메뉴 건너뛰기




Volumn 42, Issue 7, 2007, Pages 536-541

Evaluation of coronary stents and stenoses at different heart rates with dual source spiral CT (DSCT)

Author keywords

Angiography; Coronary CTA; CT; Dual source; MDCT; Stenosis; Stent

Indexed keywords

ARTICLE; ARTIFACT; BLOOD VESSEL DIAMETER; CORONARY ARTERY OBSTRUCTION; CORONARY STENT; HEART MOVEMENT; HEART RATE; IMAGE ANALYSIS; IMAGE QUALITY; MEASUREMENT ERROR; PRIORITY JOURNAL; REGRESSION ANALYSIS; ROBOTICS; SIMULATION; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 34250734125     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/RLI.0b013e318041f674     Document Type: Article
Times cited : (36)

References (23)
  • 1
    • 10344230948 scopus 로고    scopus 로고
    • Performance evaluation of a 64-slice CT system with z-flying focal spot
    • Flohr T, Stierstorfer K, Raupach R, et al. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo. 2004;176:1803-1810.
    • (2004) Rofo , vol.176 , pp. 1803-1810
    • Flohr, T.1    Stierstorfer, K.2    Raupach, R.3
  • 2
    • 33745015635 scopus 로고    scopus 로고
    • Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed
    • Wintersperger BJ, Nikolaou K, von Ziegler F, et al. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol. 2006;41:436-442.
    • (2006) Invest Radiol , vol.41 , pp. 436-442
    • Wintersperger, B.J.1    Nikolaou, K.2    von Ziegler, F.3
  • 3
    • 10744227532 scopus 로고    scopus 로고
    • Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography
    • Achenbach S, Ropers D, Hoffmann U, et al. Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography. J Am Coll Cardiol. 2004;43:842-847.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 842-847
    • Achenbach, S.1    Ropers, D.2    Hoffmann, U.3
  • 4
    • 7544220286 scopus 로고    scopus 로고
    • Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: Patient-versus segment-based analysis
    • Hoffmann U, Moselewski F, Cury RC, et al. Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation. 2004;110:2638-2643.
    • (2004) Circulation , vol.110 , pp. 2638-2643
    • Hoffmann, U.1    Moselewski, F.2    Cury, R.C.3
  • 5
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: A comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber AW, Knez A, von Ziegler F, et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol. 2005;46:147-154.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    von Ziegler, F.3
  • 6
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff GL, Gallagher MJ, O'Neill WW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005;46:552-557.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3
  • 7
    • 0037254248 scopus 로고    scopus 로고
    • Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    • Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology. 2003;226:145-152.
    • (2003) Radiology , vol.226 , pp. 145-152
    • Hunold, P.1    Vogt, F.M.2    Schmermund, A.3
  • 8
    • 22844451841 scopus 로고    scopus 로고
    • Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation
    • Gerber TC, Stratmann BP, Kuzo RS, et al. Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation. Invest Radiol. 2005;40:556-563.
    • (2005) Invest Radiol , vol.40 , pp. 556-563
    • Gerber, T.C.1    Stratmann, B.P.2    Kuzo, R.S.3
  • 9
    • 33749853083 scopus 로고    scopus 로고
    • Measurement of coronary artery bifurcation angles by multidetector computed tomography
    • Pflederer T, Ludwig J, Ropers D, et al. Measurement of coronary artery bifurcation angles by multidetector computed tomography. Invest Radiol. 2006;41:793-798.
    • (2006) Invest Radiol , vol.41 , pp. 793-798
    • Pflederer, T.1    Ludwig, J.2    Ropers, D.3
  • 10
    • 0347419480 scopus 로고    scopus 로고
    • Coronary artery stents in multislice computed tomography: In vitro artifact evaluation
    • Mahnken AH, Buecker A, Wildberger JE, et al. Coronary artery stents in multislice computed tomography: in vitro artifact evaluation. Invest Radiol. 2004;39:27-33.
    • (2004) Invest Radiol , vol.39 , pp. 27-33
    • Mahnken, A.H.1    Buecker, A.2    Wildberger, J.E.3
  • 11
    • 33644909898 scopus 로고    scopus 로고
    • 64-slice multidetector coronary CT angiography: In vitro evaluation of 68 different stents
    • Maintz D, Seifarth H, Raupach R, et al. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol. 2006;16:818-826.
    • (2006) Eur Radiol , vol.16 , pp. 818-826
    • Maintz, D.1    Seifarth, H.2    Raupach, R.3
