-
1
-
-
33746463069
-
Superficial radial nerve injury during standard K-wire fixation of uncomplicated distal radius fractures
-
A cadaver study that correlates nerve injury with percutaneous K-wire fixation validated by postinstrumentation open dissection
-
Glanvill R, Boon JM, Birkholz F, et al. Superficial radial nerve injury during standard K-wire fixation of uncomplicated distal radius fractures. Orthopedics 2006; 29:639-642. A cadaver study that correlates nerve injury with percutaneous K-wire fixation validated by postinstrumentation open dissection.
-
(2006)
Orthopedics
, vol.29
, pp. 639-642
-
-
Glanvill, R.1
Boon, J.M.2
Birkholz, F.3
-
2
-
-
31544452761
-
Anatomy of the distal brachioradialis and its potential relationship to distal radius fracture
-
Koh S, Andersen CR, Buford WL Jr, et al. Anatomy of the distal brachioradialis and its potential relationship to distal radius fracture. J Hand Surg 2006; 31A:2-8.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 2-8
-
-
Koh, S.1
Andersen, C.R.2
Buford Jr, W.L.3
-
3
-
-
33846042110
-
Missed opportunities in patients with osteoporosis and distal radius fractures
-
A retrospective study looking at the rate of diagnostic or therapeutic interventions by orthopaedists treating patients with distal radius fractures
-
Freedman BA, Potter BK, Nesti LJ, et al. Missed opportunities in patients with osteoporosis and distal radius fractures. Clin Orthop 2007; 454:202-206. A retrospective study looking at the rate of diagnostic or therapeutic interventions by orthopaedists treating patients with distal radius fractures.
-
(2007)
Clin Orthop
, vol.454
, pp. 202-206
-
-
Freedman, B.A.1
Potter, B.K.2
Nesti, L.J.3
-
4
-
-
33846101160
-
Predictors of functional outcomes after surgical treatment of distal radius fractures
-
This paper is a prospective study that examines what patient factors are important for predicting treatment outcome at one year after a distal radius fracture
-
Chung KC, Kotsis SV, Kim HM. Predictors of functional outcomes after surgical treatment of distal radius fractures. J Hand Surg 2007; 32A:76-83. This paper is a prospective study that examines what patient factors are important for predicting treatment outcome at one year after a distal radius fracture.
-
(2007)
J Hand Surg
, vol.32 A
, pp. 76-83
-
-
Chung, K.C.1
Kotsis, S.V.2
Kim, H.M.3
-
5
-
-
33845992571
-
Responsiveness of the Michigan Hand Outcomes Questionnaire and physical measurements in outcome studies of distal radius fracture treatment
-
Kotsis SV, Lau FH, Chung KC. Responsiveness of the Michigan Hand Outcomes Questionnaire and physical measurements in outcome studies of distal radius fracture treatment. J Hand Surg 2007; 32A:84-90.
-
(2007)
J Hand Surg
, vol.32 A
, pp. 84-90
-
-
Kotsis, S.V.1
Lau, F.H.2
Chung, K.C.3
-
6
-
-
33646506008
-
Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study
-
Koh S, Morris RP, Patterson RM, et al. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg 2006; 31A:771-779.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 771-779
-
-
Koh, S.1
Morris, R.P.2
Patterson, R.M.3
-
7
-
-
33748746234
-
A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model
-
Liporace FA, Kubiak EN, Jeong GK, et al. A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model. J Trauma Injury, Infect Crit Care 2006; 61:668-672.
-
(2006)
J Trauma Injury, Infect Crit Care
, vol.61
, pp. 668-672
-
-
Liporace, F.A.1
Kubiak, E.N.2
Jeong, G.K.3
-
8
-
-
33644645688
-
Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: Cyclic testing in a C2-type distal radius cadaver fracture model
-
Taylor KF, Parks BG, Segalman KA. Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model. J Hand Surg 2006; 31A:373-381.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 373-381
-
-
Taylor, K.F.1
Parks, B.G.2
Segalman, K.A.3
-
9
-
-
33750802999
-
Internal fixation of dorsally displaced fractures of the distal part of the radius: A biomechanical analysis of volar plate fracture stability
-
Willis AA, Kutsumi K, Zobitz ME, Cooney WP. Internal fixation of dorsally displaced fractures of the distal part of the radius: a biomechanical analysis of volar plate fracture stability. J Bone Joint Surg 2006; 88A:2411-2417.
