-
1
-
-
0026191490
-
Ferro-resonance in power systems: Fundamental solutions
-
Marti R. Ferro-resonance in power systems: Fundamental solutions [J]. IEE Proceedings-C, 1991, 138 (4): 321.
-
(1991)
IEE Proceedings-C
, vol.138
, Issue.4
, pp. 321
-
-
Marti, R.1
-
3
-
-
0027602322
-
Ferro-resonance in power systems: Chaotic behaviour
-
Arujo A E A, Soudack A C. Ferro-resonance in power systems: Chaotic behaviour [J]. IEE Proceedings-C, 1993, 140 (3): 237-240.
-
(1993)
IEE Proceedings-C
, vol.140
, Issue.3
, pp. 237-240
-
-
Arujo, A.E.A.1
Soudack, A.C.2
-
4
-
-
0027664210
-
Experimental investigations of over-voltages in neutral isolated networks
-
Vukelja P L, Naumov R M, Vucinic M M, et al. Experimental investigations of over-voltages in neutral isolated networks [J]. IEE Proceedings-Generation, Transmission and Distribution, 1993, 140 (5): 343-350.
-
(1993)
IEE Proceedings-Generation, Transmission and Distribution
, vol.140
, Issue.5
, pp. 343-350
-
-
Vukelja, P.L.1
Naumov, R.M.2
Vucinic, M.M.3
-
5
-
-
29144452729
-
Mechanism of ferromagnetic resonance occurred in rural power system and its countermeasures
-
Jin Qiusheng. Mechanism of ferromagnetic resonance occurred in rural power system and its countermeasures [J]. Power System Technology, 2001, 25 (6): 61-63.
-
(2001)
Power System Technology
, vol.25
, Issue.6
, pp. 61-63
-
-
Jin, Q.1
-
6
-
-
20444434000
-
Study on Ferroresonance due to electromagnetic PT in ungrounded neutral system
-
Zhu Xukai, Yang Yihan, Lian Hongbo, et al. Study on Ferroresonance due to electromagnetic PT in ungrounded neutral system [C]. 2004 International Conference on Power System Technology, 2004, 1: 924-929.
-
(2004)
2004 International Conference on Power System Technology
, vol.1
, pp. 924-929
-
-
Zhu, X.1
Yang, Y.2
Lian, H.3
-
7
-
-
34347226928
-
-
Chinese source
-
-
-
-
8
-
-
34347206207
-
-
Chinese source
-
-
-
-
9
-
-
33746500070
-
Simulating test on effects of V-I characteristic of electromagnetic voltage transformer on ferro-resonance
-
Xu Yong. Simulating test on effects of V-I characteristic of electromagnetic voltage transformer on ferro-resonance [J]. High Voltage Engineering, 1997, 23 (4): 61-64.
-
(1997)
High Voltage Engineering
, vol.23
, Issue.4
, pp. 61-64
-
-
Xu, Y.1
-
10
-
-
34347227285
-
Analysis and study on suppression of ferromagnetic resonance in neutral ungrounded system
-
Zhou Lixia, Yin Zhongdong, et al. Analysis and study on suppression of ferromagnetic resonance in neutral ungrounded system [J]. Sichuan Electric Power Technology, 2005, 28 (4): 11-12, 14.
-
(2005)
Sichuan Electric Power Technology
, vol.28
, Issue.4
-
-
Zhou, L.1
Yin, Z.2
-
11
-
-
84883007054
-
Study on resonance over-voltage due to saturated PT in distribution system of Yulin power supply company in Guangxi
-
Xie Weishan, Lu Tiecheng, et al. Study on resonance over-voltage due to saturated PT in distribution system of Yulin power supply company in Guangxi [J]. Guangxi Electricity, 2002 (3): 24-29.
-
(2002)
Guangxi Electricity
, Issue.3
, pp. 24-29
-
-
Xie, W.1
Lu, T.2
-
12
-
-
34347263596
-
PT resonance in distribution systems and a new suppression method
-
Lu Tiecheng, Chen Weixian. PT resonance in distribution systems and a new suppression method [J]. High Voltage Engineering, 1998, 24 (3): 13-16.
-
(1998)
High Voltage Engineering
, vol.24
, Issue.3
, pp. 13-16
-
-
Lu, T.1
Chen, W.2
-
13
-
-
29144499818
-
The digital simulation and study of TV ferro-resonance over-voltage in 10 kV power network
-
Xu Zhilong, Huang Jianhua, Wang Dazhong. The digital simulation and study of TV ferro-resonance over-voltage in 10 kV power network [J]. Electric Power Equipment, 2001, 21 (2): 27-29, 38.
-
(2001)
Electric Power Equipment
, vol.21
, Issue.2
-
-
Xu, Z.1
Huang, J.2
Wang, D.3
-
14
-
-
29144437849
-
Comparative study on ferro-resonance elimination measures in 10kV power distribution system by simulation method
-
Zhou Hao, Yu Yuhong, et al. Comparative study on ferro-resonance elimination measures in 10kV power distribution system by simulation method [J]. Power System Technology, 2005, 29 (22): 24-34.
-
(2005)
Power System Technology
, vol.29
, Issue.22
, pp. 24-34
-
-
Zhou, H.1
Yu, Y.2
-
15
-
-
29144462903
-
Study on simulation calculation of ferro-resonance elimination in power distribution system
-
Ge Dong, Lu Tiecheng, Wang Ping. Study on simulation calculation of ferro-resonance elimination in power distribution system [J]. High Voltage Engineering, 2003, 29 (11): 15-17.
-
(2003)
High Voltage Engineering
, vol.29
, Issue.11
, pp. 15-17
-
-
Ge, D.1
Lu, T.2
Wang, P.3
|