메뉴 건너뛰기




Volumn 14, Issue 4, 2007, Pages 280-283

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: A study in 10 cadaver femora

Author keywords

Alignment; Extramedullary rod; Femoral component; Intramedullary rod; Unicompartmental knee

Indexed keywords

ACCURACY; ARTICLE; CADAVER; FEMUR; HUMAN; INTRAMEDULLARY NAILING; KNEE ARTHROPLASTY; MEASUREMENT ERROR; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 34447267240     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2007.04.007     Document Type: Article
Times cited : (17)

References (7)
  • 1
    • 0031791833 scopus 로고    scopus 로고
    • The Oxford medial unicompartmental arthroplasty: a ten-year survival study
    • Murray D.W., Goodfellow J.W., and O'Connor J.J. The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg Br 80 (1998) 983-989
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 983-989
    • Murray, D.W.1    Goodfellow, J.W.2    O'Connor, J.J.3
  • 3
    • 27744528422 scopus 로고    scopus 로고
    • Accuracy of implantation of components in the Oxford knee using the minimally invasive approach
    • Shakespeare D., Ledger M., and Kinzel V. Accuracy of implantation of components in the Oxford knee using the minimally invasive approach. Knee 12 (2005) 405-409
    • (2005) Knee , vol.12 , pp. 405-409
    • Shakespeare, D.1    Ledger, M.2    Kinzel, V.3
  • 4
    • 0035215472 scopus 로고    scopus 로고
    • Rapid recovery after oxford unicompartmental arthroplasty through a short incision
    • Price A.J., Webb J., Topf H., Dodd C.A., Goodfellow J.W., and Murray D.W. Rapid recovery after oxford unicompartmental arthroplasty through a short incision. J Arthroplasty 16 (2001) 970-976
    • (2001) J Arthroplasty , vol.16 , pp. 970-976
    • Price, A.J.1    Webb, J.2    Topf, H.3    Dodd, C.A.4    Goodfellow, J.W.5    Murray, D.W.6
  • 5
    • 33644770214 scopus 로고    scopus 로고
    • Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty
    • Ma B., Long W., Rudan J.F., and Ellis R.E. Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. J Arthroplasty 21 (2006) 271-278
    • (2006) J Arthroplasty , vol.21 , pp. 271-278
    • Ma, B.1    Long, W.2    Rudan, J.F.3    Ellis, R.E.4
  • 6
    • 0031734854 scopus 로고    scopus 로고
    • Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens
    • Psychoyios V., Crawford R.W., O'Connor J.J., and Murray D.W. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens. J Bone Joint Surg Br 80 (1998) 976-982
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 976-982
    • Psychoyios, V.1    Crawford, R.W.2    O'Connor, J.J.3    Murray, D.W.4
  • 7
    • 0034892245 scopus 로고    scopus 로고
    • Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty
    • Novotny J., Gonzalez M.H., Amirouche F.M., and Y.C.L. Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 16 (2001) 641-647
    • (2001) J Arthroplasty , vol.16 , pp. 641-647
    • Novotny, J.1    Gonzalez, M.H.2    Amirouche, F.M.3    Li, Y.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.