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 2411-2417
-
-
Willis, A.A.1
Kutsumi, K.2
Zobitz, M.E.3
Cooney, W.P.4
-
10
-
-
33846624729
-
Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model
-
Grindel SI, Wang M, Gerlach M, et al. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model. J Hand Surg 2007; 32A:194-199.
-
(2007)
J Hand Surg
, vol.32 A
, pp. 194-199
-
-
Grindel, S.I.1
Wang, M.2
Gerlach, M.3
-
11
-
-
34250651062
-
Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
-
Blythe M, Stoffel K, Jarrett P, Kuster M. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: a biomechanical study in cadavers. J Hand Surg 2006; 31A:1587-1593.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 1587-1593
-
-
Blythe, M.1
Stoffel, K.2
Jarrett, P.3
Kuster, M.4
-
12
-
-
34250617241
-
-
Drobetz H, Bryant AL, Pokomy T, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - a biomechanic study in a cadaveric model. J Hand Surg 2006; 31A:615-622. A cadaveric biomechanical study examining the optimal plate position that will withstand postoperative loads for volar plate fixation.
-
Drobetz H, Bryant AL, Pokomy T, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - a biomechanic study in a cadaveric model. J Hand Surg 2006; 31A:615-622. A cadaveric biomechanical study examining the optimal plate position that will withstand postoperative loads for volar plate fixation.
-
-
-
-
13
-
-
34250625835
-
A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures
-
This paper reviews and compares a new method of treating high-energy distal radius fractures with the traditional method, external fixation, in a biomechanical model
-
Wolf JC, Weil WM, Hanel DP, Trumble TE. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures. J Hand Surg 2006; 31A:1578-1586. This paper reviews and compares a new method of treating high-energy distal radius fractures with the traditional method, external fixation, in a biomechanical model.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 1578-1586
-
-
Wolf, J.C.1
Weil, W.M.2
Hanel, D.P.3
Trumble, T.E.4
-
14
-
-
33646837139
-
Bridge plating of distal radius fractures: The Harborview method
-
A review of the authors' technique for 'internal external fixation' of the distal radius with a radiocarpal spanning plate for high-energy distal radius fractures
-
Hanel DP, Lu TS, Weil WM. Bridge plating of distal radius fractures: the Harborview method. Clin Orthop 2006; 445:91-99. A review of the authors' technique for 'internal external fixation' of the distal radius with a radiocarpal spanning plate for high-energy distal radius fractures.
-
(2006)
Clin Orthop
, vol.445
, pp. 91-99
-
-
Hanel, D.P.1
Lu, T.S.2
Weil, W.M.3
-
15
-
-
0024309328
-
Stability assessment of distal radius fractures
-
Lafontaine M, Hardy D, Delince P. Stability assessment of distal radius fractures. Injury 1989; 20:208-210.
-
(1989)
Injury
, vol.20
, pp. 208-210
-
-
Lafontaine, M.1
Hardy, D.2
Delince, P.3
-
16
-
-
33748475155
-
Predcition of instability in distal radius fractures
-
Mackenney PJ, McQueen MM, Elton R. Predcition of instability in distal radius fractures. J Bone Joint Surg 2006; 88A:1944-1951.
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 1944-1951
-
-
Mackenney, P.J.1
McQueen, M.M.2
Elton, R.3
-
17
-
-
34447623277
-
-
Jaremko JL, Lambert RG, Rowe BH, et al. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment? Clin Radiol 2007; 62:65-72. Aprospective study that correlates functional outcome with radiographic parameters in non-operatively managed distal radius fractures.
-
Jaremko JL, Lambert RG, Rowe BH, et al. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment? Clin Radiol 2007; 62:65-72. Aprospective study that correlates functional outcome with radiographic parameters in non-operatively managed distal radius fractures.
