메뉴 건너뛰기




Volumn 18, Issue 4, 2007, Pages 279-283

Intacs for keratoconus

Author keywords

Complications; Femtosecond laser; Intacs; Keratoconus; Stability

Indexed keywords

CONTACT LENS; HISTOPATHOLOGY; HUMAN; KERATOCONUS; KERATOMILEUSIS; LASER; LONG TERM CARE; OPTICAL COHERENCE TOMOGRAPHY; PHOTOREFRACTIVE KERATECTOMY; PHYSICIAN; PRIORITY JOURNAL; REVIEW; SURGICAL TECHNIQUE;

EID: 34250748630     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICU.0b013e3281fc94a5     Document Type: Review
Times cited : (45)

References (23)
  • 1
    • 0034897408 scopus 로고    scopus 로고
    • INTACS inserts for treating keratoconus: One-year results
    • Colin J, Cochener B, Savary G, et al. INTACS inserts for treating keratoconus: one-year results. Ophthalmology 2001; 108:1409-1414.
    • (2001) Ophthalmology , vol.108 , pp. 1409-1414
    • Colin, J.1    Cochener, B.2    Savary, G.3
  • 2
    • 33748252470 scopus 로고    scopus 로고
    • INTACS for keratoconus
    • Clin, This is a comprehensive review article of the use of INTACS since its inception as a treatment for keratoconus
    • Rabinowitz YS. INTACS for keratoconus. Int Ophthalmol Clin 2006; 46:91-103. This is a comprehensive review article of the use of INTACS since its inception as a treatment for keratoconus.
    • (2006) Int Ophthalmol , vol.46 , pp. 91-103
    • Rabinowitz, Y.S.1
  • 3
    • 0036736393 scopus 로고    scopus 로고
    • Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis
    • Alio J, Salem T, Artola A, Osman A. Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis. J Cataract Refract Surg 2002; 28:1568-1574.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1568-1574
    • Alio, J.1    Salem, T.2    Artola, A.3    Osman, A.4
  • 5
    • 18844409792 scopus 로고    scopus 로고
    • Treating keratoconus with Intacs corneal ring segments
    • Hellstedt T, Makela J, Uusitalo R, et al. Treating keratoconus with Intacs corneal ring segments. J Refract Surg 2005; 21:236-246.
    • (2005) J Refract Surg , vol.21 , pp. 236-246
    • Hellstedt, T.1    Makela, J.2    Uusitalo, R.3
  • 6
    • 33744925904 scopus 로고    scopus 로고
    • Alio JL, Shabayek MH, Belda JI, et al. Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction. J Cataract Refract Surg 2006; 32:756-761. This article clearly demonstrates that patients with milder disease, an average keratometry reading of less than 53 D, do better than patients with more advanced disease.
    • Alio JL, Shabayek MH, Belda JI, et al. Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction. J Cataract Refract Surg 2006; 32:756-761. This article clearly demonstrates that patients with milder disease, an average keratometry reading of less than 53 D, do better than patients with more advanced disease.
  • 7
    • 33744831467 scopus 로고    scopus 로고
    • European clinical evaluation: Use of Intacs for the treatment of keratoconus
    • This article illustrates the safety of this procedure
    • Colin J. European clinical evaluation: use of Intacs for the treatment of keratoconus. J Cataract Refract Surg 2006; 32:747-755. This article illustrates the safety of this procedure.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 747-755
    • Colin, J.1
  • 8
    • 29744465625 scopus 로고    scopus 로고
    • Kanellopoulos AJ, Pe LH, Perry HD, Donnenfeld ED. Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus: efficacy and complications. Cornea 2006; 25:29-33. This article illustrates the potential for a high complication rate in patients with advanced disease and who are treated with the mechanical spreader.
