-
1
-
-
0019031727
-
SPECT: Single photon emission computed tomography
-
R. J. Jaszczak, R. E. Coleman, and C. B. Lim, "SPECT: Single photon emission computed tomography," IEEE Trans. Nucl. Sci., vol. NS-27, no. 3, pp. 1137-1153, 1980.
-
(1980)
IEEE Trans. Nucl. Sci
, vol.NS-27
, Issue.3
, pp. 1137-1153
-
-
Jaszczak, R.J.1
Coleman, R.E.2
Lim, C.B.3
-
2
-
-
0017928606
-
Single photon emission computed tomography using multi-slice fan beam collimators
-
R. J. Jaszczak, L. T. Chang, and P. H. Murphy, "Single photon emission computed tomography using multi-slice fan beam collimators," IEEE Trans. Nucl. Sci., vol. NS-26, pp. 610-618, 1979.
-
(1979)
IEEE Trans. Nucl. Sci
, vol.NS-26
, pp. 610-618
-
-
Jaszczak, R.J.1
Chang, L.T.2
Murphy, P.H.3
-
3
-
-
0022893713
-
Design and clinical utility of a fan beam collimator for SPECT imaging of the head
-
B. M. W. Tsui et al., "Design and clinical utility of a fan beam collimator for SPECT imaging of the head.," J. Nucl. Med., vol. 27, pp. 810-819, 1986.
-
(1986)
J. Nucl. Med
, vol.27
, pp. 810-819
-
-
Tsui, B.M.W.1
-
4
-
-
0022525205
-
Cone beam collimation for single photon emission computed tomography: Analysis, simulation and image reconstruction using filtered backprojection
-
R. J. Jaszczak, C. E. Floyd, S. H. Manglos, K. L. Greer, and R. E. Coleman, "Cone beam collimation for single photon emission computed tomography: Analysis, simulation and image reconstruction using filtered backprojection," Med. Phys., vol. 13, no. 4, pp. 484-489, 1986.
-
(1986)
Med. Phys
, vol.13
, Issue.4
, pp. 484-489
-
-
Jaszczak, R.J.1
Floyd, C.E.2
Manglos, S.H.3
Greer, K.L.4
Coleman, R.E.5
-
5
-
-
0023677772
-
SPECT using a specially designed cone beam collimator
-
R. J. Jaszczak, K. L. Greer, and R. E. Coleman, "SPECT using a specially designed cone beam collimator," J. Nucl. Med., vol. 29, pp. 1398-1405, 1988.
-
(1988)
J. Nucl. Med
, vol.29
, pp. 1398-1405
-
-
Jaszczak, R.J.1
Greer, K.L.2
Coleman, R.E.3
-
6
-
-
22544476189
-
Brain SPECT with short focal-length cone-beam collimation
-
M.-A. Park, S. C. Moore, and M. F. Kijewski, "Brain SPECT with short focal-length cone-beam collimation," Med. Phys, vol. 32, no. 7, pp. 2236-2244, 2005.
-
(2005)
Med. Phys
, vol.32
, Issue.7
, pp. 2236-2244
-
-
Park, M.-A.1
Moore, S.C.2
Kijewski, M.F.3
-
7
-
-
0027424848
-
Cone-beam SPECT with a tilted detector
-
P. Grangeat et al., "Cone-beam SPECT with a tilted detector," Comput. Med. Imaging Graph., vol. 17, no. 4/5, pp. 279-287, 1993.
-
(1993)
Comput. Med. Imaging Graph
, vol.17
, Issue.4-5
, pp. 279-287
-
-
Grangeat, P.1
-
8
-
-
34250770275
-
Half-cone beam collimation for triple-camera SPECT systems
-
R. J. Jaszczak, J. Li, H. Wang, S. Jang, and R. E. Coleman, "Half-cone beam collimation for triple-camera SPECT systems," Eur. J. Nucl. Med., vol. 21, no. 10, p. 27, 1994.
-
(1994)
Eur. J. Nucl. Med
, vol.21
, Issue.10
, pp. 27
-
-
Jaszczak, R.J.1
Li, J.2
Wang, H.3
Jang, S.4
Coleman, R.E.5
-
9
-
-
0029995034
-
Half-cone beam collimation for triple-camera SPECT systems
-
J. Li et al., "Half-cone beam collimation for triple-camera SPECT systems," J. Nucl. Med., vol. 37, no. 3, pp. 498-502, 1996.
-
(1996)
J. Nucl. Med
, vol.37
, Issue.3
, pp. 498-502
-
-
Li, J.1
-
10
-
-
7344241431
-
An astigmatic collimator for high sensitivity SPECT of the brain
-
E. G. Hawman and J. Hsieh, "An astigmatic collimator for high sensitivity SPECT of the brain," J. Nucl. Med., vol. 27, p. 930, 1986.
-
(1986)
J. Nucl. Med
, vol.27
, pp. 930
-
-
Hawman, E.G.1
Hsieh, J.2
-
11
-
-
33744651503
-
Clinical evaluation of an astigmatic collimator for high sensitivity SPECT imaging of the brain
-
R. A. Holmes, K. W. Logan, B. E. Hasselquist, E. G. Hawman, and J. Hsieh, "Clinical evaluation of an astigmatic collimator for high sensitivity SPECT imaging of the brain," J. Nucl. Med., vol. 28, no. 4, pp. 576-577, 1987.