-
-
-
-
18
-
-
33744804269
-
The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures
-
This paper examines the inter and intraobserver reliability of three-dimensional computed tomography for distal radius fracture classification and whether it would change operative management
-
Harness NG, Ring D, Zurakowski D, et al. The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures. J Bone Joint Surg 2006; 88A:1315-1323. This paper examines the inter and intraobserver reliability of three-dimensional computed tomography for distal radius fracture classification and whether it would change operative management.
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 1315-1323
-
-
Harness, N.G.1
Ring, D.2
Zurakowski, D.3
-
19
-
-
33646048306
-
Fifteen-year outcome of displaced intra-articular fractures of the distal radius
-
The authors examine the development of arthritis and other radiographic parameters long term to see if it correlates with upper extremity function
-
Goldfarb CA, Rudzki JR, Catalano LW, et al. Fifteen-year outcome of displaced intra-articular fractures of the distal radius. J Hand Surg 2006; 31A:633-639. The authors examine the development of arthritis and other radiographic parameters long term to see if it correlates with upper extremity function.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 633-639
-
-
Goldfarb, C.A.1
Rudzki, J.R.2
Catalano, L.W.3
-
20
-
-
0030767613
-
Displaced intra-articular fractures of the distal aspect of the radius. Long-term results in young adults after open reduction and internal fixation
-
Catalano LW, Cole RJ, Gelberman RH, et al. Displaced intra-articular fractures of the distal aspect of the radius. Long-term results in young adults after open reduction and internal fixation. J Bone Joint Surg 1997; 79A: 1290-1302.
-
(1997)
J Bone Joint Surg
, vol.79 A
, pp. 1290-1302
-
-
Catalano, L.W.1
Cole, R.J.2
Gelberman, R.H.3
-
21
-
-
33646510358
-
A comparison of immediate postreduction splinting constructs for controlling initial displacement of fractures of the distal radius: A prospective randomized study of long-arm versus short-arm splinting
-
A randomized controlled trial focusing on the debate over short-arm versus long-arm immobilization in the treatment of distal radius fractures and short-term outcomes
-
Bong MR, Egol KA, Leibman M, Koval KJ. A comparison of immediate postreduction splinting constructs for controlling initial displacement of fractures of the distal radius: a prospective randomized study of long-arm versus short-arm splinting. J Hand Surg 2006; 31A:766-770. A randomized controlled trial focusing on the debate over short-arm versus long-arm immobilization in the treatment of distal radius fractures and short-term outcomes.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 766-770
-
-
Bong, M.R.1
Egol, K.A.2
Leibman, M.3
Koval, K.J.4
-
22
-
-
33646501467
-
-
Rosati M, Bertagnini S, Digrandi G, Sala C. Percutaneous pinning for fractures of the distal radius. Acta Orthopaedica Belgica 2006; 72:138-146. A retrospective review of 106 patients treated with percutaneous pinning that looks at functional outcome and radiographic parameters at an average of 57 months follow-up.
-
Rosati M, Bertagnini S, Digrandi G, Sala C. Percutaneous pinning for fractures of the distal radius. Acta Orthopaedica Belgica 2006; 72:138-146. A retrospective review of 106 patients treated with percutaneous pinning that looks at functional outcome and radiographic parameters at an average of 57 months follow-up.
-
-
-
-
23
-
-
33646106933
-
Use of an external fixation combined with the buttress-maintain pinning method in treating comminuted distal radius fractures in osteoporotic patients
-
Fu YC, Chien SH, Huang PJ, et al. Use of an external fixation combined with the buttress-maintain pinning method in treating comminuted distal radius fractures in osteoporotic patients. J Trauma Injury, Infect Crit Care 2006; 60:330-333.
-
(2006)
J Trauma Injury, Infect Crit Care
, vol.60
, pp. 330-333
-
-
Fu, Y.C.1
Chien, S.H.2
Huang, P.J.3
-
24
-
-
0032461601
-
Intrafocal (Kapandji) pinning of distal radius fractures with and without external fixation
-
Trumble TE, Wagner W, Hanel DP, et al. Intrafocal (Kapandji) pinning of distal radius fractures with and without external fixation. J Hand Surg 1998; 23A:381-394.
