-
1
-
-
0032750461
-
Technique for resolution of graft-tunnel length mismatch in central third bone-patellar tendon-bone anterior cruciate ligament reconstruction
-
Auge WK II, Yifan K.A. technique for resolution of graft-tunnel length mismatch in central third bone-patellar tendon-bone anterior cruciate ligament reconstruction. Arthroscopy. 1999 ; 15: 877-881.
-
(1999)
Arthroscopy.
, vol.15
, pp. 877-881
-
-
Auge II, W.K.1
Yifan, K.A.2
-
2
-
-
0034234702
-
Flipped patellar tendon autograft anterior cruciate ligament reconstruction
-
Barber FA Flipped patellar tendon autograft anterior cruciate ligament reconstruction. Arthroscopy. 2000 ; 16: 483-490.
-
(2000)
Arthroscopy
, vol.16
, pp. 483-490
-
-
Barber, F.A.1
-
3
-
-
0037386325
-
Should allografts be used for routine anterior cruciate ligament reconstructions?
-
Barber FA, McGuire DA, Johnson DH Should allografts be used for routine anterior cruciate ligament reconstructions? Arthroscopy. 2003 ; 19: 421-425.
-
(2003)
Arthroscopy
, vol.19
, pp. 421-425
-
-
Barber, F.A.1
McGuire, D.A.2
Johnson, D.H.3
-
5
-
-
0031615953
-
Graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction: Intraoperative and cadaver measurement of the intra-articular graft length and the length of the patellar tendon
-
Denti M., Bigoni M., Randelli P., et al. Graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction: intraoperative and cadaver measurement of the intra-articular graft length and the length of the patellar tendon. Knee Surg Sports Traumatol Arthrosc. 1998 ; 6: 165-168.
-
(1998)
Knee Surg Sports Traumatol Arthrosc
, vol.6
, pp. 165-168
-
-
Denti, M.1
Bigoni, M.2
Randelli, P.3
-
6
-
-
33646150884
-
Variation in the length of the tibial tunnel in anterior cruciate ligament reconstruction: Is it safe to use a 35 mm screw?
-
Figueroa D., Calvo R., Vaisman A. Variation in the length of the tibial tunnel in anterior cruciate ligament reconstruction: is it safe to use a 35 mm screw? Arthroscopy. 2006 ; 22: 573.
-
(2006)
Arthroscopy
, vol.22
, pp. 573
-
-
Figueroa, D.1
Calvo, R.2
Vaisman, A.3
-
7
-
-
0036821551
-
Allograft anterior cruciate ligament reconstruction in patients over 40 years of age
-
Kuechle DK, Pearson SE, Beach WR, et al. Allograft anterior cruciate ligament reconstruction in patients over 40 years of age. Arthroscopy. 2002 ; 18: 845-853.
-
(2002)
Arthroscopy
, vol.18
, pp. 845-853
-
-
Kuechle, D.K.1
Pearson, S.E.2
Beach, W.R.3
-
8
-
-
0032612024
-
Formula to calculate the length of the tibial tunnel with endoscopic ACL reconstruction to avoid graft-tunnel mismatch
-
Kurzweil PR Formula to calculate the length of the tibial tunnel with endoscopic ACL reconstruction to avoid graft-tunnel mismatch. Arthroscopy. 1999 ; 15: 115-117.
-
(1999)
Arthroscopy
, vol.15
, pp. 115-117
-
-
Kurzweil, P.R.1
-
9
-
-
0030051840
-
The "n + 7 rule" for tibial tunnel placement in endoscopic anterior cruciate ligament reconstruction
-
Miller MD, Hinkin DT The "N + 7 rule" for tibial tunnel placement in endoscopic anterior cruciate ligament reconstruction. Arthroscopy. 1996 ; 12: 124-126.
-
(1996)
Arthroscopy
, vol.12
, pp. 124-126
-
-
Miller, M.D.1
Hinkin, D.T.2
-
10
-
-
0031886688
-
Ideal tibial tunnel length for endoscopic anterior cruciate ligament reconstruction
-
Olszewski AD, Miller MD, Ritchie JR Ideal tibial tunnel length for endoscopic anterior cruciate ligament reconstruction. Arthroscopy. 1998 ; 14: 9-14.
-
(1998)
Arthroscopy.
, vol.14
, pp. 9-14
-
-
Olszewski, A.D.1
Miller, M.D.2
Ritchie, J.R.3
-
11
-
-
0035166493
-
Allograft versus autograft patellar tendon anterior cruciate ligament reconstruction: A 5 year follow-up
-
Peterson RK, Shelton WR, Bomboy AL Allograft versus autograft patellar tendon anterior cruciate ligament reconstruction: a 5 year follow-up. Arthroscopy. 2001 ; 17: 9-13.
-
(2001)
Arthroscopy
, vol.17
, pp. 9-13
-
-
Peterson, R.K.1
Shelton, W.R.2
Bomboy, A.L.3
-
12
-
-
0027769636
-
Graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction: A new technique of intraarticular measurement and modified graft harvesting
-
Shaffer B., Gow W., Tibone JE Graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction: a new technique of intraarticular measurement and modified graft harvesting. Arthroscopy. 1993 ; 9: 633-646.
-
(1993)
Arthroscopy
, vol.9
, pp. 633-646
-
-
Shaffer, B.1
Gow, W.2
Tibone, J.E.3
-
13
-
-
0346220024
-
Arthroscopic allograft surgery of the knee and shoulder: Indications, techniques, and risks
-
Shelton WR Arthroscopic allograft surgery of the knee and shoulder: indications, techniques, and risks. Arthroscopy. 2003 ; 19: 67-69.
-
(2003)
Arthroscopy
, vol.19
, pp. 67-69
-
-
Shelton, W.R.1
-
14
-
-
0032060913
-
Use of allografts in knee reconstruction: Surgical considerations
-
Shelton WR, Treacy SH, Dukes AD Use of allografts in knee reconstruction: surgical considerations. J Am Acad Orthop Surg. 1998 ; 6: 169-175.
-
(1998)
J Am Acad Orthop Surg.
, vol.6
, pp. 169-175
-
-
Shelton, W.R.1
Sh, T.2
Dukes, A.D.3
-
15
-
-
0027416034
-
Intraoperative complications of ACL surgery: Avoidance and management
-
Spindler KP, Bergfeld JA, Andrish JT Intraoperative complications of ACL surgery: avoidance and management. Orthopedics. 1993 ; 16: 425-430.
-
(1993)
Orthopedics.
, vol.16
, pp. 425-430
-
-
Kp, S.1
Bergfeld, J.A.2
Andrish, J.T.3
-
16
-
-
26944452492
-
Bach BR Jr. Preliminary clinical results of two techniques for addressing graft tunnel mismatch in endoscopic anterior cruciate ligament reconstruction
-
Verma NN, Dennis MG, Carreira DS, Bojchuk J., Hayden JK, Bach BR Jr. Preliminary clinical results of two techniques for addressing graft tunnel mismatch in endoscopic anterior cruciate ligament reconstruction. J Knee Surg. 2005 ; 18: 183-191.
-
(2005)
J Knee Surg.
, vol.18
, pp. 183-191
-
-
Verma, N.N.1
Dennis, M.G.2
Carreira, D.S.3
Bojchuk, J.4
Hayden, J.K.5
|