-
(1987)
J. Nucl. Med
, vol.28
, Issue.4
, pp. 576-577
-
-
Holmes, R.A.1
Logan, K.W.2
Hasselquist, B.E.3
Hawman, E.G.4
Hsieh, J.5
-
12
-
-
0028700063
-
Accelerated image reconstruction using ordered subsets of projection data
-
H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag, vol. 13, no. 4, pp. 601-609, 1994.
-
(1994)
IEEE Trans. Med. Imag
, vol.13
, Issue.4
, pp. 601-609
-
-
Hudson, H.M.1
Larkin, R.S.2
-
13
-
-
0020764170
-
An inversion formula for cone-beam reconstruction
-
H. K. Tuy, "An inversion formula for cone-beam reconstruction," SIAM J. Appl. Math., vol. 43, no. 3, pp. 546-552, 1983.
-
(1983)
SIAM J. Appl. Math
, vol.43
, Issue.3
, pp. 546-552
-
-
Tuy, H.K.1
-
14
-
-
0002335619
-
Principles and performance of spiral CT
-
W. A. Kalender, L. W. Goldman and J. B. Fowlkes, Eds, College Park, MD: AAPM
-
W. A. Kalender, L. W. Goldman and J. B. Fowlkes, Eds., "Principles and performance of spiral CT," in Medical CT and Ultrasound: Current Technology and Applications. College Park, MD: AAPM, 1995, pp. 379-410.
-
(1995)
Medical CT and Ultrasound: Current Technology and Applications
, pp. 379-410
-
-
-
15
-
-
0142031180
-
Helical pinhole SPECT for small-animal imaging: A method for addressing sampling completeness
-
Oct
-
S. D. Metzler, K. L. Greer, and R. J. Jaszczak, "Helical pinhole SPECT for small-animal imaging: A method for addressing sampling completeness," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1575-1583, Oct. 2003.
-
(2003)
IEEE Trans. Nucl. Sci
, vol.50
, Issue.5
, pp. 1575-1583
-
-
Metzler, S.D.1
Greer, K.L.2
Jaszczak, R.J.3
-
16
-
-
0033345361
-
Helical SPECT using axially truncated data
-
Dec
-
G. L. Zeng and G. T. Gullberg, "Helical SPECT using axially truncated data," IEEE Trans. Nucl. Sci., vol. 46, no. 6, pp. 2111-2118, Dec. 1999.
-
(1999)
IEEE Trans. Nucl. Sci
, vol.46
, Issue.6
, pp. 2111-2118
-
-
Zeng, G.L.1
Gullberg, G.T.2
-
17
-
-
0027647186
-
A reconstruction algorithm for helical cone-beam SPECT
-
Aug
-
Y. Weng, G. L. Zeng, and G. T. Gullberg, "A reconstruction algorithm for helical cone-beam SPECT," IEEE Trans. Nucl. Sci., vol. 40, no. 4, pp. 1092-1101, Aug. 1993.
-
(1993)
IEEE Trans. Nucl. Sci
, vol.40
, Issue.4
, pp. 1092-1101
-
-
Weng, Y.1
Zeng, G.L.2
Gullberg, G.T.3
-
18
-
-
0036464480
-
Cone-beam iterative reconstruction of a segment of a long object
-
Feb
-
G. L. Zeng, G. T. Gullberg, P. E. Christian, and G. Gagnon, "Cone-beam iterative reconstruction of a segment of a long object," IEEE Trans. Nucl. Sci., vol. 49, no. 1, pp. 37-41, Feb. 2002.
-
(2002)
IEEE Trans. Nucl. Sci
, vol.49
, Issue.1
, pp. 37-41
-
-
Zeng, G.L.1
Gullberg, G.T.2
Christian, P.E.3
Gagnon, G.4
-
19
-
-
0022026907
-
Image reconstruction from cone beam projections: Necessary and sufficient conditions and reconstruction methods
-
B. D. Smith, "Image reconstruction from cone beam projections: Necessary and sufficient conditions and reconstruction methods.," IEEE Trans. Med. Imag., vol. MI-4, no. 1, pp. 14-25, 1985.
-
(1985)
IEEE Trans. Med. Imag
, vol.MI-4
, Issue.1
, pp. 14-25
-
-
Smith, B.D.1
-
20
-
-
38649112976
-
Helical path, half-cone-beam acquisition for SPECT brain imaging
-
presented at the, San Diego, CA
-
R. J. Jaszczak et al., "Helical path, half-cone-beam acquisition for SPECT brain imaging," presented at the IEEE Nuclear Science Symp. and Medical Imaging Conf., San Diego, CA, 2006.
-
(2006)
IEEE Nuclear Science Symp. and Medical Imaging Conf
-
-
Jaszczak, R.J.1
-
21
-
-
0025416077
-
3-D phantom to simulate cerebral blood flow and metabolic images for PET
-
Apr
-
E. J. Hoffman, P. D. Cutler, W. M. Digby, and J. C. Mazziotta, "3-D phantom to simulate cerebral blood flow and metabolic images for PET," IEEE Trans. Nucl. Sci., vol. 37, no. 2, pp. 616-620, Apr. 1990.
-
(1990)
IEEE Trans. Nucl. Sci
, vol.37
, Issue.2
, pp. 616-620
-
-
Hoffman, E.J.1
Cutler, P.D.2
Digby, W.M.3
Mazziotta, J.C.4
|