메뉴 건너뛰기




Volumn 70, Issue 1, 2007, Pages 112-118

Rapid and sensitive magnetoelastic biosensors for the detection of Salmonella typhimurium in a mixed microbial population

Author keywords

Biosensor; Magnetoelastic; Polyclonal antibodies; Salmonella typhimurium; Specificity

Indexed keywords

ARTICLE; BACTERIUM DETECTION; BINDING KINETICS; BIOSENSOR; CONTROLLED STUDY; DISSOCIATION CONSTANT; ESCHERICHIA COLI; IMMOBILIZATION; LANGMUIR BLODGETT FILM; LISTERIA MONOCYTOGENES; NONHUMAN; PRIORITY JOURNAL; SALMONELLA TYPHIMURIUM; SENSITIVITY AND SPECIFICITY; WATER SAMPLING;

EID: 34250746464     PISSN: 01677012     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mimet.2007.04.001     Document Type: Article
Times cited : (61)

References (25)
  • 1
    • 0025718806 scopus 로고
    • Polymerase chain reaction-gene probe detection of microorganisms by using filter-concentrated samples
    • Bej A.K., Mahbubani M.H., Dicesare J.L., and Atlas R.M. Polymerase chain reaction-gene probe detection of microorganisms by using filter-concentrated samples. Appl. Environ. Microbiol. 57 12 (1991) 3529-3534
    • (1991) Appl. Environ. Microbiol. , vol.57 , Issue.12 , pp. 3529-3534
    • Bej, A.K.1    Mahbubani, M.H.2    Dicesare, J.L.3    Atlas, R.M.4
  • 2
    • 22944485015 scopus 로고    scopus 로고
    • The real-time, in situ monitoring of calcium oxalate and brushite precipitation using magnetoelastic sensors
    • Bouropoulos N., Kouzoudis D., and Grimes C.A. The real-time, in situ monitoring of calcium oxalate and brushite precipitation using magnetoelastic sensors. Sens. Actuators, B, Chem. 109 (2005) 227-232
    • (2005) Sens. Actuators, B, Chem. , vol.109 , pp. 227-232
    • Bouropoulos, N.1    Kouzoudis, D.2    Grimes, C.A.3
  • 3
    • 0030333569 scopus 로고    scopus 로고
    • Immunoelectrochemical assays for bacteria: use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella
    • Brewster J.D., Gehring A.G., Mazenko R.S., Van Houten L.J., and Crawford C.J. Immunoelectrochemical assays for bacteria: use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella. Anal. Chem. 68 23 (1996) 4153-4159
    • (1996) Anal. Chem. , vol.68 , Issue.23 , pp. 4153-4159
    • Brewster, J.D.1    Gehring, A.G.2    Mazenko, R.S.3    Van Houten, L.J.4    Crawford, C.J.5
  • 5
    • 15944423985 scopus 로고    scopus 로고
    • Outbreaks of Salmonella infections associated with eating roma tomatoes-United States and Canada, 2004
    • CDC. Outbreaks of Salmonella infections associated with eating roma tomatoes-United States and Canada, 2004. MMWR 54 13 (2005) 325-328
    • (2005) MMWR , vol.54 , Issue.13 , pp. 325-328
    • CDC1
  • 6
    • 33644762769 scopus 로고    scopus 로고
    • Multistate outbreak of Salmonella typhimurium infections associated with eating ground beef - United States, 2004
    • CDC. Multistate outbreak of Salmonella typhimurium infections associated with eating ground beef - United States, 2004. MMWR 55 7 (2006) 180-182
    • (2006) MMWR , vol.55 , Issue.7 , pp. 180-182
    • CDC1
  • 7
    • 0344305786 scopus 로고    scopus 로고
    • Magnetoelastic immunosensors: amplified mass immunosorbent assay for detection of Escherichia coli O157:H7
    • Chuanmin Ruan K.Z., Varghese O.K., and Grimes C.A. Magnetoelastic immunosensors: amplified mass immunosorbent assay for detection of Escherichia coli O157:H7. Anal. Chem. 75 (2003) 6494-6498
    • (2003) Anal. Chem. , vol.75 , pp. 6494-6498
    • Chuanmin Ruan, K.Z.1    Varghese, O.K.2    Grimes, C.A.3
  • 8
    • 33846349888 scopus 로고    scopus 로고
    • A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium
    • Guntupalli R., Hu J., Lakshmanan R.S., Huang T.S., Barbaree J.M., and Chin B.A. A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium. Biosens. Bioelectron. 22 (2007) 1474-1479
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 1474-1479
    • Guntupalli, R.1    Hu, J.2    Lakshmanan, R.S.3    Huang, T.S.4    Barbaree, J.M.5    Chin, B.A.6
  • 9
    • 34250731690 scopus 로고    scopus 로고
    • Honeywell (September, 2006). Magnetic Alloy 2826MB; Technical Bulletin, http://metglas.com/products/page5_1_2_7.htm.
  • 10
    • 0029287193 scopus 로고
    • Salmonella contamination in commercial eggs and an egg production facility
    • Jones F., Rives D., and Carey. Salmonella contamination in commercial eggs and an egg production facility. J. Poult. Sci. 74 (1995) 753-757
    • (1995) J. Poult. Sci. , vol.74 , pp. 753-757
    • Jones, F.1    Rives, D.2    Carey3
  • 11
    • 0034856782 scopus 로고    scopus 로고