-
(1998)
J Hand Surg
, vol.23 A
, pp. 381-394
-
-
Trumble, T.E.1
Wagner, W.2
Hanel, D.P.3
-
25
-
-
31844453329
-
Treatment of external fixation pins about the wrist: A prospective, randomized trial
-
One hundred and twenty patients managed with an external fixation device were randomly assigned to one of three pin care treatments and followed for complications
-
Egol KA, Paksima N, Puopolo S, et al. Treatment of external fixation pins about the wrist: a prospective, randomized trial. J Bone Joint Surg 2006; 88A:349-354. One hundred and twenty patients managed with an external fixation device were randomly assigned to one of three pin care treatments and followed for complications.
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 349-354
-
-
Egol, K.A.1
Paksima, N.2
Puopolo, S.3
-
26
-
-
0032460038
-
Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
-
Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg 1998; 23A:737-741.
-
(1998)
J Hand Surg
, vol.23 A
, pp. 737-741
-
-
Kambouroglou, G.K.1
Axelrod, T.S.2
-
27
-
-
0034302091
-
Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: A case report
-
Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop 2000; 29:789-791.
-
(2000)
Am J Orthop
, vol.29
, pp. 789-791
-
-
Lowry, K.J.1
Gainor, B.J.2
Hoskins, J.S.3
-
28
-
-
0034068196
-
Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate
-
Schnur DP, Chang B. Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Ann Plast Surg 2000; 44:564-566.
-
(2000)
Ann Plast Surg
, vol.44
, pp. 564-566
-
-
Schnur, D.P.1
Chang, B.2
-
29
-
-
33750473404
-
Dorsal (AO/ASIF) pi-plate osteosynthesis in the treatment of distal intraarticular radius fractures
-
Suckel A, Sies S, Munst P. Dorsal (AO/ASIF) pi-plate osteosynthesis in the treatment of distal intraarticular radius fractures. J Hand Surg 2006; 31B: 673-679.
-
(2006)
J Hand Surg
, vol.31 B
, pp. 673-679
-
-
Suckel, A.1
Sies, S.2
Munst, P.3
-
30
-
-
33644637372
-
Treatment of distal radius fractures with a low-profile dorsal plating system: An outcomes assessment
-
This study is an excellent review of the outcomes with a lower profile dorsal plate that theoretically should not irritate the extensor tendons as much as older designs did
-
Simic PM, Robison J, Gardner MJ, et al. Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg 2006; 31A:382-386. This study is an excellent review of the outcomes with a lower profile dorsal plate that theoretically should not irritate the extensor tendons as much as older designs did.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 382-386
-
-
Simic, P.M.1
Robison, J.2
Gardner, M.J.3
-
31
-
-
33748166135
-
-
Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg 2006; 31A:1061-1067. A median 18-month follow-up of functional outcomes, radiographic data and complications.
-
Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg 2006; 31A:1061-1067. A median 18-month follow-up of functional outcomes, radiographic data and complications.
-
-
-
-
32
-
-
0036130725
-
Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
-
Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 2002; 27A:205-215.
-
(2002)
J Hand Surg
, vol.27 A
, pp. 205-215
-
-
Orbay, J.L.1
Fernandez, D.L.2
-
33
-
-
33644649770
-
-
Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg 2006; 31A:359-365. One of the better papers on outcomes and complications of distal radius fracture treatment with volar plating, with an average 17-month follow-up.
-
Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg 2006; 31A:359-365. One of the better papers on outcomes and complications of distal radius fracture treatment with volar plating, with an average 17-month follow-up.
-
-
-
-
34
-
-
85130089022
-
-
Chung KC, Watt AJ, Kotsis SV, et al. Treatment of unstable distal radius fractures with the volar locking plating system. J Bone Joint Surg 2006; 88A: 2687-2694. A prospective study focusing on comparing short-term (less than one year) follow-up.
