메뉴 건너뛰기




Volumn 16, Issue 6, 2007, Pages 787-793

Transcranial motor-evoked potentials monitoring can detect spinal cord ischemia more rapidly than spinal cord-evoked potentials monitoring during aortic occlusion in rats

Author keywords

Motor evoked monitoring; Sensory evoked monitoring; Spinal cord ischemia; Spinal cord monitoring

Indexed keywords

AMPLITUDE MODULATION; ANIMAL EXPERIMENT; ANIMAL MODEL; AORTA OCCLUSION; ARTICLE; BALLOON CATHETER; BIOASSAY; CONTROLLED STUDY; EVOKED MUSCLE RESPONSE; EVOKED SPINAL CORD RESPONSE; INTERMETHOD COMPARISON; MALE; NONHUMAN; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PROBABILITY; QUANTITATIVE ASSAY; RAT; SIGNAL TRANSDUCTION; SPINAL CORD ISCHEMIA; STATISTICAL ANALYSIS;

EID: 34250615181     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-006-0165-1     Document Type: Article
Times cited : (19)

References (27)
  • 1
    • 0001222558 scopus 로고
    • Neurologic complications of aortic surgery
    • Adams DH, Van Geertruyden HH (1956) Neurologic complications of aortic surgery. Ann Surg 144:574-610
    • (1956) Ann Surg , vol.144 , pp. 574-610
    • Adams, D.H.1    Van Geertruyden, H.H.2
  • 2
    • 0021227205 scopus 로고
    • Cortical evoked potential monitoring: A system for intraoperative monitoring of spinal cord function
    • Brown RH, Nash CL, Berilla JA, Amaddio MD (1984) Cortical evoked potential monitoring: a system for intraoperative monitoring of spinal cord function. Spine 9:256-261
    • (1984) Spine , vol.9 , pp. 256-261
    • Brown, R.H.1    Nash, C.L.2    Berilla, J.A.3    Amaddio, M.D.4
  • 3
    • 0019980349 scopus 로고
    • Intraoperative detection of spinal cord ischemia using somatosensory cortical evoked potentials during thoracic aortic occlusion
    • Coles JG, Wilson GJ, Sima AF, Klement P, Tait GA (1982) Intraoperative detection of spinal cord ischemia using somatosensory cortical evoked potentials during thoracic aortic occlusion. Ann Thorac Surg 34:299-306
    • (1982) Ann Thorac Surg , vol.34 , pp. 299-306
    • Coles, J.G.1    Wilson, G.J.2    Sima, A.F.3    Klement, P.4    Tait, G.A.5
  • 4
    • 0022626154 scopus 로고
    • Thoracoabdominal aortic aneurysms: Preoperative and intraoperative factors determining immediate- and long-term results of operations in 605 patients
    • Crawford ES, Crawford JL, Safi HJ, Coselli JS, Hess KR, Brooks B, Norton HJ, Glaeser DH (1986) Thoracoabdominal aortic aneurysms: preoperative and intraoperative factors determining immediate- and long-term results of operations in 605 patients. J Vasc Surg 3:389-404
    • (1986) J Vasc Surg , vol.3 , pp. 389-404
    • Crawford, E.S.1    Crawford, J.L.2    Safi, H.J.3    Coselli, J.S.4    Hess, K.R.5    Brooks, B.6    Norton, H.J.7    Glaeser, D.H.8
  • 6
    • 0035216635 scopus 로고    scopus 로고
    • Spinal cord monitoring: Somatosensory- and motor-evoked potentials
    • de Haan P, Kalkman CJ (2001) Spinal cord monitoring: somatosensory- and motor-evoked potentials. Anesth Clin North Am 19:923-945
    • (2001) Anesth Clin North Am , vol.19 , pp. 923-945
    • De Haan, P.1    Kalkman, C.J.2
  • 7
    • 0031032060 scopus 로고    scopus 로고
    • Efficacy of transcranial motor-evoked myogenic potentials to detect spinal cord ischemia during operations for thoracoabdominal aneurysms
    • de Haan P, Kalkman CJ, de Mol BD, Ubags LH, Veldman DJ, Jacobs MJ (1997) Efficacy of transcranial motor-evoked myogenic potentials to detect spinal cord ischemia during operations for thoracoabdominal aneurysms. J Thorac Cardiovasc Surg 113:87-100
    • (1997) J Thorac Cardiovasc Surg , vol.113 , pp. 87-100
    • De Haan, P.1    Kalkman, C.J.2    De Mol, B.D.3    Ubags, L.H.4    Veldman, D.J.5    Jacobs, M.J.6
  • 8
    • 0017407950 scopus 로고
    • Corticospinal connections in the rat. I. Monosynaptic and polysynaptic responses of cervical motorneurons to epicortical stimulation
