, Dennis DA, Mahfouz M. 2003. In vivo fluoroscopic analysis of the normal human knee. Clin Orthop 69-81.
    • (2003) Clin Orthop , pp. 69-81
    • Komistek, R.D.1    Dennis, D.A.2    Mahfouz, M.3
  • 3
    • 2542471541 scopus 로고    scopus 로고
    • Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy
    • Yamazaki T, Watanabe T, Nakajima Y, et al. 2004. Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Med Imaging 23:602-612.
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 602-612
    • Yamazaki, T.1    Watanabe, T.2    Nakajima, Y.3
  • 4
    • 4344608316 scopus 로고    scopus 로고
    • In vivo tibiofemoral contact analysis using 3D MRI-based knee models
    • DeFrate LE, Sun H, Gill TJ, et al. 2004. In vivo tibiofemoral contact analysis using 3D MRI-based knee models. J Biomech 37:1499-1504.
    • (2004) J Biomech , vol.37 , pp. 1499-1504
    • DeFrate, L.E.1    Sun, H.2    Gill, T.J.3
  • 5
    • 0034962837 scopus 로고    scopus 로고
    • In vivo three-dimensional knee kinematics using a biplanar image-matching technique
    • Asano T, Akagi M, Tanaka K, et al. 2001. In vivo three-dimensional knee kinematics using a biplanar image-matching technique. Clin Orthop 157-166.
    • (2001) Clin Orthop , pp. 157-166
    • Asano, T.1    Akagi, M.2    Tanaka, K.3
  • 6
    • 23644455465 scopus 로고    scopus 로고
    • Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy
    • Fregly BJ, Rahman HA, Banks SA. 2005. Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy. J Biomech Eng 127:692-699.
    • (2005) J Biomech Eng , vol.127 , pp. 692-699
    • Fregly, B.J.1    Rahman, H.A.2    Banks, S.A.3
  • 7
    • 0035354206 scopus 로고    scopus 로고
    • In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: Application to knee kinematics
    • You BM, Siy P, Anderst W, et al. 2001. In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: application to knee kinematics. IEEE Trans Med Imaging 20:514-525.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 514-525
    • You, B.M.1    Siy, P.2    Anderst, W.3
  • 8
    • 2442584529 scopus 로고    scopus 로고
    • Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics
    • Li G, Wuerz TH, DeFrate LE. 2004. Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. J Biomech Eng 126:314-318.
    • (2004) J Biomech Eng , vol.126 , pp. 314-318
    • Li, G.1    Wuerz, T.H.2    DeFrate, L.E.3
  • 9
    • 17144430524 scopus 로고    scopus 로고
    • A complete distortion correction for MR images: I. Gradient warp correction
    • Doran SJ, Charles-Edwards L, Reinsberg SA, et al. 2005. A complete distortion correction for MR images: I. Gradient warp correction. Phys Med Biol 50:1343-1361.
    • (2005) Phys Med Biol , vol.50 , pp. 1343-1361
    • Doran, S.J.1    Charles-Edwards, L.2    Reinsberg, S.A.3
  • 11
    • 0031969773 scopus 로고    scopus 로고
    • Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm
    • Hill DL, Maurer CR Jr, Studholme C, et al. 1998. Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm. J Comput Assist Tomogr 22:317-323.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 317-323
    • Hill, D.L.1    Maurer Jr, C.R.2    Studholme, C.3
  • 13
    • 0032992683 scopus 로고    scopus 로고
    • MRI geometric distortion: A simple approach to correcting the effects of non-linear gradient fields
    • Langlois S, Desvignes M, Constans JM, et al. 1999. MRI geometric distortion: a simple approach to correcting the effects of non-linear gradient fields. J Magn Reson Imaging 9:821-831.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 821-831
    • Langlois, S.1    Desvignes, M.2    Constans, J.M.3
  • 14
    • 8944225505 scopus 로고    scopus 로고
    • Effect of geometrical distortion correction in MR on image registration accuracy
    • Maurer CR Jr, Aboutanos GB, Dawant BM, et al. 1996. Effect of geometrical distortion correction in MR on image registration accuracy. J Comput Assist Tomogr 20:666-679.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 666-679
    • Maurer Jr, C.R.1    Aboutanos, G.B.2    Dawant, B.M.3
  • 15
    • 85024996935 scopus 로고    scopus 로고
    • Quality assurance of registration of CT and MRI data sets for treatment planning of radiotherapy for head and neck cancers
    • Moore CS, Liney GP, Beavis AW. 2004. Quality assurance of registration of CT and MRI data sets for treatment planning of radiotherapy for head and neck cancers. J Appl Clin Med Phys 5:25-35.
    • (2004) J Appl Clin Med Phys , vol.5 , pp. 25-35
    • Moore, C.S.1    Liney, G.P.2    Beavis, A.W.3
  • 16
    • 0028089390 scopus 로고
    • Quantifying MRI geometric distortion in tissue
    • Sumanaweera T, Glover G, Song S, et al. 1994. Quantifying MRI geometric distortion in tissue. Magn Reson Med 31:40-47.
    • (1994) Magn Reson Med , vol.31 , pp. 40-47
    • Sumanaweera, T.1    Glover, G.2    Song, S.3
  • 19
    • 28544442112 scopus 로고    scopus 로고
    • Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality
    • Eckhoff DG, Bach JM, Spitzer VM, et al. 2005. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg [Am] 87: (Suppl 2):71-80.
    • (2005) J Bone Joint Surg [Am] , vol.87 , Issue.SUPPL. 2 , pp. 71-80
    • Eckhoff, D.G.1    Bach, J.M.2    Spitzer, V.M.3
  • 20
    • 14244259567 scopus 로고    scopus 로고
    • A new tibial coordinate system improves the precision of anterior-posterior knee laxity measurements: A cadaveric study using Roentgen stereophotogrammetric analysis
    • Roos PJ, Neu CP, Hull ML, et al. 2005. A new tibial coordinate system improves the precision of anterior-posterior knee laxity measurements: a cadaveric study using Roentgen stereophotogrammetric analysis. J Orthop Res 23:327-333.
    • (2005) J Orthop Res , vol.23 , pp. 327-333
    • Roos, P.J.1    Neu, C.P.2    Hull, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.