Volumn 854, Issue 1-2, 2007, Pages 143-151
|
Development and validation of liquid chromatography-tandem mass spectrometric method for simultaneous determination of fosinopril and its active metabolite fosinoprilat in human plasma
|
Author keywords
Fosinopril; Fosinoprilat; Human plasma; Liquid chromatography tandem mass spectrometry; Pharmacokinetics
|
Indexed keywords
DRUG PRODUCTS;
IONIZATION;
LIQUID CHROMATOGRAPHY;
MAMMALS;
MASS SPECTROMETRY;
METABOLITES;
FOSINOPRIL;
FOSINOPRILAT;
HUMAN PLASMA;
TANDEM MASS SPECTROMETRY;
PHARMACOKINETICS;
FOSINOPRIL;
FOSINOPRILAT;
ZALEPLON;
ACCURACY;
ADULT;
ARTICLE;
CALIBRATION;
CONTROLLED STUDY;
DRUG BLOOD LEVEL;
DRUG DETERMINATION;
DRUG ISOLATION;
DRUG METABOLISM;
DRUG QUALITY;
DRUG STABILITY;
ELECTROSPRAY;
FEMALE;
HUMAN;
IONIZATION;
LIQUID CHROMATOGRAPHY;
LIQUID LIQUID EXTRACTION;
MALE;
MAXIMUM PLASMA CONCENTRATION;
NORMAL HUMAN;
PRIORITY JOURNAL;
REPRODUCIBILITY;
REVERSED PHASE LIQUID CHROMATOGRAPHY;
STANDARD;
TANDEM MASS SPECTROMETRY;
TIME TO MAXIMUM PLASMA CONCENTRATION;
VALIDATION PROCESS;
ANGIOTENSIN-CONVERTING ENZYME INHIBITORS;
FOSINOPRIL;
HUMANS;
REFERENCE STANDARDS;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
SPECTROMETRY, MASS, ELECTROSPRAY IONIZATION;
TANDEM MASS SPECTROMETRY;
|
EID: 34250695963
PISSN: 15700232
EISSN: None
Source Type: Journal
DOI: 10.1016/j.jchromb.2007.04.019 Document Type: Article |
Times cited : (10)
|
References (20)
|