  • 12
    • 33645064323 scopus 로고    scopus 로고
    • 64- versus 16-slice CT angiography for coronary artery stent assessment: In vitro experience
    • Seifarth H, Ozgun M, Raupach R, et al. 64- versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience. Invest Radiol. 2006;41:22-27.
    • (2006) Invest Radiol , vol.41 , pp. 22-27
    • Seifarth, H.1    Ozgun, M.2    Raupach, R.3
  • 13
    • 27744544089 scopus 로고    scopus 로고
    • Evaluation of coronary stents in vitro with CT angiography: Effect of stent diameter, convolution kernel, and vessel orientation to the z-axis
    • Suzuki S, Furui S, Kaminaga T, et al. Evaluation of coronary stents in vitro with CT angiography: effect of stent diameter, convolution kernel, and vessel orientation to the z-axis. Circ J. 2005;69:1124-1131.
    • (2005) Circ J , vol.69 , pp. 1124-1131
    • Suzuki, S.1    Furui, S.2    Kaminaga, T.3
  • 14
    • 11144340393 scopus 로고    scopus 로고
    • Flat-panel detector computed tomography for the assessment of coronary artery stents: Phantom study in comparison with 16-slice spiral computed tomography
    • Mahnken AH, Seyfarth T, Flohr T, et al. Flat-panel detector computed tomography for the assessment of coronary artery stents: phantom study in comparison with 16-slice spiral computed tomography. Invest Radiol. 2005;40:8-13.
    • (2005) Invest Radiol , vol.40 , pp. 8-13
    • Mahnken, A.H.1    Seyfarth, T.2    Flohr, T.3
  • 15
    • 33744739422 scopus 로고    scopus 로고
    • Multidetector CT for visualization of coronary stents
    • Pugliese F, Cademartiri F, van Mieghem C, et al. Multidetector CT for visualization of coronary stents. Radiographics. 2006;26:887-904.
    • (2006) Radiographics , vol.26 , pp. 887-904
    • Pugliese, F.1    Cademartiri, F.2    van Mieghem, C.3
  • 16
    • 0033876932 scopus 로고    scopus 로고
    • In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    • Achenbach S, Ropers D, Holle J, et al. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology. 2000;216:457-463.
    • (2000) Radiology , vol.216 , pp. 457-463
    • Achenbach, S.1    Ropers, D.2    Holle, J.3
  • 17
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256-268.
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 18
    • 4644360295 scopus 로고    scopus 로고
    • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: Initial experience
    • Hong C, Chrysant GS, Woodard PK, et al. Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience. Radiology. 2004;233:286-291.
    • (2004) Radiology , vol.233 , pp. 286-291
    • Hong, C.1    Chrysant, G.S.2    Woodard, P.K.3
  • 19
    • 33746663053 scopus 로고    scopus 로고
    • Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: A phantom study
    • Mahnken AH, Hohl C, Suess C, et al. Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study. Invest Radiol. 2006;41:429-435.
    • (2006) Invest Radiol , vol.41 , pp. 429-435
    • Mahnken, A.H.1    Hohl, C.2    Suess, C.3
  • 20
    • 0035176903 scopus 로고    scopus 로고
    • Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    • Flohr T, Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr. 2001;25:907-923.
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 907-923
    • Flohr, T.1    Ohnesorge, B.2
  • 21
    • 0030989450 scopus 로고    scopus 로고
    • Accuracy and precision of CT angiography in a model of carotid artery bifurcation stenosis
    • Dix JE, Evans AJ, Kallmes DF, et al. Accuracy and precision of CT angiography in a model of carotid artery bifurcation stenosis. AJNR Am J Neuroradiol. 1997;18:409-415.
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 409-415
    • Dix, J.E.1    Evans, A.J.2    Kallmes, D.F.3
  • 22
    • 32844464236 scopus 로고    scopus 로고
    • Contrast-enhanced coronary artery visualization by dual-source computed tomography - initial experience
    • Achenbach S, Ropers D, Kuettner A, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography - initial experience. Eur J Radiol. 2006;57:331-335.
    • (2006) Eur J Radiol , vol.57 , pp. 331-335
    • Achenbach, S.1    Ropers, D.2    Kuettner, A.3
  • 23
    • 33745024717 scopus 로고    scopus 로고
    • Dual-source CT cardiac imaging: Initial experience
    • Johnson TR, Nikolaou K, Wintersperger BJ, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol. 2006;16:1409-1415.
    • (2006) Eur Radiol , vol.16 , pp. 1409-1415
    • Johnson, T.R.1    Nikolaou, K.2    Wintersperger, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.