-
Chung KC, Watt AJ, Kotsis SV, et al. Treatment of unstable distal radius fractures with the volar locking plating system. J Bone Joint Surg 2006; 88A: 2687-2694. A prospective study focusing on comparing short-term (less than one year) follow-up.
-
-
-
-
35
-
-
33750468969
-
Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: A single center study of 102 patients over a 2-year period
-
Gruber G, Bernhardt GA, Kohler G, Gruber K. Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year period. Acta Orthop Trauma Surg 2006; 126:680-685.
-
(2006)
Acta Orthop Trauma Surg
, vol.126
, pp. 680-685
-
-
Gruber, G.1
Bernhardt, G.A.2
Kohler, G.3
Gruber, K.4
-
36
-
-
33749446244
-
Two potential causes of EPL rupture after distal radius volar plate fixation
-
As the potential complications of volar plating now become apparent, this case report combines a cadaveric dissection and intraoperative examination of the dorsal compartment while applying a volar plate to attempt to determine the cause of extensor tendon rupture
-
Benson EC, DeCarvalho A, Mikola EA, et al. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop 2006; 451:218-222. As the potential complications of volar plating now become apparent, this case report combines a cadaveric dissection and intraoperative examination of the dorsal compartment while applying a volar plate to attempt to determine the cause of extensor tendon rupture.
-
(2006)
Clin Orthop
, vol.451
, pp. 218-222
-
-
Benson, E.C.1
DeCarvalho, A.2
Mikola, E.A.3
-
38
-
-
33749255185
-
-
Benson LS, Minihane KP, Stern LD, et al. The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg 2006; 31A:1333-1339. A single surgeon's experience with 85 fractures retrospectively reviewed at an average 32-month follow-up.
-
Benson LS, Minihane KP, Stern LD, et al. The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg 2006; 31A:1333-1339. A single surgeon's experience with 85 fractures retrospectively reviewed at an average 32-month follow-up.
-
-
-
-
39
-
-
33646838952
-
Fixation of distal radius fractures using a fragment-specific system
-
Schnall SB, Kim BJ, Abramo A, Kopylov P. Fixation of distal radius fractures using a fragment-specific system. Clin Orthop 2006; 445:51-57.
-
(2006)
Clin Orthop
, vol.445
, pp. 51-57
-
-
Schnall, S.B.1
Kim, B.J.2
Abramo, A.3
Kopylov, P.4
-
40
-
-
33745727001
-
Fractures of the dorsal articular margin of the distal part of the radius with dorsal radiocarpal subluxation
-
This paper shows the complexity of distal radius fractures and how a 'one plate fits all' treatment is not applicable. The authors discuss four patterns of injury and the important treatment recommendations for each
-
Lozano-Calderon SA, Doornberg J, Ring D. Fractures of the dorsal articular margin of the distal part of the radius with dorsal radiocarpal subluxation. J Bone Joint Surg 2006; 88A:1486-1493. This paper shows the complexity of distal radius fractures and how a 'one plate fits all' treatment is not applicable. The authors discuss four patterns of injury and the important treatment recommendations for each.
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 1486-1493
-
-
Lozano-Calderon, S.A.1
Doornberg, J.2
Ring, D.3
-
41
-
-
22544441313
-
A randomized prospective study on the treatment of intra-articular distal radius fractures: Open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation
-
Grewal R, Perey B, Wilmlink M, Stothers K. A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation. J Hand Surg 2005; 30A:764-772.
-
(2005)
J Hand Surg
, vol.30 A
, pp. 764-772
-
-
Grewal, R.1
Perey, B.2
Wilmlink, M.3
Stothers, K.4
-
42
-
-
20844452245
-
Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: A randomised, controlled trial
-
Kreder HJ, Hanel DP, Agel J, et al. Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: a randomised, controlled trial. J Bone Joint Surg 2005; 87B:829-836.
