메뉴 건너뛰기




Volumn 31, Issue 7, 2007, Pages 575-580

Changes in vein dynamics ranging from low to high pressure levels as a determinant of the differences in vein adaptation to arterial hemodynamic conditions

Author keywords

Biomechanics; Circumferential stress; Compliance; Veins; Venous grafts; Viscosity; Wall adaptation

Indexed keywords

GRAFTING (CHEMICAL); GRAFTS; PHYSIOLOGY;

EID: 34250707934     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2007.00424.x     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0036239873 scopus 로고    scopus 로고
    • Improving the clinical patency of prosthetic vascular and coronary bypass grafts: The role of seeding and tissue engineering
    • Seifalian AM, Tiwari A, Hamilton G, Salacinski HJ. Improving the clinical patency of prosthetic vascular and coronary bypass grafts: the role of seeding and tissue engineering. Artif Organs 2002 26 : 307 20.
    • (2002) Artif Organs , vol.26 , pp. 307-320
    • Seifalian, A.M.1    Tiwari, A.2    Hamilton, G.3    Salacinski, H.J.4
  • 2
  • 3
    • 33646948575 scopus 로고    scopus 로고
    • The mechanical properties of infrainguinal vascular bypass grafts: Their role in influencing patency
    • Sarkar S, Salacinski HJ, Hamilton G, Seifalian AM. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur J Vasc Endovasc Surg 2006 31 : 627 36.
    • (2006) Eur J Vasc Endovasc Surg , vol.31 , pp. 627-636
    • Sarkar, S.1    Salacinski, H.J.2    Hamilton, G.3    Seifalian, A.M.4
  • 4
    • 0029071540 scopus 로고
    • Mechanical factors associated with the development of intimal and medial thickening in vein grafts subjected to arterial pressure. a model of arteries exposed to hypertension
    • Dobrin PB. Mechanical factors associated with the development of intimal and medial thickening in vein grafts subjected to arterial pressure. A model of arteries exposed to hypertension. Hypertension 1995 26 : 38 43.
    • (1995) Hypertension , vol.26 , pp. 38-43
    • Dobrin, P.B.1
  • 6
    • 23944489864 scopus 로고    scopus 로고
    • Effect of vein graft harvesting on endothelial nitric oxide synthase and nitric oxide production
    • Dashwood MR, Savage K, Dooley A, Shi-Wen X, Abraham DJ, Souza DS. Effect of vein graft harvesting on endothelial nitric oxide synthase and nitric oxide production. Ann Thorac Surg 2005 80 : 939 44.
    • (2005) Ann Thorac Surg , vol.80 , pp. 939-944
    • Dashwood, M.R.1    Savage, K.2    Dooley, A.3    Shi-Wen, X.4    Abraham, D.J.5    Souza, D.S.6
  • 7
    • 0036208590 scopus 로고    scopus 로고
    • Improved patency in vein grafts harvested with surrounding tissue: Results of a randomized study using three harvesting techniques
    • Souza D, Dashwood M, Tsui J, et al. Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques. Ann Thorac Surg 2002 73 : 1189 95.
    • (2002) Ann Thorac Surg , vol.73 , pp. 1189-1195
    • Souza, D.1    Dashwood, M.2    Tsui, J.3
  • 8
    • 33645466457 scopus 로고    scopus 로고
    • Regional differences in vein wall dynamics under arterial hemodynamics conditions: Comparison with arteries
    • Zócalo Y, Pessana F, Bia D, Armentano R. Regional differences in vein wall dynamics under arterial hemodynamics conditions: comparison with arteries. Artif Organs 2006 30 : 265 75.
    • (2006) Artif Organs , vol.30 , pp. 265-275
    • Zócalo, Y.1    Pessana, F.2    Bia, D.3    Armentano, R.4
  • 9
    • 33644981622 scopus 로고    scopus 로고
    • Smart damping modulation of carotid wall energetics in human hypertension: Effects of ACE inhibition
    • Armentano R, Barra J, Bia D, et al. Smart damping modulation of carotid wall energetics in human hypertension: effects of ACE inhibition. Hypertension 2006 87 : 384 290.
    • (2006) Hypertension , vol.87 , pp. 384-290
    • Armentano, R.1    Barra, J.2    Bia, D.3
  • 10
    • 20544446891 scopus 로고    scopus 로고
    • Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia
    • Cabrera E, Bia D, Cassanello G, Zocalo Y, Crawford E, Armentano R. Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia. Artif Organs 2005 29 : 122 30.
    • (2005) Artif Organs , vol.29 , pp. 122-130
    • Cabrera, E.1    Bia, D.2    Cassanello, G.3    Zocalo, Y.4    Crawford, E.5    Armentano, R.6
  • 11
    • 0002393190 scopus 로고
    • Mechanical properties of arteries in vivo
    • Peterson LH, Jensen RE, Parnell J. Mechanical properties of arteries in vivo. Circ Res 1960 8 : 622 39.
    • (1960) Circ Res , vol.8 , pp. 622-639
    • Peterson, L.H.1    Jensen, R.E.2    Parnell, J.3
  • 12
    • 84942737910 scopus 로고
    • Fitting autoregressive models for prediction
    • Akaike H. Fitting autoregressive models for prediction. Ann Inst Stat Math 1969 21 : 243 7.
    • (1969) Ann Inst Stat Math , vol.21 , pp. 243-247
    • Akaike, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.