-
1
-
-
34250644895
-
-
Japanese source
-
Japanese source
-
-
-
-
2
-
-
27744508263
-
High-field MRI of the central nervous system: Current approaches to clinical and microscopic imaging
-
Sasaki M, Inoue T, Tohyama K, Oikawa H, Ogawa A, et al: High-field MRI of the central nervous system: current approaches to clinical and microscopic imaging. Magn Reson Med Sci 2: 133-139, 2003
-
(2003)
Magn Reson Med Sci
, vol.2
, pp. 133-139
-
-
Sasaki, M.1
Inoue, T.2
Tohyama, K.3
Oikawa, H.4
Ogawa, A.5
-
3
-
-
12344261624
-
Sensitivity encording for diffusion-weighted MR imaging at 3.0T: Intraindividual comparative study
-
Kuhl CK, Gieseke J, von Falkenhausen M, Textor J, Schild HH, et al: Sensitivity encording for diffusion-weighted MR imaging at 3.0T: intraindividual comparative study. Radiology 234: 517-526, 2005
-
(2005)
Radiology
, vol.234
, pp. 517-526
-
-
Kuhl, C.K.1
Gieseke, J.2
von Falkenhausen, M.3
Textor, J.4
Schild, H.H.5
-
4
-
-
1642541669
-
Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of flight MR angiography
-
Gibbs GF, Huston J 3rd, Bernstein MA, Riederer SJ, Brown RD Jr: Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of flight MR angiography. AJNR Am J Neuroradiol 25: 84-87, 2004
-
(2004)
AJNR Am J Neuroradiol
, vol.25
, pp. 84-87
-
-
Gibbs, G.F.1
Huston 3rd, J.2
Bernstein, M.A.3
Riederer, S.J.4
Brown Jr, R.D.5
-
5
-
-
34250635006
-
-
Japanese source
-
Japanese source
-
-
-
-
6
-
-
4243162030
-
-
Haacke EM, Xu Y, Cheng YC, Reichenbach Jr: Susceptibility weighted imaging. Mag Reson Med 52: 612-618, 2004
-
Haacke EM, Xu Y, Cheng YC, Reichenbach Jr: Susceptibility weighted imaging. Mag Reson Med 52: 612-618, 2004
-
-
-
-
7
-
-
34250640615
-
-
Japanese source
-
Japanese source
-
-
-
-
8
-
-
0032753833
-
High-resolution MR venography of cerebral arteriovenous malformations
-
Essig M, Reichenbach JR, Schad LR, Schoenberg SO, Kaiser WA, et al: High-resolution MR venography of cerebral arteriovenous malformations. Magn Reson Imaging 17: 1417-1425, 1999
-
(1999)
Magn Reson Imaging
, vol.17
, pp. 1417-1425
-
-
Essig, M.1
Reichenbach, J.R.2
Schad, L.R.3
Schoenberg, S.O.4
Kaiser, W.A.5
-
9
-
-
0032795041
-
MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesion
-
Lee BC, Vo KD, Kido DK, Mukherjee P, Haack M, et al: MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesion. AJNR Am J Neuroradiol 20: 1239-1243, 1999
-
(1999)
AJNR Am J Neuroradiol
, vol.20
, pp. 1239-1243
-
-
Lee, B.C.1
Vo, K.D.2
Kido, D.K.3
Mukherjee, P.4
Haack, M.5
-
10
-
-
16844368345
-
MR imaging of hyperacute subarachnoid and intraventricluar hemorrhage at 3T: A preliminary report of gradient echo T2*-weighted sequences
-
Sohn CH, Baik SK, Lee HJ, Lee SM, Sevick RJ, et al: MR imaging of hyperacute subarachnoid and intraventricluar hemorrhage at 3T: a preliminary report of gradient echo T2*-weighted sequences. AJNR Am J Neuroradiol 26: 662-665, 2005
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 662-665
-
-
Sohn, C.H.1
Baik, S.K.2
Lee, H.J.3
Lee, S.M.4
Sevick, R.J.5
-
11
-
-
5444237127
-
Comparison of MRI and CT for detection of acute intracerebral hemorrhage
-
Kidwell CS, Chalela JA, Saver JL, Starkman S, Warach S, et al: Comparison of MRI and CT for detection of acute intracerebral hemorrhage. JAMA 292: 1823-1830, 2004
-
(2004)
JAMA
, vol.292
, pp. 1823-1830
-
-
Kidwell, C.S.1
Chalela, J.A.2
Saver, J.L.3
Starkman, S.4
Warach, S.5
-
12
-
-
10744232087
-
Kompetenznetzwerk Schlaganfall B5: Stroke magnetic resonance imaging is accurate in hyperacute intracerebral hemorrhage: A multicenter study on the validity of stroke imaging
-
Fiebach JB, Schellinger PD, Gass A, Kucinski T, Sartor K, et al: Kompetenznetzwerk Schlaganfall B5: Stroke magnetic resonance imaging is accurate in hyperacute intracerebral hemorrhage: A multicenter study on the validity of stroke imaging. Stroke 35: 502-507, 2004
-
(2004)
Stroke
, vol.35
, pp. 502-507
-
-
Fiebach, J.B.1
Schellinger, P.D.2
Gass, A.3
Kucinski, T.4
Sartor, K.5
-
13
-
-
3242773864
-
Contribution of susceptibility-weighted imaging to acute stroke assessment
-
Hermier M, Nighoghossian N: Contribution of susceptibility-weighted imaging to acute stroke assessment. Stroke 35: 1989-1994, 2004
-
(2004)
Stroke
, vol.35
, pp. 1989-1994
-
-