    • Kanellopoulos AJ, Pe LH, Perry HD, Donnenfeld ED. Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus: efficacy and complications. Cornea 2006; 25:29-33. This article illustrates the potential for a high complication rate in patients with advanced disease and who are treated with the mechanical spreader.
  • 9
    • 33750105819 scopus 로고    scopus 로고
    • Rabinowitz YS, Li X, Ignacio TS, Maguen E. INTACS inserts using the femtosecond laser compared to the mechanical spreader in the treatment of keratoconus. J Refract Surg 2006; 22:764-771. This article for the first time describes the use of the femtosecond laser to create the channels for inserting Intacs and demonstrates that it is a superior procedure over the insertion of Intacs with a mechanical spreader.
    • Rabinowitz YS, Li X, Ignacio TS, Maguen E. INTACS inserts using the femtosecond laser compared to the mechanical spreader in the treatment of keratoconus. J Refract Surg 2006; 22:764-771. This article for the first time describes the use of the femtosecond laser to create the channels for inserting Intacs and demonstrates that it is a superior procedure over the insertion of Intacs with a mechanical spreader.
  • 10
    • 33751309178 scopus 로고    scopus 로고
    • Intacs insertion with the femtosecond laser for the management of keratoconus: One-year results
    • Ertan A, Kamburoglu G, Bahadir M. Intacs insertion with the femtosecond laser for the management of keratoconus: one-year results. J Cataract Refract Surg 2006; 32:2039-2042.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2039-2042
    • Ertan, A.1    Kamburoglu, G.2    Bahadir, M.3
  • 11
    • 33845653981 scopus 로고    scopus 로고
    • Intacs for the correction of keratoconus: Two-year follow-up
    • Colin J, Malet FJ. Intacs for the correction of keratoconus: two-year follow-up. J Cataract Refract Surg 2007; 33:69-74.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 69-74
    • Colin, J.1    Malet, F.J.2
  • 12
    • 33745450877 scopus 로고    scopus 로고
    • Intracorneal ring segments for keratoconus correction: Long-term follow-up
    • Alio JL, Shabayek MH, Artola A. Intracorneal ring segments for keratoconus correction: long-term follow-up. J Cataract Refract Surg 2006; 32:978-985.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 978-985
    • Alio, J.L.1    Shabayek, M.H.2    Artola, A.3
  • 13
    • 33846397431 scopus 로고    scopus 로고
    • Kymionis GD, Siganos CS, Tsiklis NS, et al. Long-term follow-up of Intacs in keratoconus. Am J Ophthalmol 2007; 143:236-244. This report describes the 5-year results after Intacs for keratoconus demonstrating a remarkable degree of stability.
    • Kymionis GD, Siganos CS, Tsiklis NS, et al. Long-term follow-up of Intacs in keratoconus. Am J Ophthalmol 2007; 143:236-244. This report describes the 5-year results after Intacs for keratoconus demonstrating a remarkable degree of stability.
  • 14
    • 33750321854 scopus 로고    scopus 로고
    • Kymionis GD, Tsiklis NS, Pallikaris AI, et al. Long-term follow-up of Intacs for post-LASIK corneal ectasia. Ophthalmology 2006; 113:1909-1917. This is a report of a 5-year follow up of Intacs for post-LASIK ectasia, also demonstrating safety and no evidence of progression.
    • Kymionis GD, Tsiklis NS, Pallikaris AI, et al. Long-term follow-up of Intacs for post-LASIK corneal ectasia. Ophthalmology 2006; 113:1909-1917. This is a report of a 5-year follow up of Intacs for post-LASIK ectasia, also demonstrating safety and no evidence of progression.
  • 15
    • 33645116761 scopus 로고    scopus 로고
    • Intracorneal asymmetrical rings for keratoconus: Where should the thicker segment be implanted?
    • Alio JL, Shabayek MH. Intracorneal asymmetrical rings for keratoconus: where should the thicker segment be implanted? J Refract Surg 2006; 22:307-309.
