메뉴 건너뛰기




Volumn 87, Issue 13, 2007, Pages 881-884

Intraoperative microvascular Doppler ultrasonography monitoring in intracranial aneurysm surgery

Author keywords

Blood flow velocity; Doppler ultrasonography; Intracranial aneurysm; Intraoperative monitoring

Indexed keywords

ADULT; AGED; ANEURYSM CLIP; ANEURYSM SURGERY; ANTERIOR COMMUNICATING ARTERY; ARTICLE; ARTIFICIAL EMBOLISM; BLOOD FLOW VELOCITY; BRAIN BLOOD FLOW; CAROTID ARTERY OBSTRUCTION; CLINICAL ARTICLE; CORRELATION ANALYSIS; DOPPLER ECHOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; INTERNAL CAROTID ARTERY; INTERNAL CAROTID ARTERY ANEURYSM; INTRACRANIAL ANEURYSM; MALE; PATIENT MONITORING; RELIABILITY; STENOSIS; TREATMENT FAILURE;

EID: 34250859421     PISSN: 03762491     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0034018881 scopus 로고    scopus 로고
    • Intraoperative microvascular Doppler ultra-sonography in cerebral aneurysm surgery
    • Stendel R, Pietila T, Al Hassan, et al. Intraoperative microvascular Doppler ultra-sonography in cerebral aneurysm surgery. J Neurology Neurosurgery Psychiatry, 2000,68:29-35.
    • (2000) J Neurology Neurosurgery Psychiatry , vol.68 , pp. 29-35
    • Stendel, R.1    Pietila, T.2    Hassan, A.3
  • 2
    • 33646196626 scopus 로고    scopus 로고
    • The utility of intraoperative blood flow measurement during aneurysm surgery using an ultrasonic perivascular flow probe
    • Sepideh AH, Guido M, Rodolfo G, et al. The utility of intraoperative blood flow measurement during aneurysm surgery using an ultrasonic perivascular flow probe. J Neurosurg, 2006, 58:305-112.
    • (2006) J Neurosurg , vol.58 , pp. 305-112
    • Sepideh, A.H.1    Guido, M.2    Rodolfo, G.3
  • 3
    • 0020394689 scopus 로고
    • Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
    • Aaslid R, Markwalder TM, Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg,1982, 57: 769-774.
    • (1982) J Neurosurg , vol.57 , pp. 769-774
    • Aaslid, R.1    Markwalder, T.M.2    Nornes, H.3
  • 4
    • 0025948827 scopus 로고
    • Neurosurgical vascular complications associated with aneurysm clips evaluated by post-mortem angiography
    • Karhunen PJ. Neurosurgical vascular complications associated with aneurysm clips evaluated by post-mortem angiography. Forensic Sci Int, 1991, 51:13-22.
    • (1991) Forensic Sci Int , vol.51 , pp. 13-22
    • Karhunen, P.J.1
  • 6
    • 0025004329 scopus 로고
    • Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations
    • Martin NA, Bentson J, Vixuela F, et al. Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations. J Neurosurg, 1990, 73: 526-533.
    • (1990) J Neurosurg , vol.73 , pp. 526-533
    • Martin, N.A.1    Bentson, J.2    Vixuela, F.3
  • 7
    • 0028330845 scopus 로고
    • Evoked potential monitoring during posterior fossa aneurysm surgery: A comparison of two modalities
    • Manninen PH, Patterson S, Lam AM, et al. Evoked potential monitoring during posterior fossa aneurysm surgery: a comparison of two modalities. Can J Anaesth, 1994,41:92-97.
    • (1994) Can J Anaesth , vol.41 , pp. 92-97
    • Manninen, P.H.1    Patterson, S.2    Lam, A.M.3
  • 8
    • 29744451315 scopus 로고    scopus 로고
    • Intraoperative Monitoring during Aneurysm Surgery as a Neuroprotective Activity with Reference to Evoked Potential and Microvascular Doppler Techniques
    • Sanzenbacher, Karl E. Intraoperative Monitoring during Aneurysm Surgery as a Neuroprotective Activity with Reference to Evoked Potential and Microvascular Doppler Techniques. Ann Ny Acad Sci, 2005,1053:28-29.
    • (2005) Ann Ny Acad Sci , vol.1053 , pp. 28-29
    • Sanzenbacher1    Karl, E.2
  • 9
    • 0842309202 scopus 로고    scopus 로고
    • False negative findings in intraoperative SEP monitoring: Analysis of 658 consecutive neurosurgical cases and review of published reports
    • Wiedemayer H, Sandalcioglu IE, Armbruster, W, et al. False negative findings in intraoperative SEP monitoring: analysis of 658 consecutive neurosurgical cases and review of published reports. J Neurology, Neurosurgery Psychiatry, 2004,75:280-286.
    • (2004) J Neurology, Neurosurgery Psychiatry , vol.75 , pp. 280-286
    • Wiedemayer, H.1    Sandalcioglu, I.E.2    Armbruster, W.3
  • 10
    • 34250823259 scopus 로고    scopus 로고
    • Chinese source.
    • Chinese source.
  • 11
    • 0030920289 scopus 로고    scopus 로고
    • Intraoperative microvascular Doppler sonography in aneurysm surgery
    • Bailes JE, Tantuwaya LS, Fukushima T, et al. Intraoperative microvascular Doppler sonography in aneurysm surgery. Neurosurgery, 1997, 40:965-970.
    • (1997) Neurosurgery , vol.40 , pp. 965-970
    • Bailes, J.E.1    Tantuwaya, L.S.2    Fukushima, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.