-
1
-
-
33846844316
-
On-line separation and preconcentration in flow injection analysis
-
Fang Z, Zhu Z, Zhang S, Xu S, Guo L, Sun L. On-line separation and preconcentration in flow injection analysis. Anal. Chim. Acta 1988;214:41-55.
-
(1988)
Anal. Chim. Acta
, vol.214
, pp. 41-55
-
-
Fang, Z.1
Zhu, Z.2
Zhang, S.3
Xu, S.4
Guo, L.5
Sun, L.6
-
2
-
-
0038784768
-
-
Camel V. Spectrochim. Acta B. Solid phase extraction of trace elements 2003;58:1177-1233.
-
Camel V. Spectrochim. Acta B. Solid phase extraction of trace elements 2003;58:1177-1233.
-
-
-
-
3
-
-
0029159004
-
Determination of cadmium and lead in vegetables after activated-carbon enrichment by atomic absorption spectrometry
-
Yaman M, Gucer S. Determination of cadmium and lead in vegetables after activated-carbon enrichment by atomic absorption spectrometry. Analyst 1995;120:101-105.
-
(1995)
Analyst
, vol.120
, pp. 101-105
-
-
Yaman, M.1
Gucer, S.2
-
4
-
-
0032999445
-
Study of the adsorption of Cd and Zn onto an activated-carbon: Influence of pH, cation concentration, and adsorbent concentration
-
Seco A, Marzal P, Gabaldon C. Study of the adsorption of Cd and Zn onto an activated-carbon: Influence of pH, cation concentration, and adsorbent concentration. Sep. Sci. Technol. 1999;34:1577-1593.
-
(1999)
Sep. Sci. Technol
, vol.34
, pp. 1577-1593
-
-
Seco, A.1
Marzal, P.2
Gabaldon, C.3
-
5
-
-
33644519305
-
Fixed bed column study for Cd(II) removal from wastewater using treated rice husk
-
Kumar U, Bandyopadhyay M. Fixed bed column study for Cd(II) removal from wastewater using treated rice husk. J. Hazard. Mater. 2006;129:253-259.
-
(2006)
J. Hazard. Mater
, vol.129
, pp. 253-259
-
-
Kumar, U.1
Bandyopadhyay, M.2
-
6
-
-
0033549538
-
Determination of Cu(II) and Zn(II) using silica gel loaded with 1-(2-thiasolylazo)-2-naphthol
-
Zaporozhets OA, Petruniock N, Bessarabova O, Sukhan V. Determination of Cu(II) and Zn(II) using silica gel loaded with 1-(2-thiasolylazo)-2-naphthol. Talanta 1999;49:899-906.
-
(1999)
Talanta
, vol.49
, pp. 899-906
-
-
Zaporozhets, O.A.1
Petruniock, N.2
Bessarabova, O.3
Sukhan, V.4
-
7
-
-
0030474061
-
Solid-phase extraction of metal ions and their estimation in vitamins, steel and milk using 3-hydroxy-2-methyl- 1,4-naphthoquinone-immobilized silica gel
-
Garg BS, Bist JS, Sharma RK, Bhojak N. Solid-phase extraction of metal ions and their estimation in vitamins, steel and milk using 3-hydroxy-2-methyl- 1,4-naphthoquinone-immobilized silica gel. Talanta 1996;43:2093-2099.
-
(1996)
Talanta
, vol.43
, pp. 2093-2099
-
-
Garg, B.S.1
Bist, J.S.2
Sharma, R.K.3
Bhojak, N.4
-
8
-
-
0031944743
-
Application of 2-mercaptobenzothiazole-modified silica gel to on-line preconcentration and separation of silver for its atomic absorption spectrometric determination
-
Pu Q, Sun Q. Application of 2-mercaptobenzothiazole-modified silica gel to on-line preconcentration and separation of silver for its atomic absorption spectrometric determination. Analyst 1998;123:239-244.
-
(1998)
Analyst
, vol.123
, pp. 239-244
-
-
Pu, Q.1
Sun, Q.2
-
9
-
-
0035053699
-
Determination of trace elements by inductively coupled plasma - atomic emission spectrometry (ICP - AES) after preconcentration on a support impregnated with piperdine dithiocarbamate
-
Ramesh A, Rama Mohan K, Jeya Kumar ND, Seshaiah K. Determination of trace elements by inductively coupled plasma - atomic emission spectrometry (ICP - AES) after preconcentration on a support impregnated with piperdine dithiocarbamate. Anal. Lett. 2001;34:219-229.
-
(2001)
Anal. Lett
, vol.34
, pp. 219-229
-
-
Ramesh, A.1
Rama Mohan, K.2
Jeya Kumar, N.D.3
Seshaiah, K.4
-
10
-
-
0029050448
-
Column solid phase extraction as preconcentration method for trace element determination in oxalic acid by atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry
-
Alexandrova A, Arpadjan S. Column solid phase extraction as preconcentration method for trace element determination in oxalic acid by atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry. Anal. Chim. Acta 1995;307:71-77.
-
(1995)
Anal. Chim. Acta
, vol.307
, pp. 71-77
-
-
Alexandrova, A.1
Arpadjan, S.2
-
11
-
-
0030892764
-
Sorption of arsenic, aismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry
-
Arpadjan S, Vuchkova L, Kostadinova E. Sorption of arsenic, aismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry. Analyst 1997;122:243-246.