    • (2006) J Refract Surg , vol.22 , pp. 307-309
    • Alio, J.L.1    Shabayek, M.H.2
  • 16
    • 33846267292 scopus 로고    scopus 로고
    • Reduced best spectacle-corrected visual acuity from inserting a thicker Intacs above and thinner Intacs below in keratoconus
    • Chan CC, Wachler BS. Reduced best spectacle-corrected visual acuity from inserting a thicker Intacs above and thinner Intacs below in keratoconus. J Refract Surg 2007; 23:93-95.
    • (2007) J Refract Surg , vol.23 , pp. 93-95
    • Chan, C.C.1    Wachler, B.S.2
  • 17
    • 33646165355 scopus 로고    scopus 로고
    • Comparison of single-segment and double-segment Intacs for keratoconus and post-LASIK ectasia
    • This article demonstrates that a single segment is more effective than two segments for decreasing asymmetry in keratoconus
    • Sharma M, Boxer Wachler BS. Comparison of single-segment and double-segment Intacs for keratoconus and post-LASIK ectasia. Am J Ophthalmol 2006; 141:891-895. This article demonstrates that a single segment is more effective than two segments for decreasing asymmetry in keratoconus.
    • (2006) Am J Ophthalmol , vol.141 , pp. 891-895
    • Sharma, M.1    Boxer Wachler, B.S.2
  • 18
    • 33845678509 scopus 로고    scopus 로고
    • Topography-guided vertical implantation of Intacs using a femtosecond laser for the treatment of keratoconus
    • Ertan A, Bahadir T. Topography-guided vertical implantation of Intacs using a femtosecond laser for the treatment of keratoconus. J Cataract Refract Surg 2007; 33:148-151.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 148-151
    • Ertan, A.1    Bahadir, T.2
  • 19
    • 33745230771 scopus 로고    scopus 로고
    • Pokroy R, Levinger S. Intacs adjustment surgery for keratoconus. J Cataract Refract Surg 2006; 32:986-992. This article shows that in 10% of Intacs failures adjustment can result in a good outcome.
    • Pokroy R, Levinger S. Intacs adjustment surgery for keratoconus. J Cataract Refract Surg 2006; 32:986-992. This article shows that in 10% of Intacs failures adjustment can result in a good outcome.
  • 20
    • 33646098677 scopus 로고    scopus 로고
    • Wavefront-guided LASEK after Intacs in eyes with stable keratoconus
    • Hirsh A, Barequet IS, Levinger S. Wavefront-guided LASEK after Intacs in eyes with stable keratoconus. Harefuah 2006; 145:181-182.
    • (2006) Harefuah , vol.145 , pp. 181-182
    • Hirsh, A.1    Barequet, I.S.2    Levinger, S.3
  • 21
    • 33645835477 scopus 로고    scopus 로고
    • Contact lens fitting for keratoconus after Intacs placement
    • Ucakhan OO, Kanpolat A, Ozdemir O. Contact lens fitting for keratoconus after Intacs placement. Eye Contact Lens 2006; 32:75-77.
    • (2006) Eye Contact Lens , vol.32 , pp. 75-77
    • Ucakhan, O.O.1    Kanpolat, A.2    Ozdemir, O.3
  • 22
    • 33750465150 scopus 로고    scopus 로고
    • Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes
    • Lai MM, Tang M, Andrade EM, et al. Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes. J Cataract Refract Surg 2006; 32:1860-1865.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1860-1865
    • Lai, M.M.1    Tang, M.2    Andrade, E.M.3
  • 23
    • 33846632291 scopus 로고    scopus 로고
    • Histopathological findings after intracorneal ring segment implantation in keratoconic human corneas
    • Samimi S, Leger F, Touboul D, Colin J. Histopathological findings after intracorneal ring segment implantation in keratoconic human corneas. J Cataract Refract Surg 2007; 33:247-253.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 247-253
    • Samimi, S.1    Leger, F.2    Touboul, D.3    Colin, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.