메뉴 건너뛰기




Volumn 58, Issue 3, 2007, Pages 303-308

Comparison of Doppler and oscillometric ankle blood pressure measurement in patients with angiographically documented lower extremity arterial occlusive disease

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; ANGIOGRAPHY; ANKLE BRACHIAL INDEX; ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC VALUE; DOPPLER FLOWMETRY; FEMALE; HUMAN; INTERMETHOD COMPARISON; LEG ARTERY; LEG ISCHEMIA; MAJOR CLINICAL STUDY; MALE; OSCILLOMETRY; PERIPHERAL OCCLUSIVE ARTERY DISEASE; PROSPECTIVE STUDY; RELIABILITY;

EID: 34250736323     PISSN: 00033197     EISSN: None     Source Type: Journal    
DOI: 10.1177/0003319707302673     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 0015518781 scopus 로고
    • Response of ankle systolic pressure to leg exercise in mild or questionable arterial disease
    • Carter SA: Response of ankle systolic pressure to leg exercise in mild or questionable arterial disease. N Engl J Med 287: 578-582, 1972.
    • (1972) N Engl J Med , vol.287 , pp. 578-582
    • Carter, S.A.1
  • 2
    • 0029861972 scopus 로고    scopus 로고
    • Variation in measurement of ankle-brachial pressure index in routine clinical practice
    • Fisher CM, Burnett A., Makeham V.,, et al. Variation in measurement of ankle-brachial pressure index in routine clinical practice. J Vasc Surg 24: 871-875, 1996.
    • (1996) J Vasc Surg , vol.24 , pp. 871-875
    • Fisher, C.M.1    Burnett, A.2    Makeham, V.3
  • 3
    • 0001517263 scopus 로고
    • Un nuovo sfigmomanometro
    • Riva - 1001-1017
    • Riva - Rocci S.: Un nuovo sfigmomanometro. Gazzetta Med Torino 47: 981-996, 1001-1017, 1896.
    • (1896) Gazzetta Med Torino , Issue.47 , pp. 981-996
    • Rocci, S.1
  • 4
    • 0015071861 scopus 로고
    • Digital systolic pressures in the lower limb in arterial disease
    • Carter SA, Lezack JD: Digital systolic pressures in the lower limb in arterial disease. Circulation 43: 905-914, 1971.
    • (1971) Circulation , vol.43 , pp. 905-914
    • Carter, S.A.1    Lezack, J.D.2
  • 5
    • 0015318715 scopus 로고
    • Digital blood pressure measurement in occlusive arterial disease, strain gauge compared to Xe-133
    • Lassen NA, Tvedegaard E., Jeppesen FI,, et al. Digital blood pressure measurement in occlusive arterial disease, strain gauge compared to Xe-133. Angiology 8: 211-217, 1972.
    • (1972) Angiology , vol.8 , pp. 211-217
    • Lassen, N.A.1    Tvedegaard, E.2    Jeppesen, F.I.3
  • 6
    • 0016493681 scopus 로고
    • Assessment of arterial obstruction in vessels supplying the fingers by measurement of local blood pressures and the skin temperature response test-correlation with angiographic evidence
    • Downs AR, Gaskell P., Morrow I.,, et al. Assessment of arterial obstruction in vessels supplying the fingers by measurement of local blood pressures and the skin temperature response test-correlation with angiographic evidence. Surgery 77: 530-539, 1975.
    • (1975) Surgery , vol.77 , pp. 530-539
    • Downs, A.R.1    Gaskell, P.2    Morrow, I.3
  • 7
    • 84894896082 scopus 로고
    • Indirect measurement of human blood pressure by the Doppler ultrasonic technique
    • Kemmerer WT, Ware RW, Stegall HF,, et al. Indirect measurement of human blood pressure by the Doppler ultrasonic technique. Surg For 13: 163-165, 1967.