    • Elger CE, Speckmann EJ, Caspers H, Janzen RW (1977) Corticospinal connections in the rat. I. Monosynaptic and polysynaptic responses of cervical motorneurons to epicortical stimulation. Exp Brain Res 28:385-404
    • (1977) Exp Brain Res , vol.28 , pp. 385-404
    • Elger, C.E.1    Speckmann, E.J.2    Caspers, H.3    Janzen, R.W.4
  • 9
    • 0023209107 scopus 로고
    • Motor evoked potentials recorded from normal and spinalo cord-injured rats
    • Fehlings MG, Tator CH, Linden RD, Piper IR (1987) Motor evoked potentials recorded from normal and spinalo cord-injured rats. Neurosurgery 20:125-130
    • (1987) Neurosurgery , vol.20 , pp. 125-130
    • Fehlings, M.G.1    Tator, C.H.2    Linden, R.D.3    Piper, I.R.4
  • 10
    • 0031607752 scopus 로고    scopus 로고
    • Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: A critical overview
    • Gharagozloo F, Neville RFJ, Cox JL (1998) Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: a critical overview. Semin Thorac Cardiovasc Surg 10:73-86
    • (1998) Semin Thorac Cardiovasc Surg , vol.10 , pp. 73-86
    • Gharagozloo, F.1    Neville, R.F.J.2    Cox, J.L.3
  • 12
    • 0032899578 scopus 로고    scopus 로고
    • Strategies to prevent neurologic deficit based on motor-evoked potentials in type I and II thoracoabdominal aortic aneurysm repair
    • Jacobs M, Meylaerts SA, de Haan P, de Mol BA, Kalkman CJ (1999) Strategies to prevent neurologic deficit based on motor-evoked potentials in type I and II thoracoabdominal aortic aneurysm repair. J Vasc Surg 29:48-57
    • (1999) J Vasc Surg , vol.29 , pp. 48-57
    • Jacobs, M.1    Meylaerts, S.A.2    De Haan, P.3    De Mol, B.A.4    Kalkman, C.J.5
  • 13
    • 0037371426 scopus 로고    scopus 로고
    • Intrathecal administration of morphine, but not small dose, induced spastic paraparesis after a noninjurious interval of aortic occlusion in rats
    • Kakinohana M, Fuchigami T, Nakamura S, Sasara T, Kawabata T, Sugahara K (2003) Intrathecal administration of morphine, but not small dose, induced spastic paraparesis after a noninjurious interval of aortic occlusion in rats. Anesth Analg 96:769-775
    • (2003) Anesth Analg , vol.96 , pp. 769-775
    • Kakinohana, M.1    Fuchigami, T.2    Nakamura, S.3    Sasara, T.4    Kawabata, T.5    Sugahara, K.6
  • 14
    • 11144330510 scopus 로고    scopus 로고
    • Myogenic transcranial motor evoked potentials monitoring cannot always predict neurological outcome after spinal cord ischemia in rats
    • Kakinohana M, Kawabata T, Miyata Y, Sugahara K (2005) Myogenic transcranial motor evoked potentials monitoring cannot always predict neurological outcome after spinal cord ischemia in rats. J Thorac Cardiovasc Surg 129:46-52
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 46-52
    • Kakinohana, M.1    Kawabata, T.2    Miyata, Y.3    Sugahara, K.4
  • 15
    • 0036300945 scopus 로고    scopus 로고
    • The role of transcranial motor evoked potentials in predicting neurologic and histopathologic outcome after experimental spinal cord ischemia
    • Lips J, de Haan P, de Jager SW, Vanicky I, Jacobs MJ, Kalkman CJ (2002) The role of transcranial motor evoked potentials in predicting neurologic and histopathologic outcome after experimental spinal cord ischemia. Anesthesiology 97:183-191
    • (2002) Anesthesiology , vol.97 , pp. 183-191
    • Lips, J.1    De Haan, P.2    De Jager, S.W.3    Vanicky, I.4    Jacobs, M.J.5    Kalkman, C.J.6
  • 17
    • 0023808397 scopus 로고
    • Dissociation of muscle action potentials and spinal somatosensory evoked potentials after ischemic damage of spinal cord
    • Machida M, Weinstein SL, Yamada T, Kimura J, Toriyama S (1988) Dissociation of muscle action potentials and spinal somatosensory evoked potentials after ischemic damage of spinal cord. Spine 13:1119-1124
    • (1988) Spine , vol.13 , pp. 1119-1124
    • MacHida, M.1    Weinstein, S.L.2    Yamada, T.3    Kimura, J.4    Toriyama, S.5
  • 18
