메뉴 건너뛰기




Volumn 54, Issue 3, 2007, Pages 710-717

Gamma-ray compton imaging of multitracer in biological samples using strip germanium telescope

Author keywords

Biomedical nuclear imaging; Compton camera; Germanium radiation detectors; Multitracer

Indexed keywords

BIOACTIVITY; GAMMA RAYS; GERMANIUM; SENSORS; THREE DIMENSIONAL; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 34250780358     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2007.894209     Document Type: Article
Times cited : (43)

References (20)
  • 2
    • 34250747171 scopus 로고    scopus 로고
    • Development of multitracer technology and application studies on biotrace element research
    • S. Enomoto, "Development of multitracer technology and application studies on biotrace element research," Biomed. Res. Trace Elem., vol. 16, pp. 233-240, 2005.
    • (2005) Biomed. Res. Trace Elem , vol.16 , pp. 233-240
    • Enomoto, S.1
  • 3
    • 0015604317 scopus 로고
    • A telescope for soft gamma ray astronomy
    • V. Schönfelder, "A telescope for soft gamma ray astronomy," Nucl. Instrum. Methods, vol. 107, pp. 385-394, 1973.
    • (1973) Nucl. Instrum. Methods , vol.107 , pp. 385-394
    • Schönfelder, V.1
  • 5
    • 0038203963 scopus 로고
    • Gamma-ray imaging with Compton cameras
    • O. W. Phillips, "Gamma-ray imaging with Compton cameras," Nucl. Instrum. Methods Phys. Res. B, vol. B99, pp. 674-677, 1995.
    • (1995) Nucl. Instrum. Methods Phys. Res. B , vol.B99 , pp. 674-677
    • Phillips, O.W.1
  • 7
    • 0037149913 scopus 로고    scopus 로고
    • Monte Carlo simulations of the performance of a Compton camera consisting of position sensitive germanium detectors
    • Y. F. Yang, Y. Gono, S. Motomura, S. Enomoto, and Y. Yano, "Monte Carlo simulations of the performance of a Compton camera consisting of position sensitive germanium detectors," Nucl. Instrum. Methods Phys. Res. A, vol. A482, pp. 806-813, 2002.
    • (2002) Nucl. Instrum. Methods Phys. Res. A , vol.A482 , pp. 806-813
    • Yang, Y.F.1    Gono, Y.2    Motomura, S.3    Enomoto, S.4    Yano, Y.5
  • 8
    • 0033334824 scopus 로고    scopus 로고
    • Position resolution in a Ge-strip detector
    • M. Momayezi, W. K. Warburton, and R. Kroeger, "Position resolution in a Ge-strip detector," Proc. SPIE, vol. 3768, pp. 530-537, 1999.
    • (1999) Proc. SPIE , vol.3768 , pp. 530-537
    • Momayezi, M.1    Warburton, W.K.2    Kroeger, R.3
  • 9
    • 0034273330 scopus 로고    scopus 로고
    • Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors
    • M. Amman and P. N. Luke, "Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors," Nucl. Instrum. Methods Phys. Res. A, vol. A452, pp. 155-166, 2000.
    • (2000) Nucl. Instrum. Methods Phys. Res. A , vol.A452 , pp. 155-166
    • Amman, M.1    Luke, P.N.2
  • 12
    • 34250703981 scopus 로고    scopus 로고
    • Effect of electrode design on depth-of-interaction sensitivity in two-dimensionally segmented planar germanium detectors
    • to be submitted
    • S. Motomura, S. Enomoto, Y. Gono, and Y. Yano, "Effect of electrode design on depth-of-interaction sensitivity in two-dimensionally segmented planar germanium detectors," to be submitted.
    • Motomura, S.1    Enomoto, S.2    Gono, Y.3    Yano, Y.4
  • 13
    • 0031381165 scopus 로고    scopus 로고
    • The spatially-variant backprojection point kernel function of an energy-subtraction Compton scatter camera for medical imaging
    • Dec
    • R. C. Rohe, M. M. Sharfi, K. A. Kecevar, J. D. Valentine, and C. Bonnerave, "The spatially-variant backprojection point kernel function of an energy-subtraction Compton scatter camera for medical imaging," IEEE Trans. Nucl. Sci., vol. 44, no. 6, pp. 2477-2482, Dec. 1997.
    • (1997) IEEE Trans. Nucl. Sci , vol.44 , Issue.6 , pp. 2477-2482
    • Rohe, R.C.1    Sharfi, M.M.2    Kecevar, K.A.3    Valentine, J.D.4    Bonnerave, C.5
  • 14
    • 0015372442 scopus 로고
    • Iterative methods for the three-dimensional resonstruction of an object from projections
    • P. Gilbert, "Iterative methods for the three-dimensional resonstruction of an object from projections," J. Theor. Biol., vol. 36, pp. 105-117, 1972.
    • (1972) J. Theor. Biol , vol.36 , pp. 105-117
    • Gilbert, P.1
  • 16
    • 34250711567 scopus 로고    scopus 로고
    • Detector Description and Simulation Tool, GEANT, CERN, Geneva, 1993.
    • Detector Description and Simulation Tool, GEANT, CERN, Geneva, 1993.
  • 17
    • 0011146625 scopus 로고    scopus 로고
    • Tumor accumulation of radioactive trace elements: A multitracer study
    • H. Tamano, S. Enomoto, B. Liu, and A. Takeda, "Tumor accumulation of radioactive trace elements: A multitracer study," Biomed. Res. Trace Elem., vol. 12, pp. 96-101, 2001.
    • (2001) Biomed. Res. Trace Elem , vol.12 , pp. 96-101
    • Tamano, H.1    Enomoto, S.2    Liu, B.3    Takeda, A.4
  • 18
    • 0035988213 scopus 로고    scopus 로고
    • Preferential uptake of zinc, manganese and rubidium in rat brain tumor
    • H. Tamano, S. Enomoto, N. Oku, and A. Takeda, "Preferential uptake of zinc, manganese and rubidium in rat brain tumor," Nucl. Med. Biol., vol. 29, pp. 505-508, 2002.
    • (2002) Nucl. Med. Biol , vol.29 , pp. 505-508
    • Tamano, H.1    Enomoto, S.2    Oku, N.3    Takeda, A.4
  • 19
    • 0035393773 scopus 로고    scopus 로고
    • Zinc-65 imaging of rat brain tumors
    • A. Takeda, H. Tamano, S. Enomoto, and N. Oku, "Zinc-65 imaging of rat brain tumors," Cancer Res., vol. 61, pp. 5065-5069, 2001.
    • (2001) Cancer Res , vol.61 , pp. 5065-5069
    • Takeda, A.1    Tamano, H.2    Enomoto, S.3    Oku, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.