    • (1967) Surg for , vol.13 , pp. 163-165
    • Kemmerer, W.T.1    Ware, R.W.2    Stegall, H.F.3
  • 8
    • 0023893146 scopus 로고
    • Variability of ankle and brachial systolic pressures in the measurement of atherosclerotic peripheral arterial disease
    • Fowkes FG, Housley E., Macintyre CC,, et al. Variability of ankle and brachial systolic pressures in the measurement of atherosclerotic peripheral arterial disease. J Epidemiol Commun Health 42: 128-133, 1988.
    • (1988) J Epidemiol Commun Health , vol.42 , pp. 128-133
    • Fowkes, F.G.1    Housley, E.2    MacIntyre, C.C.3
  • 9
    • 0030026796 scopus 로고    scopus 로고
    • The correlation of ankle oscillometric blood pressure and segmental pulse volumes to Doppler systolic pressures in arterial occlusive disease
    • Lee BY, Campbell JS, Berkowitz P.: The correlation of ankle oscillometric blood pressure and segmental pulse volumes to Doppler systolic pressures in arterial occlusive disease. J Vasc Surg 23: 116-122, 1996.
    • (1996) J Vasc Surg , vol.23 , pp. 116-122
    • Lee, B.Y.1    Campbell, J.S.2    Berkowitz, P.3
  • 10
    • 0028345786 scopus 로고
    • Reliability of ankle:brachial pressure index measurement by junior doctors
    • Ray SA, Srodon PD, Taylor RS,, et al. Reliability of ankle:brachial pressure index measurement by junior doctors. Br J Surg 81: 188-190, 1994.
    • (1994) Br J Surg , vol.81 , pp. 188-190
    • Ray, S.A.1    Srodon, P.D.2    Taylor, R.S.3
  • 11
    • 0033166921 scopus 로고    scopus 로고
    • The influence of experience on the reproducibility of the ankle-brachial systolic pressure ratio in peripheral arterial occlusive disease
    • Kaiser V., Kester AD, Stoffers Hejh,, et al. The influence of experience on the reproducibility of the ankle-brachial systolic pressure ratio in peripheral arterial occlusive disease. Eur J Vasc Endovasc Surg 18: 25-29, 1999.
    • (1999) Eur J Vasc Endovasc Surg , vol.18 , pp. 25-29
    • Kaiser, V.1    Kester, A.D.2    Hejh, S.3
  • 12
    • 0021279968 scopus 로고
    • An electronic instrument for indirect blood-pressure measurements
    • Hoyt BK, Wolf HK: An electronic instrument for indirect blood-pressure measurements. Lancet 2: 552-553, 1984.
    • (1984) Lancet , vol.2 , pp. 552-553
    • Hoyt, B.K.1    Wolf, H.K.2
  • 13
    • 0031723204 scopus 로고    scopus 로고
    • Comparison of three blood pressure methods used for determining ankle/brachial index in patients with intermittent claudication
    • Gardner AW,, et al. Comparison of three blood pressure methods used for determining ankle/brachial index in patients with intermittent claudication. Angiology 49: 723-728, 1998.
    • (1998) Angiology , vol.49 , pp. 723-728
    • Gardner, A.W.1
  • 14
    • 0035991085 scopus 로고    scopus 로고
    • A simple oscillometric technique for determining new indices of arterial distensibility
    • Kubo T., Miyata M., Minagoe S.,, et al. A simple oscillometric technique for determining new indices of arterial distensibility. Hypertens Res 25: 351-358, 2002.
    • (2002) Hypertens Res , vol.25 , pp. 351-358
    • Kubo, T.1    Miyata, M.2    Minagoe, S.3
  • 15
    • 1542708360 scopus 로고    scopus 로고
    • Brachial-ankle pulse wave velocity measured automatically by oscillometric method is elevated in diabetic patients with incipient nephropathy
    • Yokoyama H., Hirasawa K., Aoki T.,, et al. Brachial-ankle pulse wave velocity measured automatically by oscillometric method is elevated in diabetic patients with incipient nephropathy. Diabet Med 20: 942-945, 2003.