    • 0024844779 scopus 로고
    • Early neurohistopathological changes of canine lumbosacral spinal cord segments in ischemia-reperfusion-induced paraplegia
    • Marsala J, Sulla I, Santa M, Marsala M, Mechirova E, Jalc P (1989) Early neurohistopathological changes of canine lumbosacral spinal cord segments in ischemia-reperfusion-induced paraplegia. Neurosci Lett 106:83-88
    • (1989) Neurosci Lett , vol.106 , pp. 83-88
    • Marsala, J.1    Sulla, I.2    Santa, M.3    Marsala, M.4    Mechirova, E.5    Jalc, P.6
  • 19
    • 0024394946 scopus 로고
    • Improvement of energy state and basic modification of neuropathological damage in rabbits as a result of graded postischemic spinal cord reoxygenation
    • Marsala M, Danielisova V, Chavko M, Hornakova A, Marsala J (1989) Improvement of energy state and basic modification of neuropathological damage in rabbits as a result of graded postischemic spinal cord reoxygenation. Exp Neurol 105:93-103
    • (1989) Exp Neurol , vol.105 , pp. 93-103
    • Marsala, M.1    Danielisova, V.2    Chavko, M.3    Hornakova, A.4    Marsala, J.5
  • 20
    • 0033510556 scopus 로고    scopus 로고
    • Comparison of transcranial motor evoked potentials and somatosensory evoked potentials during thoracoabdominal aortic aneurysm repair
    • Meylaerts SA, Jacobs MJ, van Iterson V, De Haan P, Kalkman CJ (1999) Comparison of transcranial motor evoked potentials and somatosensory evoked potentials during thoracoabdominal aortic aneurysm repair. Ann Surg 230:742-749
    • (1999) Ann Surg , vol.230 , pp. 742-749
    • Meylaerts, S.A.1    Jacobs, M.J.2    Van Iterson, V.3    De Haan, P.4    Kalkman, C.J.5
  • 21
    • 0025891974 scopus 로고
    • Motor evoked potentials elicited from pyramidal stimulation and recorded from the spinal cord in the rat
    • Ryder J, Zappulla R, Nieves J (1991) Motor evoked potentials elicited from pyramidal stimulation and recorded from the spinal cord in the rat. Neurosurgery 28:550-558
    • (1991) Neurosurgery , vol.28 , pp. 550-558
    • Ryder, J.1    Zappulla, R.2    Nieves, J.3
  • 24
    • 0029745417 scopus 로고    scopus 로고
    • Effect of proximal arterial perfusion pressure on function, spinal cord blood flow, and histopathologic changes after increasing intervals of aortic occlusion in the rat
    • Taira Y, Marsala M (1996) Effect of proximal arterial perfusion pressure on function, spinal cord blood flow, and histopathologic changes after increasing intervals of aortic occlusion in the rat. Stroke 27:1850-1858
    • (1996) Stroke , vol.27 , pp. 1850-1858
    • Taira, Y.1    Marsala, M.2
  • 25
    • 84937089730 scopus 로고
    • Changes of evoked action potentials and histopathology of the spinal cord, and hind limb dysfunction in spinal cord ischemia of cats
    • Yamamoto N, Takano H, Kitagawa H, Kawaguchi Y, Tsuji H (1994) Changes of evoked action potentials and histopathology of the spinal cord, and hind limb dysfunction in spinal cord ischemia of cats. J Spinal Disord 7:285-295
    • (1994) J Spinal Disord , vol.7 , pp. 285-295
    • Yamamoto, N.1    Takano, H.2    Kitagawa, H.3    Kawaguchi, Y.4    Tsuji, H.5
  • 26
    • 0028062176 scopus 로고
    • Monitoring for spinal cord ischemia by use of the evoked spinal cord potentials during aortic aneurysm surgery
    • Yamamoto N, Takano H, Kitagawa H, Kawaguchi Y, Tsuji H, Uozaki Y (1994) Monitoring for spinal cord ischemia by use of the evoked spinal cord potentials during aortic aneurysm surgery. J Vasc Surg 20:826-833
    • (1994) J Vasc Surg , vol.20 , pp. 826-833
    • Yamamoto, N.1    Takano, H.2    Kitagawa, H.3    Kawaguchi, Y.4    Tsuji, H.5    Uozaki, Y.6
  • 27
    • 0026696401 scopus 로고
    • Quantal bioassay and stroke
    • Zivin JA, Waud DR (1992) Quantal bioassay and stroke. Stroke 23:767-773
    • (1992) Stroke , vol.23 , pp. 767-773
    • Zivin, J.A.1    Waud, D.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.