Silent cerebral infarct after cardiac catheterization as detected by diffusion weighted Magnetic Resonance Imaging: A randomized comparison of radial and femoral arterial approaches

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOCARDIOGRAPHY; AORTA VALVE STENOSIS; ARTICLE; AUSTRIA; BRAIN BLOOD FLOW; BRAIN EMBOLISM; BRAIN INFARCTION; CLINICAL TRIAL; COGNITIVE DEFECT; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIFFUSION WEIGHTED IMAGING; DISEASE SEVERITY; DOPPLER ECHOGRAPHY; FEMORAL ARTERY; FRANCE; HEART CATHETERIZATION; HUMAN; INTERMETHOD COMPARISON; ITALY; MULTICENTER STUDY; NEUROLOGIC EXAMINATION; NEUROPSYCHOLOGICAL TEST; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PATIENT MONITORING; RADIAL ARTERY; RANDOMIZED CONTROLLED TRIAL; SAMPLE SIZE; TIME; VASCULAR ACCESS;

EID: 34347406532     PISSN: 17456215     EISSN: 17456215     Source Type: Journal    
DOI: 10.1186/1745-6215-8-15     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 0035836623 scopus 로고    scopus 로고
    • Stroke as a complication of cardiac catheterization: Risk factors and clinical features
    • 11294941
    • Segal AZ Abernethy WB Placios IF BeLue R Rordorf G Stroke as a complication of cardiac catheterization: Risk factors and clinical features Neurology 2001 56 975-977 11294941
    • (2001) Neurology , vol.56 , pp. 975-977
    • Segal, A.Z.1    Abernethy, W.B.2    Placios, I.F.3    BeLue, R.4    Rordorf, G.5
  • 2
    • 27144448747 scopus 로고    scopus 로고
    • Neurological complications following percutaneous coronary interventions (A report from the 2000-2001 new York state angioplasty registry)
    • 10.1016/j.amjcard.2005.06.065 16253591
    • Wong SC Minutello R Hong MK Neurological complications following percutaneous coronary interventions (A report from the 2000-2001 new York state angioplasty registry) Am J Cardiol 2005 96 1248-1250 10.1016/ j.amjcard.2005.06.065 16253591
    • (2005) Am J Cardiol , vol.96 , pp. 1248-1250
    • Wong, S.C.1    Minutello, R.2    Hong, M.K.3
  • 4
    • 15944394415 scopus 로고    scopus 로고
    • Cerebral infarction incidence and risk factors after diagnostic and interventional cardiac catheterization-prospective evaluation at diffusion-weighted MR imaging
    • 10.1148/radiol.2351040117 15731373
    • Busing KA Schulte-Sasse C Flucher S Suelbeck T Haase KK Neff W Hirsch JG Borggrefe M Duber C Cerebral infarction incidence and risk factors after diagnostic and interventional cardiac catheterization-prospective evaluation at diffusion-weighted MR imaging Radiology 2005 235 177-183 10.1148/radiol.2351040117 15731373
    • (2005) Radiology , vol.235 , pp. 177-183
    • Busing, K.A.1    Schulte-Sasse, C.2    Flucher, S.3    Suelbeck, T.4    Haase, K.K.5    Neff, W.6    Hirsch, J.G.7    Borggrefe, M.8    Duber, C.9
  • 6
    • 33747186982 scopus 로고    scopus 로고
    • Cerebral microembolism during cardiac catheterization and risk of acute brain injury. A prospective diffusion weighted magnetic resonance imaging study
    • 10.1161/01.STR.0000231641.55843.49 16794203
    • Hamon M Gomes S Oppenheim C Morello R Sabatier R Lognoné T Grolier G Courtheoux P Hamon M Cerebral microembolism during cardiac catheterization and risk of acute brain injury. A prospective diffusion weighted magnetic resonance imaging study stroke 2006 37 2035-2038 10.1161/01.STR.0000231641.55843.49 16794203
    • (2006) Stroke , vol.37 , pp. 2035-2038
