메뉴 건너뛰기




Volumn 6, Issue 3, 2007, Pages 197-203

Intensity-modulated radiosurgery: Improving dose gradients and maximum dose using post inverse-optimization interactive dose shaping

Author keywords

Comparison; Dose shaping; Intensity modulated radiosurgery; Inverse treatment planning; Optimization

Indexed keywords

ARTERIOVENOUS MALFORMATION; ARTICLE; BRAIN METASTASIS; CLINICAL ARTICLE; COMPUTER PROGRAM; HUMAN; INTENSITY MODULATED RADIATION THERAPY; LINEAR ACCELERATOR; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 34347377144     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.1177/153303460700600307     Document Type: Article
Times cited : (8)

References (19)
  • 2
    • 0034433344 scopus 로고    scopus 로고
    • A quality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape. Technical note
    • Borden JA, Mahajan A, Tsai JS. A quality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape. Technical note. Journal of Neurosurgery 93, 228-232 (2000).
    • (2000) Journal of Neurosurgery , vol.93 , pp. 228-232
    • Borden, J.A.1    Mahajan, A.2    Tsai, J.S.3
  • 5
    • 20044381876 scopus 로고    scopus 로고
    • Radiosurgery of small skull-base lesions no advantage for intensity-modulated stereotactic radiosurgery versus conformal arc technique
    • Ernst-Stecken A, Lambrecht U, Ganslandt O, et al. Radiosurgery of small skull-base lesions no advantage for intensity-modulated stereotactic radiosurgery versus conformal arc technique. Strahlenther Onkol 181, 336-344 (2005).
    • (2005) Strahlenther Onkol , vol.181 , pp. 336-344
    • Ernst-Stecken, A.1    Lambrecht, U.2    Ganslandt, O.3
  • 6
    • 0027171867 scopus 로고
    • Target dose versus extratarget dose in stereotactic radiosurgery
    • Lax I. Target dose versus extratarget dose in stereotactic radiosurgery. Acta Oncologica 32, 453-457 (1993).
    • (1993) Acta Oncologica , vol.32 , pp. 453-457
    • Lax, I.1
  • 8
    • 33749632801 scopus 로고    scopus 로고
    • Phase II trial of hypofractionated stereotactic radiotherapy for brain metastases: Results and toxicity
    • Ernst-Stecken A, Ganslandt O, Lambrecht U, Sauer R, Grabenbauer G. Phase II trial of hypofractionated stereotactic radiotherapy for brain metastases: results and toxicity. Radiother Oncol 81, 18-24 (2006).
    • (2006) Radiother Oncol , vol.81 , pp. 18-24
    • Ernst-Stecken, A.1    Ganslandt, O.2    Lambrecht, U.3    Sauer, R.4    Grabenbauer, G.5
  • 10
    • 26844445650 scopus 로고    scopus 로고
    • Intensity-modulated radiosurgery for childhood arteriovenous malformations
    • discussion 9-50
    • Fuss M, Salter BJ, Caron JL, Vollmer DG, Herman TS. Intensity-modulated radiosurgery for childhood arteriovenous malformations. Acta Neurochirurgica 147, 1141-1149; discussion 9-50 (2005).
    • (2005) Acta Neurochirurgica , vol.147 , pp. 1141-1149
    • Fuss, M.1    Salter, B.J.2    Caron, J.L.3    Vollmer, D.G.4    Herman, T.S.5
  • 12
    • 0034433104 scopus 로고    scopus 로고
    • A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note
    • Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. Journal of Neurosurgery 93, 219-222 (2000).
    • (2000) Journal of Neurosurgery , vol.93 , pp. 219-222
    • Paddick, I.1
  • 14
    • 33646256568 scopus 로고    scopus 로고
    • Dosimetric comparisons of helical tomotherapy treatment plans and step-and-shoot intensity-modulated radiosurgery treatment plans in intracranial stereotactic radiosurgery
    • Han C, Liu A, Schultheiss TE, Pezner RD, Chen YJ, Wong JY. Dosimetric comparisons of helical tomotherapy treatment plans and step-and-shoot intensity-modulated radiosurgery treatment plans in intracranial stereotactic radiosurgery. International Journal of Radiation Oncology, Biology, Physics 65, 608-616 (2006).
    • (2006) International Journal of Radiation Oncology, Biology, Physics , vol.65 , pp. 608-616
    • Han, C.1    Liu, A.2    Schultheiss, T.E.3    Pezner, R.D.4    Chen, Y.J.5    Wong, J.Y.6
  • 15
    • 0242414613 scopus 로고    scopus 로고
    • Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target
    • discussion 62-63
    • Yu C, Jozsef G, Apuzzo ML, Petrovich Z. Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target. Neurosurgery 53, 1155-1162; discussion 62-63 (2003).
    • (2003) Neurosurgery , vol.53 , pp. 1155-1162
    • Yu, C.1    Jozsef, G.2    Apuzzo, M.L.3    Petrovich, Z.4
  • 16
    • 34248328658 scopus 로고    scopus 로고
    • Dosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis
    • Penagaricano JA, Yan Y, Shi C, Linskey ME, Ratanatharathorn V. Dosimetric comparison of Helical Tomotherapy and Gamma Knife Stereotactic Radiosurgery for single brain metastasis. Radiation Oncology 1, (2006).
    • (2006) Radiation Oncology , vol.1
    • Penagaricano, J.A.1    Yan, Y.2    Shi, C.3    Linskey, M.E.4    Ratanatharathorn, V.5
  • 18
    • 33748848363 scopus 로고    scopus 로고
    • Tomotherapeutic stereotactic body radiation therapy: Techniques and comparison between modalities
    • Fuss M, Shi C, Papanikolaou N. Tomotherapeutic stereotactic body radiation therapy: Techniques and comparison between modalities. Acta Oncologica 45, 953-960 (2006).
    • (2006) Acta Oncologica , vol.45 , pp. 953-960
    • Fuss, M.1    Shi, C.2    Papanikolaou, N.3
  • 19
    • 0037393203 scopus 로고    scopus 로고
    • IMRT dose shaping with regionally variable penalty scheme
    • Cotrutz C, Xing L. IMRT dose shaping with regionally variable penalty scheme. Medical Physics 30, 544-551 (2003).
    • (2003) Medical Physics , vol.30 , pp. 544-551
    • Cotrutz, C.1    Xing, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.