메뉴 건너뛰기




Volumn , Issue , 2006, Pages 179-182

Broadband air-core brooks-coil induction magnetometer

Author keywords

Biomagnetic measurements; Broadband; Brooks coil; Induction magnetometer

Indexed keywords

BIOMAGNETIC MEASUREMENTS; FREQUENCY COMPENSATION; INDUCTION MAGNETOMETERS; NOISE FLOOR LEVELS;

EID: 34250745900     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SICE.2006.315397     Document Type: Conference Paper
Times cited : (6)

References (9)
  • 1
    • 0019066684 scopus 로고
    • A portable low noise low frequency three-axis search coil magnetometer
    • S. A. Macintyre, "A portable low noise low frequency three-axis search coil magnetometer", IEEE Trans. Magn., 16, pp.761-763 (1980).
    • (1980) IEEE Trans. Magn , vol.16 , pp. 761-763
    • Macintyre, S.A.1
  • 2
    • 0020197283 scopus 로고
    • Air-core induction-coil magnetometer design
    • K. P. Estola, and J. Malmivuo, "Air-core induction-coil magnetometer design", J. Phys. E: Sci. Instrum. 15, pp. 1110-1113 (1982).
    • (1982) J. Phys. E: Sci. Instrum , vol.15 , pp. 1110-1113
    • Estola, K.P.1    Malmivuo, J.2
  • 4
    • 0042878579 scopus 로고    scopus 로고
    • Compact room-temperature induction magnetometer with superconducting quantum interference device level field sensitivity
    • R. J. Prance, T. D. Clark, H. Prance, "Compact room-temperature induction magnetometer with superconducting quantum interference device level field sensitivity", Rev. Sci. Instrum. 74, pp. 3735-3739 (2003).
    • (2003) Rev. Sci. Instrum , vol.74 , pp. 3735-3739
    • Prance, R.J.1    Clark, T.D.2    Prance, H.3
  • 5
    • 33645230570 scopus 로고    scopus 로고
    • R. Sklyar, Superconducting induction magneto meter, IEEE Sensors J., 6, no. 2, pp. 35 7-364 (2006).
    • R. Sklyar, "Superconducting induction magneto meter", IEEE Sensors J., vol. 6, no. 2, pp. 35 7-364 (2006).
  • 6
    • 34250773857 scopus 로고    scopus 로고
    • Optimal design of an air-core indu ction magnetometer for detecting low-frequency fields of less than 1 pT
    • K. Tashiro, "Optimal design of an air-core indu ction magnetometer for detecting low-frequency fields of less than 1 pT", J. Magn. Soc. Jpn., 30, pp. 439-442 (2006).
    • (2006) J. Magn. Soc. Jpn , vol.30 , pp. 439-442
    • Tashiro, K.1
  • 8
    • 0020783454 scopus 로고
    • Uniform magnetic field produced by three, four, and five square coils
    • R. Merritt, C. Purcell, G. Stroink, "Uniform magnetic field produced by three, four, and five square coils", Rev. Sci. Instrum, vol. 54, pp. 879-882 (1983).
    • (1983) Rev. Sci. Instrum , vol.54 , pp. 879-882
    • Merritt, R.1    Purcell, C.2    Stroink, G.3
  • 9
    • 0037639104 scopus 로고    scopus 로고
    • Spontaneous magnetoence phalography alpha rhythm measurement in a cylindrical magnetic shield employing magnetic shaking
    • K. Tashiro, K. Nagashima, A. Sumida, T. Fukunaga, and I. Sasada, "Spontaneous magnetoence phalography alpha rhythm measurement in a cylindrical magnetic shield employing magnetic shaking", J. Appl. Phys., 93, pp. 6733-6735 (2003).
    • (2003) J. Appl. Phys , vol.93 , pp. 6733-6735
    • Tashiro, K.1    Nagashima, K.2    Sumida, A.3    Fukunaga, T.4    Sasada, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.