    • Hamon, M.1    Gomes, S.2    Oppenheim, C.3    Morello, R.4    Sabatier, R.5    Lognoné, T.6    Grolier, G.7    Courtheoux, P.8    Hamon, M.9
  • 9
    • 0031761429 scopus 로고    scopus 로고
    • Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty
    • 9804650
    • Bladin CF Bingham L Grigg L Yapanis AG Gerraty R Davis SM Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty Stroke 1998 29 2367-70 9804650
    • (1998) Stroke , vol.29 , pp. 2367-2370
    • Bladin, C.F.1    Bingham, L.2    Grigg, L.3    Yapanis, A.G.4    Gerraty, R.5    Davis, S.M.6
  • 10
    • 28344433262 scopus 로고    scopus 로고
    • Cerebral ischemic injury and cognitive impairment after off-pump and on-pump coronary artery bypass grafting surgery
    • 10.1016/j.athoracsur.2005.06.012 16305857
    • Lund C Sundet K Tennoe B Hol PK Rein KA Fosse E Russell D Cerebral ischemic injury and cognitive impairment after off-pump and on-pump coronary artery bypass grafting surgery Ann Thorac Surg 2005 80 2126-31 10.1016/j.athoracsur.2005.06.012 16305857
    • (2005) Ann Thorac Surg , vol.80 , pp. 2126-2131
    • Lund, C.1    Sundet, K.2    Tennoe, B.3    Hol, P.K.4    Rein, K.A.5    Fosse, E.6    Russell, D.7
  • 12
    • 0033952653 scopus 로고    scopus 로고
    • Aortic atheroma morphology and the risk of ischemic stroke in a multiethnic population
    • 10.1067/mhj.2000.101225 10650307
    • Di Tullio MR Sacco RL Savoia MT Sciacca RR Homma S Aortic atheroma morphology and the risk of ischemic stroke in a multiethnic population Am Heart J 2000 139 329-36 10.1067/mhj.2000.101225 10650307
    • (2000) Am Heart J , vol.139 , pp. 329-336
    • Di Tullio, M.R.1    Sacco, R.L.2    Savoia, M.T.3    Sciacca, R.R.4    Homma, S.5
  • 13
    • 0030641029 scopus 로고    scopus 로고
    • Frequency and distribution of atherosclerotic plaques in the thoracic aorta as determined by transesophageal echocardiography in patients with coronary artery disease
    • 10.1016/S0002-9149(96)00670-4 9024730
    • Khoury Z Gottlieb S Stern S Keren A Frequency and distribution of atherosclerotic plaques in the thoracic aorta as determined by transesophageal echocardiography in patients with coronary artery disease Am J Cardiol 1997 79 23-7 10.1016/S0002-9149(96)00670-4 9024730
    • (1997) Am J Cardiol , vol.79 , pp. 23-27
    • Khoury, Z.1    Gottlieb, S.2    Stern, S.3    Keren, A.4
  • 14
    • 0029936018 scopus 로고    scopus 로고
    • Risk of catheter-related emboli in patients with atherosclerotic debris in the thoracic aorta
    • 10.1016/S0002-8703(96)90090-3 8644594
    • Karalis DG Quinn V Victor MF Ross JJ Polansky M Spratt KA Chandrasekaran K Risk of catheter-related emboli in patients with atherosclerotic debris in the thoracic aorta Am Heart J 1996 131 1149-55 10.1016/ S0002-8703(96)90090-3 8644594
    • (1996) Am Heart J , vol.131 , pp. 1149-1155
    • Karalis, D.G.1    Quinn, V.2    Victor, M.F.3    Ross, J.J.4    Polansky, M.5    Spratt, K.A.6    Chandrasekaran, K.7
  • 15
    • 3142582426 scopus 로고    scopus 로고
    • Should we cross the valve: The risk of retrograde catheterization of the left ventricle in patients with aortic stenosis
    • 10.1016/j.ahj.2004.05.031 15215790
    • Meine TJ Harrison JK Should we cross the valve: The risk of retrograde catheterization of the left ventricle in patients with aortic stenosis Am Heart J 2004 148 41-42 10.1016/j.ahj.2004.05.031 15215790
    • (2004) Am Heart J , vol.148 , pp. 41-42