-
(1997)
Analyst
, vol.122
, pp. 243-246
-
-
Arpadjan, S.1
Vuchkova, L.2
Kostadinova, E.3
-
12
-
-
0033006328
-
Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN
-
Ferreira SLC, De Brito CF, Dantas AF, De Araujo NML, Costa ACS. Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN. Talanta 1999;48:1173-1177.
-
(1999)
Talanta
, vol.48
, pp. 1173-1177
-
-
Ferreira, S.L.C.1
De Brito, C.F.2
Dantas, A.F.3
De Araujo, N.M.L.4
Costa, A.C.S.5
-
13
-
-
0028142141
-
Synthesis of a chelating polymer matrix by immobilizing Alizarin Red-S on Amberlite XAD-2 and its application to the preconcentration of lead(II), cadmium(II), zinc(II) and nickel(II)
-
Saxena R, Singh AK, Sambi SS. Synthesis of a chelating polymer matrix by immobilizing Alizarin Red-S on Amberlite XAD-2 and its application to the preconcentration of lead(II), cadmium(II), zinc(II) and nickel(II). Anal. Chim. Acta 1994;295:199-204.
-
(1994)
Anal. Chim. Acta
, vol.295
, pp. 199-204
-
-
Saxena, R.1
Singh, A.K.2
Sambi, S.S.3
-
14
-
-
0034950497
-
Field sample preconcentration of copper in sea water using chelating minicolumns subsequently incorporated on a flow-injection-flame atomic absorption spectrometry system
-
Yebra MC, Carro N, Enriquez MF, Moreno C, Garcia A. Field sample preconcentration of copper in sea water using chelating minicolumns subsequently incorporated on a flow-injection-flame atomic absorption spectrometry system. Analyst 2001;126:933-937.
-
(2001)
Analyst
, vol.126
, pp. 933-937
-
-
Yebra, M.C.1
Carro, N.2
Enriquez, M.F.3
Moreno, C.4
Garcia, A.5
-
16
-
-
2142695715
-
Sulphoxine immobilized onto chitosan microspheres by spray drying: Application for metal ions preconcentration by flow injection analysis
-
Martins AO, Da Silva EL, Carasek E, Laranjeira MCM, De Fa'vere VT. Sulphoxine immobilized onto chitosan microspheres by spray drying: Application for metal ions preconcentration by flow injection analysis. Talanta 2004;63:397-403.
-
(2004)
Talanta
, vol.63
, pp. 397-403
-
-
Martins, A.O.1
Da Silva, E.L.2
Carasek, E.3
Laranjeira, M.C.M.4
De Fa'vere, V.T.5
-
17
-
-
8444248219
-
Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with O,O-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4
-
Santos EJD, Hermann AB, Ribeiro AS, Curtius AJ. Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with O,O-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4. Talanta 2005;65:593-597.
-
(2005)
Talanta
, vol.65
, pp. 593-597
-
-
Santos, E.J.D.1
Hermann, A.B.2
Ribeiro, A.S.3
Curtius, A.J.4
-
18
-
-
0012264013
-
Pyrogallol immobilized Amberlite XAD-2: A newly designed collector for enrichment of metal ions prior to their determination by flame atomic absorption spectrometry
-
Kumar M, Rathore DPS, Singh AK. Pyrogallol immobilized Amberlite XAD-2: A newly designed collector for enrichment of metal ions prior to their determination by flame atomic absorption spectrometry. Michrochim. Acta 2001;137:127-134.
-
(2001)
Michrochim. Acta
, vol.137
, pp. 127-134
-
-
Kumar, M.1
Rathore, D.P.S.2
Singh, A.K.3
-
19
-
-
0034232335
-
Amberlite XAD-7 impregnated with Xylenol Orange: A chelating collector for preconcentration of Cd(II), Co(II), Cu(II), Ni(II), Zn(II) and Fe(III) ions prior to their determination by flame AAS
-
Tewari PK, Singh AK. Amberlite XAD-7 impregnated with Xylenol Orange: A chelating collector for preconcentration of Cd(II), Co(II), Cu(II), Ni(II), Zn(II) and Fe(III) ions prior to their determination by flame AAS. Fresenius. J. Anal. Chem. 2000;367:562-567.
-
(2000)
Fresenius. J. Anal. Chem
, vol.367
, pp. 562-567
-
-
Tewari, P.K.1
Singh, A.K.2
-
20
-
-
0037118092
-
Preconcentration of trace metals on Amberlite XAD-4 resin coated with dithiocarbamates and determination by inductively coupled plasma-atomic emission spectrometry in saline matrices
-
Ramesh A, Mohan KR, Seshaiah K. Preconcentration of trace metals on Amberlite XAD-4 resin coated with dithiocarbamates and determination by inductively coupled plasma-atomic emission spectrometry in saline matrices. Talanta 2002;57:243-252.
-
(2002)
Talanta
, vol.57
, pp. 243-252
-
-
Ramesh, A.1
Mohan, K.R.2
Seshaiah, K.3
-
21
-
-
23444439335
-
Multi-element pre-concentration of heavy metal ions by solid phase extraction on Chromosorb 108
-
Tuzen M, Soylak M, Elci L. Multi-element pre-concentration of heavy metal ions by solid phase extraction on Chromosorb 108. Anal. Chim. Acta 2005;548:101-108.
-
(2005)
Anal. Chim. Acta
, vol.548
, pp. 101-108
-
-
Tuzen, M.1
Soylak, M.2
Elci, L.3
|