Hermier, M.1
Nighoghossian, N.2
-
14
-
-
34250651209
-
-
Japanese source
-
Japanese source
-
-
-
-
15
-
-
34250671050
-
-
Japanese source
-
Japanese source
-
-
-
-
16
-
-
0242669163
-
Hemorrhagic shearing lesions in children and adolescents with posttraumatic diffuse axonal injury: Improved detention and initial results
-
Tong KA, Ashwal S, Holshouser BA, Shutter LA, Kido DK, et al: Hemorrhagic shearing lesions in children and adolescents with posttraumatic diffuse axonal injury: improved detention and initial results. Radiology 227: 332-339, 2003
-
(2003)
Radiology
, vol.227
, pp. 332-339
-
-
Tong, K.A.1
Ashwal, S.2
Holshouser, B.A.3
Shutter, L.A.4
Kido, D.K.5
-
17
-
-
34250656500
-
-
Japanese source
-
Japanese source
-
-
-
-
18
-
-
34250646949
-
-
Japanese source
-
Japanese source
-
-
-
-
19
-
-
33745896818
-
Neuromelanin magnetic resonance imaging of locus ceruleus and substantia nigra in Parkinson's disease
-
Sasaki M, Shibata E, Tohyama K, Takahashi J, Sakai A, et al: Neuromelanin magnetic resonance imaging of locus ceruleus and substantia nigra in Parkinson's disease. Neuroreport 17: 1215-1218, 2006
-
(2006)
Neuroreport
, vol.17
, pp. 1215-1218
-
-
Sasaki, M.1
Shibata, E.2
Tohyama, K.3
Takahashi, J.4
Sakai, A.5
-
20
-
-
0036155777
-
MR analysis of the substantia innominata in normal aging, Alzheimer disease, and other types of dementia
-
Hanyu H, Asano T, Sakurai H, Tanaka Y, Abe K, et al: MR analysis of the substantia innominata in normal aging, Alzheimer disease, and other types of dementia. AJNR Am J Neuroradiol 23: 27-32, 2002
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, pp. 27-32
-
-
Hanyu, H.1
Asano, T.2
Sakurai, H.3
Tanaka, Y.4
Abe, K.5
-
21
-
-
17744400162
-
Differences in MR features of the substantia innominata between dementia with Lewy bodies and Alzheimer's disease
-
Hanyu H, Tanaka Y, Shimizu S, Sakurai H, Abe K, et al: Differences in MR features of the substantia innominata between dementia with Lewy bodies and Alzheimer's disease. J Neurol 252: 482-484, 2005
-
(2005)
J Neurol
, vol.252
, pp. 482-484
-
-
Hanyu, H.1
Tanaka, Y.2
Shimizu, S.3
Sakurai, H.4
Abe, K.5
-
22
-
-
0037969981
-
Atrophy of the substantia innominata on magnetic resonance imaging predicts response to donepezil treatment in Alzheimer's disease patients
-
Tanaka Y, Hanyu H, Sakurai H, Takasaki M, Abe K: Atrophy of the substantia innominata on magnetic resonance imaging predicts response to donepezil treatment in Alzheimer's disease patients. Dement Geriatr Cogn Disord 16: 119-125, 2003
-
(2003)
Dement Geriatr Cogn Disord
, vol.16
, pp. 119-125
-
-
Tanaka, Y.1
Hanyu, H.2
Sakurai, H.3
Takasaki, M.4
Abe, K.5
-
23
-
-
0025344047
-
Olivopontocerebellar atrophy: MR diagnosis and relationship to multisystem atrophy
-
Savoiardo M, Strada L, Girotti F, Zimmerman RA, Petrillo R, et al: Olivopontocerebellar atrophy: MR diagnosis and relationship to multisystem atrophy. Radiology 174: 693-696, 1990
-
(1990)
Radiology
, vol.174
, pp. 693-696
-
-
Savoiardo, M.1
Strada, L.2
Girotti, F.3
Zimmerman, R.A.4
Petrillo, R.5
-
24
-
-
32944463656
-
Hyperintense putaminal rim sign is not a hallmark of multiple system atrophy at 3T
-
Lee WH, Lee CC, Shyu WC, Chong PN, Lin SZ: Hyperintense putaminal rim sign is not a hallmark of multiple system atrophy at 3T. AJNR Am J Neuroradiol 26: 2238-2242, 2005
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 2238-2242
-
-
Lee, W.H.1
Lee, C.C.2
Shyu, W.C.3
Chong, P.N.4
Lin, S.Z.5
-
25
-
-
34250620015
-
Hyperintense putaminal rim at 3.0T reflects less ferritin deposits in the lateral marginal area of the putamen
-
in press
-
Fujii S, Matsusue E, Kinoshita T, Sugihara S, Ogawa T, et al: Hyperintense putaminal rim at 3.0T reflects less ferritin deposits in the lateral marginal area of the putamen. AJNR Am J Neuroradiol, in press.
-
AJNR Am J Neuroradiol
-
-
Fujii, S.1
Matsusue, E.2
Kinoshita, T.3
Sugihara, S.4
Ogawa, T.5
-
26
-
-
0036325034
-
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
-
Wang J, Alsop DC, Li L, Listerud J, Detre JA, et al: Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla. Mag Reson Med 48: 242-254, 2002
-
(2002)
Mag Reson Med
, vol.48
, pp. 242-254
-
-
Wang, J.1
Alsop, D.C.2
Li, L.3
Listerud, J.4
Detre, J.A.5
|