    • Meine, T.J.1    Harrison, J.K.2
  • 17
    • 0036197195 scopus 로고    scopus 로고
    • Power M-mode Doppler for observing cerebral blood flow and tracking emboli
    • 10.1016/S0301-5629(01)00486-0
    • Moehring MA Spencer MP Power M-mode Doppler for observing cerebral blood flow and tracking emboli Ultrasound in Med and Biol 2002 49-57 10.1016/ S0301-5629(01)00486-0
    • (2002) Ultrasound in Med and Biol , pp. 49-57
    • Moehring, M.A.1    Spencer, M.P.2
  • 18
    • 0029041693 scopus 로고
    • Basic Identification Criteria of Doppler Microembolic Signals
    • Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium 7762033
    • Basic Identification Criteria of Doppler Microembolic Signals. Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium Stroke 1995 26 1123 7762033
    • (1995) Stroke , vol.26 , pp. 1123
  • 19
    • 0032377357 scopus 로고    scopus 로고
    • Approximate is better than exact for interval estimation of binomial proportions
    • 10.2307/2685469
    • Agresti A Coull BA Approximate is better than exact for interval estimation of binomial proportions The American Statistician 1998 52 119-126 10.2307/2685469
    • (1998) The American Statistician , vol.52 , pp. 119-126
    • Agresti, A.1    Coull, B.A.2
  • 20
    • 10044251063 scopus 로고    scopus 로고
    • Neuropsychological outcome after percutaneous coronary intervention or coronary artery bypass grafting: Results from the Stent or Surgery (SoS) Trial
    • 10.1161/01.CIR.0000148366.80443.2B 15557380
    • Wahrborg P Booth JE Clayton T Nugara F Pepper J Weintraub WS Sigwart U Stables RH Neuropsychological outcome after percutaneous coronary intervention or coronary artery bypass grafting: Results from the Stent or Surgery (SoS) Trial Circulation 2004 110 3411-7 10.1161/ 01.CIR.0000148366.80443.2B 15557380
    • (2004) Circulation , vol.110 , pp. 3411-3417
    • Wahrborg, P.1    Booth, J.E.2    Clayton, T.3    Nugara, F.4    Pepper, J.5    Weintraub, W.S.6    Sigwart, U.7    Stables, R.H.8
  • 22
    • 0027762794 scopus 로고
    • Stroke complicating percutaneous coronary revascularization
    • 10.1016/0002-9149(93)90998-R 8237818
    • Brown DL Topol EJ Stroke complicating percutaneous coronary revascularization Am J Cardiol 1993 72 1207-1209 10.1016/ 0002-9149(93)90998-R 8237818
    • (1993) Am J Cardiol , vol.72 , pp. 1207-1209
    • Brown, D.L.1    Topol, E.J.2
  • 24
    • 0031688743 scopus 로고    scopus 로고
    • Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization
    • 10.1016/S0002-9149(98)00407-X 9732893
    • Braekken SK Endresen K Russel D Brucher R Kjekshus J Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization Am J Cardiol 1998 82 632-637 10.1016/S0002-9149(98)00407-X 9732893
    • (1998) Am J Cardiol , vol.82 , pp. 632-637
    • Braekken, S.K.1    Endresen, K.2    Russel, D.3    Brucher, R.4    Kjekshus, J.5
  • 25
    • 0032406941 scopus 로고    scopus 로고
    • Scraping of aortic debris by coronary guiding catheters: A prospective evaluation of 1,000 cases
    • 10.1016/S0735-1097(98)00497-5 9857864
    • Keeley EC Grines CL Scraping of aortic debris by coronary guiding catheters: A prospective evaluation of 1,000 cases J Am Coll Cardiol 1998 32 1861-5 10.1016/S0735-1097(98)00497-5 9857864
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1861-1865
    • Keeley, E.C.1    Grines, C.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.