-
(2005)
J Bone Joint Surg
, vol.87 B
, pp. 829-836
-
-
Kreder, H.J.1
Hanel, D.P.2
Agel, J.3
-
43
-
-
33744496840
-
A randomized, controlled trial of distal radius fractures with metaphyseal displacement but without joint incongruity: Closed reduction and casting versus closed reduction, spanning external fixation, and optional percutaneous K-wires
-
This is an intriguing study that randomly assigned patients to operative compared with non-operative treatment for fractures of the distal radius only involving the metaphysis
-
Kreder HJ, Agel J, McKee M, et al. A randomized, controlled trial of distal radius fractures with metaphyseal displacement but without joint incongruity: closed reduction and casting versus closed reduction, spanning external fixation, and optional percutaneous K-wires. J Orthop Trauma 2006; 20:115-121. This is an intriguing study that randomly assigned patients to operative compared with non-operative treatment for fractures of the distal radius only involving the metaphysis.
-
(2006)
J Orthop Trauma
, vol.20
, pp. 115-121
-
-
Kreder, H.J.1
Agel, J.2
McKee, M.3
-
44
-
-
31544472058
-
Volar versus dorsal plating in the management of intra-articular distal radius fractures
-
Although this paper does not compare one particular volar plate with a dorsal plate, some valuable insights and trends can be obtained from a careful review of the authors' data
-
Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg 2006; 31A:9-16. Although this paper does not compare one particular volar plate with a dorsal plate, some valuable insights and trends can be obtained from a careful review of the authors' data.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 9-16
-
-
Ruch, D.S.1
Papadonikolakis, A.2
-
45
-
-
33646034895
-
The use of tricorticocancellous bone graft in severely comminuted intra-articular fractures of the distal radius
-
Rogachefsky RA, Ouellette EA, Sun S, Applegate B. The use of tricorticocancellous bone graft in severely comminuted intra-articular fractures of the distal radius. J Hand Surg 2006; 31A:623-632.
-
(2006)
J Hand Surg
, vol.31 A
, pp. 623-632
-
-
Rogachefsky, R.A.1
Ouellette, E.A.2
Sun, S.3
Applegate, B.4
-
46
-
-
33144471123
-
Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures
-
A non-randomized study comparing bone cement to autologous graft in distal radius fractures treated with external fixation and pinning
-
Tyllianakis ME, Panagopoulous A, Giannikas D, et al. Graft-supplemented, augmented external fixation in the treatment of intra-articular distal radial fractures. Orthopedics 2006; 29:139-144. A non-randomized study comparing bone cement to autologous graft in distal radius fractures treated with external fixation and pinning.
-
(2006)
Orthopedics
, vol.29
, pp. 139-144
-
-
Tyllianakis, M.E.1
Panagopoulous, A.2
Giannikas, D.3
-
47
-
-
33745279636
-
Cancellous allograft versus autologous bone grafting for repair of comminuted distal radius fractures: A prospective, randomized trial
-
Care, A randomized study assessing the outcomes after treatment with either autologous iliac crest or cancellous chips to fill dorsal metaphyseal voids
-
Rajan GP, Fornaro J, Trentz O, Zellweger R. Cancellous allograft versus autologous bone grafting for repair of comminuted distal radius fractures: a prospective, randomized trial. J Trauma Injury, Infect Crit Care 2006; 60: 1322-1329. A randomized study assessing the outcomes after treatment with either autologous iliac crest or cancellous chips to fill dorsal metaphyseal voids.
-
(2006)
J Trauma Injury, Infect Crit
, vol.60
, pp. 1322-1329
-
-
Rajan, G.P.1
Fornaro, J.2
Trentz, O.3
Zellweger, R.4
-
48
-
-
30544446942
-
Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute
-
An intriguing concept showcasing the results of a unique plating system from a group of surgeons in the UK. They examine their results and give recommendations on indications for the use of this bio-absorbable distal radius plate
-
Gangopadhyay S, Ravi K, Packer G. Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute. J Hand Surg 2006; 31B:93-100. An intriguing concept showcasing the results of a unique plating system from a group of surgeons in the UK. They examine their results and give recommendations on indications for the use of this bio-absorbable distal radius plate.
-
(2006)
J Hand Surg
, vol.31 B
, pp. 93-100
-
-
Gangopadhyay, S.1
Ravi, K.2
Packer, G.3
|