    • (2003) Diabet Med , vol.20 , pp. 942-945
    • Yokoyama, H.1    Hirasawa, K.2    Aoki, T.3
  • 16
    • 0037835946 scopus 로고    scopus 로고
    • Ankle-brachial blood pressure index predicts all-cause and cardiovascular mortality in hemodialysis patients
    • Ono K., Tsuchida A., Kawai H.,, et al. Ankle-brachial blood pressure index predicts all-cause and cardiovascular mortality in hemodialysis patients. J Am Soc Nephrol 14: 1591-1598, 2003.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 1591-1598
    • Ono, K.1    Tsuchida, A.2    Kawai, H.3
  • 17
    • 1442338279 scopus 로고    scopus 로고
    • Childhood blood pressure as a predictor of arterial stiffness in young adults: The Bogalusa heart study
    • Li S., Chen W., Srinivasan SR,, et al. Childhood blood pressure as a predictor of arterial stiffness in young adults: The Bogalusa heart study. Hypertension 43: 541-546, 2004.
    • (2004) Hypertension , vol.43 , pp. 541-546
    • Li, S.1    Chen, W.2    Srinivasan, S.R.3
  • 18
    • 3142657232 scopus 로고    scopus 로고
    • Ankle-brachial pressure index measured using an automated oscillometric method as a predictor of the severity of coronary atherosclerosis in patients with coronary artery disease. Kaohsiung
    • Su HM, Voon WC, Lin TH,, et al. Ankle-brachial pressure index measured using an automated oscillometric method as a predictor of the severity of coronary atherosclerosis in patients with coronary artery disease. Kaohsiung J Med Sci 20: 268-272, 2004.
    • (2004) J Med Sci , vol.20 , pp. 268-272
    • Su, H.M.1    Voon, W.C.2    Th, L.3
  • 19
    • 0023443633 scopus 로고
    • Ankle blood pressure measured by automatic oscillotonometry: A comparison with Doppler pressure measurements
    • Adiseshiah M., Cross FW, Belshman PA: Ankle blood pressure measured by automatic oscillotonometry: A comparison with Doppler pressure measurements. Ann R Coll Surg Engl 69: 271-273, 1987.
    • (1987) Ann R Coll Surg Engl , vol.69 , pp. 271-273
    • Adiseshiah, M.1    Cross, F.W.2    Belshman, P.A.3
  • 20
    • 0026642464 scopus 로고
    • Measuring ankle systolic blood pressure: Validation of the Dinamap 1846 SX
    • Mundt KA, Chambless LE, Burnham CB,, et al. Measuring ankle systolic blood pressure: Validation of the Dinamap 1846 SX. Angiology 43: 555-556, 1992.
    • (1992) Angiology , vol.43 , pp. 555-556
    • Mundt, K.A.1    Le, C.2    Burnham, C.B.3
  • 21
    • 0030909842 scopus 로고    scopus 로고
    • Automatic postoperative monitoring of infrainguinal bypass procedures
    • Blebea J., Ali MK, Love M.,, et al. Automatic postoperative monitoring of infrainguinal bypass procedures. Arch Surg 132: 286-291, 1997.
    • (1997) Arch Surg , vol.132 , pp. 286-291
    • Blebea, J.1    Ali, M.K.2    Love, M.3
  • 22
    • 0035043365 scopus 로고    scopus 로고
    • Is oscillometric ankle pressure reliable in leg vascular disease?
    • Jonsson B., Lindberg LG, Skau T.,, et al. Is oscillometric ankle pressure reliable in leg vascular disease? Clin Physiol 21: 155-163, 2001.
    • (2001) Clin Physiol , vol.21 , pp. 155-163
    • Jonsson, B.1    Lindberg, L.G.2    Skau, T.3
  • 23
    • 0037366488 scopus 로고    scopus 로고
    • Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique
    • Ramanathan A., Conaghan PJ, Jenkinson AD,, et al. Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique. Aust NZ J Surg 73: 105-108, 2003.
    • (2003) Aust NZ J Surg , vol.73 , pp. 105-108
    • Ramanathan, A.1    Conaghan, P.J.2    Jenkinson, A.D.3
  • 24
    • 0020962159 scopus 로고
    • What is Buerger's disease?
    • Shionoya S.: What is Buerger's disease? World J Surg 7: 544-551, 1983.
    • (1983) World J Surg , vol.7 , pp. 544-551
    • Shionoya, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.