메뉴 건너뛰기




Volumn 32, Issue 2, 2007, Pages 291-294

Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro study

Author keywords

Aortic valve; Coronary artery flow; Percutaneous; Replacement

Indexed keywords

COBALT; NICKEL;

EID: 34347384722     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2007.04.033     Document Type: Article
Times cited : (37)

References (12)
  • 1
    • 0026562077 scopus 로고
    • Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs
    • Andersen H.R., Knudsen L.L., and Hasenkam J.M. Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. Eur Heart J 13 (1992) 704-708
    • (1992) Eur Heart J , vol.13 , pp. 704-708
    • Andersen, H.R.1    Knudsen, L.L.2    Hasenkam, J.M.3
  • 3
    • 0037065848 scopus 로고    scopus 로고
    • Steps toward percutaneous aortic valve replacement
    • Boudjemline Y., and Bonhoeffer P. Steps toward percutaneous aortic valve replacement. Circulation 105 (2002) 775-778
    • (2002) Circulation , vol.105 , pp. 775-778
    • Boudjemline, Y.1    Bonhoeffer, P.2
  • 4
    • 22044445688 scopus 로고    scopus 로고
    • Direct-access valve replacement: a novel approach for off-pump valve implantation using valved stents
    • Huber C.H., Cohn L.H., and von Segesser L.K. Direct-access valve replacement: a novel approach for off-pump valve implantation using valved stents. J Am Coll Cardiol 46 (2005) 366-370
    • (2005) J Am Coll Cardiol , vol.46 , pp. 366-370
    • Huber, C.H.1    Cohn, L.H.2    von Segesser, L.K.3
  • 7
  • 8
    • 0027134908 scopus 로고
    • Porcine aortic leaflet arrangement may contribute to clinical xenograft failure
    • Grande K.J., Kunzelman K.S., Cochran R.P., David T.E., and Verrier E.D. Porcine aortic leaflet arrangement may contribute to clinical xenograft failure. ASAIO J 39 (1993) 918-922
    • (1993) ASAIO J , vol.39 , pp. 918-922
    • Grande, K.J.1    Kunzelman, K.S.2    Cochran, R.P.3    David, T.E.4    Verrier, E.D.5
  • 12
    • 33748937701 scopus 로고    scopus 로고
    • A repositionable valved stent for endovascular treatment of deteriorated bioprostheses
    • Zegdi R., Khabbaz Z., Borenstein N., and Fabiani J.-N. A repositionable valved stent for endovascular treatment of deteriorated bioprostheses. J Am Coll Cardiol 48 (2006) 1365-1368
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1365-1368
    • Zegdi, R.1    Khabbaz, Z.2    Borenstein, N.3    Fabiani, J.-N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.