    • Precautions against biological and chemical terrorism directed at food and water supplies
    • Khan A.S., Swerdlow D.L., and Juranek D.D. Precautions against biological and chemical terrorism directed at food and water supplies. Public Health Rep. 116 (2001) 3-14
    • (2001) Public Health Rep. , vol.116 , pp. 3-14
    • Khan, A.S.1    Swerdlow, D.L.2    Juranek, D.D.3
  • 12
    • 0035122155 scopus 로고    scopus 로고
    • Comparison of selective procedures for isolation and enumeration of Legionella species from hot water systems
    • Leoni E., and Legnani P.P. Comparison of selective procedures for isolation and enumeration of Legionella species from hot water systems. J. Appl. Microbiol. 90 1 (2001) 27-33
    • (2001) J. Appl. Microbiol. , vol.90 , Issue.1 , pp. 27-33
    • Leoni, E.1    Legnani, P.P.2
  • 13
    • 0043028272 scopus 로고    scopus 로고
    • Evaluation of a real-time PCR hybridization assay for rapid detection of Legionella pneumophila in hospital and environmental water samples
    • Levi K., Smedley J., and Towner K.J. Evaluation of a real-time PCR hybridization assay for rapid detection of Legionella pneumophila in hospital and environmental water samples. Clin. Microbiol. Infect. 9 7 (2003) 754-758
    • (2003) Clin. Microbiol. Infect. , vol.9 , Issue.7 , pp. 754-758
    • Levi, K.1    Smedley, J.2    Towner, K.J.3
  • 14
    • 0037403563 scopus 로고    scopus 로고
    • A conductometric biosensor for biosecurity
    • Muhammad-Tahir Z., and Alocilja E.C. A conductometric biosensor for biosecurity. Biosens. Bioelectron. 18 5-6 (2003) 813-819
    • (2003) Biosens. Bioelectron. , vol.18 , Issue.5-6 , pp. 813-819
    • Muhammad-Tahir, Z.1    Alocilja, E.C.2
  • 15
    • 2942550643 scopus 로고    scopus 로고
    • Surface plasmon resonance immunosensor using self-assembled protein G for the detection of Salmonella paratyphi
    • Oh B.K., Lee W., Kim Y.-K., Lee W.H., and Choi J.W. Surface plasmon resonance immunosensor using self-assembled protein G for the detection of Salmonella paratyphi. J. Biotechnol. 111 1 (2004) 1-8
    • (2004) J. Biotechnol. , vol.111 , Issue.1 , pp. 1-8
    • Oh, B.K.1    Lee, W.2    Kim, Y.-K.3    Lee, W.H.4    Choi, J.W.5
  • 18
    • 0037401049 scopus 로고    scopus 로고
    • Phage display for detection of biological threat agents
    • Petrenko V.A., and Vodyanoy V.J. Phage display for detection of biological threat agents. J. Microbiol. Methods 53 (2003) 253
    • (2003) J. Microbiol. Methods , vol.53 , pp. 253
    • Petrenko, V.A.1    Vodyanoy, V.J.2
  • 21
    • 0033622670 scopus 로고    scopus 로고
    • A remote query magnetostrictive viscosity sensor
    • Stoyanov P.G., and Grimes C.A. A remote query magnetostrictive viscosity sensor. Sens. Actuators, A, Phys. 80 (2000) 8-14
    • (2000) Sens. Actuators, A, Phys. , vol.80 , pp. 8-14
    • Stoyanov, P.G.1    Grimes, C.A.2
  • 22
    • 18544388206 scopus 로고    scopus 로고
    • Comparison of E. coli O157:H7 preparation methods used for detection with surface plasmon resonance sensor
    • Taylor A.D., Yu Q., Chen S., Homola J., and Jiang S. Comparison of E. coli O157:H7 preparation methods used for detection with surface plasmon resonance sensor. Sens. Actuators, B, Chem. 107 1 (2005) 202-208
    • (2005) Sens. Actuators, B, Chem. , vol.107 , Issue.1 , pp. 202-208
    • Taylor, A.D.1    Yu, Q.2    Chen, S.3    Homola, J.4    Jiang, S.5
  • 23
    • 34248157715 scopus 로고    scopus 로고
    • Antibody immobilization on waveguides using a flow-through system shows improved Listeria monocytogenes detection in an automated fiber optic biosensor: RAPTOR(tm)
    • Viswaprakash Nanduri, G.K., Morgan M.T., Ess D., Hahm B.-K., Kothapalli A., Valadez A., Geng T., and Bhunia A.K. Antibody immobilization on waveguides using a flow-through system shows improved Listeria monocytogenes detection in an automated fiber optic biosensor: RAPTOR(tm). Sensors 6 (2006) 808-822
    • (2006) Sensors , vol.6 , pp. 808-822
    • Viswaprakash Nanduri, G.K.1    Morgan, M.T.2    Ess, D.3    Hahm, B.-K.4    Kothapalli, A.5    Valadez, A.6    Geng, T.7    Bhunia, A.K.8
  • 25
    • 15444356204 scopus 로고    scopus 로고
    • Piezoelectric biosensor for detection of Salmonella typhimurium
    • Ye L., Letcher S.V., and Rand A.G. Piezoelectric biosensor for detection of Salmonella typhimurium. J. Food Sci. 62 (1997) 1067-1086
    • (1997) J. Food Sci. , vol.62 , pp. 1067-1086
    • Ye, L.1    Letcher, S.V.2    Rand, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.