메뉴 건너뛰기




Volumn 51, Issue 6, 2007, Pages 770-772

Misplaced and dislodged endotracheal tubes may be detected by the defibrillator during cardiopulmonary resuscitation

Author keywords

Cardiopulmonary resuscitation; Electric impedance; Heart arrest; Intubation

Indexed keywords

ADULT; AGED; ARTICLE; CASE REPORT; DEFIBRILLATOR; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; ESOPHAGUS INTUBATION; FEMALE; HEART VENTRICLE FIBRILLATION; HUMAN; IMPEDANCE; MALE; PATIENT MONITORING; PRIORITY JOURNAL; RESUSCITATION; VENTILATED PATIENT;

EID: 34250351440     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2007.01317.x     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 28444490018 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2005 Section 4. Adult advanced life support
    • Nolan JP, Deakin CD, Soar J, Bottiger BW, Smith G. European Resuscitation Council Guidelines for Resuscitation 2005 Section 4. Adult advanced life support. Resuscitation 2005 67 (Suppl. 1 S39 86.
    • (2005) Resuscitation , vol.67 , Issue.1
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3    Bottiger, B.W.4    Smith, G.5
  • 2
    • 30144440856 scopus 로고    scopus 로고
    • Advanced cardiac life support before and after tracheal intubation - Direct measurements of quality
    • Kramer-Johansen J, Wik L, Steen PA. Advanced cardiac life support before and after tracheal intubation - direct measurements of quality. Resuscitation 2006 68 : 61 9.
    • (2006) Resuscitation , vol.68 , pp. 61-69
    • Kramer-Johansen, J.1    Wik, L.2    Steen, P.A.3
  • 3
    • 17844393537 scopus 로고    scopus 로고
    • Emergency physician verified prehospital intubation, missed rates by ground paramedics
    • Jones JH, Murphy MP, Dickson RL, Somerville GG. Emergency physician verified prehospital intubation, missed rates by ground paramedics. Acad Emerg Med 2003 10 : 448 9.
    • (2003) Acad Emerg Med , vol.10 , pp. 448-449
    • Jones, J.H.1    Murphy, M.P.2    Dickson, R.L.3    Somerville, G.G.4
  • 4
    • 0035148486 scopus 로고    scopus 로고
    • Misplaced endotracheal tubes by paramedics in an urban emergency medical services system
    • Katz SH, Falk JL. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med 2001 37 : 32 7.
    • (2001) Ann Emerg Med , vol.37 , pp. 32-37
    • Katz, S.H.1    Falk, J.L.2
  • 5
    • 28444491897 scopus 로고    scopus 로고
    • 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations
    • International Liason Committee on Resuscitation. Part 4: Advanced Life Support.
    • International Liason Committee on Resuscitation. 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Part 4: Advanced Life Support. Resuscitation 2005 67 : 213 47.
    • (2005) Resuscitation , vol.67 , pp. 213-247
  • 6
    • 0013780823 scopus 로고
    • Impedance measurement of tidal volume and ventilation
    • Hamilton LH, Beard JD, Kory RC. Impedance measurement of tidal volume and ventilation. J Appl Physiol 1965 20 : 565 8.
    • (1965) J Appl Physiol , vol.20 , pp. 565-568
    • Hamilton, L.H.1    Beard, J.D.2    Kory, R.C.3
  • 7
    • 33747468255 scopus 로고    scopus 로고
    • Thoracic impedance changes measured via defibrillator pads can monitor ventilation in critically ill patients and during cardiopulmonary resuscitation
    • Losert H, Risdal M, Sterz F et al. Thoracic impedance changes measured via defibrillator pads can monitor ventilation in critically ill patients and during cardiopulmonary resuscitation. Crit Care Med 2006 34 : 2399 405.
    • (2006) Crit Care Med , vol.34 , pp. 2399-2405
    • Losert, H.1    Risdal, M.2    Sterz, F.3
  • 8
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • Wik L, Kramer-Johansen J, Myklebust H et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. J Am Med Assoc 2005 293 : 299 304.
    • (2005) J Am Med Assoc , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3
  • 9
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study
    • Kramer-Johansen J, Myklebust H, Wik L et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006 71 : 283 92.
    • (2006) Resuscitation , vol.71 , pp. 283-292
    • Kramer-Johansen, J.1    Myklebust, H.2    Wik, L.3
  • 10
    • 33744830894 scopus 로고    scopus 로고
    • 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care
    • Part 7.2: Management of Cardiac Arrest.
    • 2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Part 7.2: Management of Cardiac Arrest. Circulation 2005 112 : I V58 66.
    • (2005) Circulation , vol.112 , Issue.1
  • 11
    • 0036844593 scopus 로고    scopus 로고
    • An assessment of the ability of impedance respirometry to distinguish oesophageal from tracheal intubation
    • Mehta KH, Turley A, Peyrasse P, Janes J, Hall JE. An assessment of the ability of impedance respirometry to distinguish oesophageal from tracheal intubation. Anaesthesia 2002 57 : 1090 3.
    • (2002) Anaesthesia , vol.57 , pp. 1090-1093
    • Mehta, K.H.1    Turley, A.2    Peyrasse, P.3    Janes, J.4    Hall, J.E.5
  • 12
    • 17844371707 scopus 로고    scopus 로고
    • The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system
    • Silvestri S, Ralls GA, Krauss B et al. The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system. Ann Emerg Med 2005 45 : 497 503.
    • (2005) Ann Emerg Med , vol.45 , pp. 497-503
    • Silvestri, S.1    Ralls, G.A.2    Krauss, B.3
  • 13
    • 0038806246 scopus 로고    scopus 로고
    • Stroke volumes and end-tidal carbon dioxide generated by precordial compression during ventricular fibrillation
    • Pernat A, Weil MH, Sun S, Tang W. Stroke volumes and end-tidal carbon dioxide generated by precordial compression during ventricular fibrillation. Crit Care Med 2003 31 : 1819 23.
    • (2003) Crit Care Med , vol.31 , pp. 1819-1823
    • Pernat, A.1    Weil, M.H.2    Sun, S.3    Tang, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.