메뉴 건너뛰기




Volumn 54, Issue 7, 2007, Pages 1328-1332

Low-noise two-wired buffer electrodes for bioelectric amplifiers

Author keywords

Active electrodes; Bioelectric recordings; dc offset compensation; Instrumentation amplifier; Two wired electrodes

Indexed keywords

ELECTRIC POWER UTILIZATION; ELECTRODES; LOW NOISE AMPLIFIERS; OPERATIONAL AMPLIFIERS; TRANSISTORS;

EID: 34250778220     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2006.889781     Document Type: Article
Times cited : (31)

References (8)
  • 1
    • 0032266881 scopus 로고    scopus 로고
    • Active electrodes for EEG and evoked potential
    • W. H. Ko, H. K. Chang and Y. T. Zhang, Eds
    • W. H. Ko, H. K. Chang and Y. T. Zhang, Eds., "Active electrodes for EEG and evoked potential," in Proc. 20th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, 1998, vol. 4, pp. 2221-2224.
    • (1998) Proc. 20th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society , vol.4 , pp. 2221-2224
  • 2
    • 0026932483 scopus 로고
    • Clinical application of an active electrode using an operational amplifier
    • Oct
    • S. Nishimura, Y. Tomita, and T. Horiuchi, "Clinical application of an active electrode using an operational amplifier," IEEE Trans. Biomed. Eng., vol. 39, no. 10, pp. 1096-1099, Oct. 1992.
    • (1992) IEEE Trans. Biomed. Eng , vol.39 , Issue.10 , pp. 1096-1099
    • Nishimura, S.1    Tomita, Y.2    Horiuchi, T.3
  • 3
    • 0030314284 scopus 로고    scopus 로고
    • A simple active electrode for power line interference reduction in high resolution biopotential measurements
    • M. Fernandez and R. Pallas-Areny, H. Boom, C. Robinson, W. Rutten, M. Neuman, and H. Wijkstra, Eds
    • M. Fernandez and R. Pallas-Areny, H. Boom, C. Robinson, W. Rutten, M. Neuman, and H. Wijkstra, Eds., "A simple active electrode for power line interference reduction in high resolution biopotential measurements," in Proc. 18th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, 1997, vol. 1, pp. 97-98.
    • (1997) Proc. 18th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society , vol.1 , pp. 97-98
  • 5
    • 31544470380 scopus 로고    scopus 로고
    • A pseudodifferential amplifier for bioelectric events with DC-offset compensation using two-wired amplifying electrodes
    • Feb
    • T. Degen and H. Jäckel, "A pseudodifferential amplifier for bioelectric events with DC-offset compensation using two-wired amplifying electrodes," IEEE Trans. Biomed. Eng., vol. 53, no. 2, pp. 300-310, Feb. 2006.
    • (2006) IEEE Trans. Biomed. Eng , vol.53 , Issue.2 , pp. 300-310
    • Degen, T.1    Jäckel, H.2
  • 6
    • 0014303456 scopus 로고
    • Some new electrode techniques for long-term physiologic monitoring
    • P. C. Richardson, F. K. Coombs, and R. M. Adams, "Some new electrode techniques for long-term physiologic monitoring," Aerosp. Med., pp. 745-750, 1968.
    • (1968) Aerosp. Med , pp. 745-750
    • Richardson, P.C.1    Coombs, F.K.2    Adams, R.M.3
  • 7
    • 0026203935 scopus 로고
    • Common mode rejection ratio in differential amplifiers
    • Aug
    • R. Pallas-Areny and J. G. Webster, "Common mode rejection ratio in differential amplifiers," IEEE Trans. Instrum. Meas., vol. 40, no. 4, pp. 669-676, Aug. 1991.
    • (1991) IEEE Trans. Instrum. Meas , vol.40 , Issue.4 , pp. 669-676
    • Pallas-Areny, R.1    Webster, J.G.2
  • 8
    • 0026191735 scopus 로고
    • High-quality recording of bioelectric events. Part 2. low-noise, low-power multi-channel amplifier design
    • Jul
    • A. C. M. van Rijn, A. Peper, and C. A. Grimbergen, "High-quality recording of bioelectric events. Part 2. low-noise, low-power multi-channel amplifier design," Med. Biol. Eng. Comput., vol. 29, no. 4, pp. 433-440, Jul. 1991.
    • (1991) Med. Biol. Eng. Comput , vol.29 , Issue.4 , pp. 433-440
    • van Rijn, A.C.M.1    Peper, A.2    Grimbergen, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.