Volumn 21, Issue 6, 2007, Pages 789-792

Comparison of Luneau SA disposable and Goldmann applanation tonometer readings

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL TRIAL; DIAGNOSTIC ACCURACY; DISPOSABLE EQUIPMENT; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; OBSERVER VARIATION; SINGLE BLIND PROCEDURE; TONOMETER; TONOMETRY;

EID: 34250339713     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/sj.eye.6702329     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0038408627 scopus 로고    scopus 로고
    • Retention of corneal epithelial cells following Goldmann tonometry: Implications for CJD risk
    • Lim R, Dhillon B, Kurian KM, Aspinall PA, Fernie K, Ironside JW. Retention of corneal epithelial cells following Goldmann tonometry: implications for CJD risk. Br J Ophthalmol 2003; 87(5): 583-586.
    • (2003) Br J Ophthalmol , vol.87 , Issue.5 , pp. 583-586
    • Lim, R.1    Dhillon, B.2    Kurian, K.M.3    Aspinall, P.A.4    Fernie, K.5    Ironside, J.W.6
  • 2
    • 0017387067 scopus 로고
    • Experimental Creutzfeldt-Jakob disease transmitted via the eye with infected cornea
    • Manuelidis EE, Angelo JN, Gorgacz EJ, Kim JH, Manuelidis L. Experimental Creutzfeldt-Jakob disease transmitted via the eye with infected cornea. N Engl J Med 1977; 296: 1334-1336.
    • (1977) N Engl J Med , vol.296 , pp. 1334-1336
    • Manuelidis, E.E.1    Angelo, J.N.2    Gorgacz, E.J.3    Kim, J.H.4    Manuelidis, L.5
  • 3
    • 0035491084 scopus 로고    scopus 로고
    • Possible iatrogenic transmission of Creutzfeldt-Jakob disease via tonometer tips: A review of the literature
    • Walia JS, Chronister CL. Possible iatrogenic transmission of Creutzfeldt-Jakob disease via tonometer tips: A review of the literature. Optometry 2001; 72: 649-652.
    • (2001) Optometry , vol.72 , pp. 649-652
    • Walia, J.S.1    Chronister, C.L.2
  • 4
    • 34250308228 scopus 로고    scopus 로고
    • Medical Device Agency AN 1999 (03). Single patient use of ophthalmic devices: Implications for clinical practice. Medical Devices Agency, October 1999.
    • Medical Device Agency AN 1999 (03). Single patient use of ophthalmic devices: Implications for clinical practice. Medical Devices Agency, October 1999.
  • 5
    • 22744437502 scopus 로고    scopus 로고
    • Disposable devices for measuring intraocular pressure: A clinical study to assess their accuracy
    • Bhatnagar A, Gupta AK. Disposable devices for measuring intraocular pressure: A clinical study to assess their accuracy. Eye 2005; 19(7): 752-754.
    • (2005) Eye , vol.19 , Issue.7 , pp. 752-754
    • Bhatnagar, A.1    Gupta, A.K.2
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 34250348163 scopus 로고    scopus 로고
    • Maino AP, Uddin HJ, Tullo AB. A comparison of clinical performance between disposable and Goldmann tonometers. Eye 2005 [E-pub ahead of print].
    • Maino AP, Uddin HJ, Tullo AB. A comparison of clinical performance between disposable and Goldmann tonometers. Eye 2005 [E-pub ahead of print].
  • 8
    • 0018734038 scopus 로고
    • Validity of the Imbert-Fick law for constant-pressure tonography
    • Viernstein LJ, Pollack IP. Validity of the Imbert-Fick law for constant-pressure tonography. Exp Eye Res 1979; 29(6): 587-594.
    • (1979) Exp Eye Res , vol.29 , Issue.6 , pp. 587-594
    • Viernstein, L.J.1    Pollack, I.P.2
  • 9
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993; 38: 1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 10
    • 0035056712 scopus 로고    scopus 로고
    • A comparative study of proxymetacaine-fluorescein and lignocaine-fluorescein use during applanation tonometry
    • Birchall W, Kumar V. A comparative study of proxymetacaine-fluorescein and lignocaine-fluorescein use during applanation tonometry. Br J Ophthalmol 2001; 85(4): 477-479.
    • (2001) Br J Ophthalmol , vol.85 , Issue.4 , pp. 477-479
    • Birchall, W.1    Kumar, V.2
  • 11
    • 1342346268 scopus 로고    scopus 로고
    • Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry
    • Goel S, Chua C, Dong B, Butcher M, AhFat A, Hindi SK et al. Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry. Eye 2004; 18(2): 175-178.
    • (2004) Eye , vol.18 , Issue.2 , pp. 175-178
    • Goel, S.1    Chua, C.2    Dong, B.3    Butcher, M.4    AhFat, A.5    Hindi, S.K.6