메뉴 건너뛰기




Volumn 19, Issue 3, 2007, Pages 207-212

Practice makes perfect? Evaluation of cricoid pressure task training for use within the algorithm for rapid sequence induction in critical care

Author keywords

Biofeedback trainer; Cricoid force; Cricoid pressure; Rapid sequence induction; Task trainer

Indexed keywords

ARTICLE; AUSTRALIA; CHI SQUARE TEST; CONFIDENCE INTERVAL; CONTROLLED STUDY; CRICOID; EMERGENCY CARE; EMERGENCY NURSE PRACTITIONER; EMERGENCY PHYSICIAN; HUMAN; INTENSIVE CARE; JOB PERFORMANCE; LARYNGOPHARYNGEAL REFLUX; LUNG VENTILATION; NURSING CARE; OBSERVATIONAL STUDY; PRESSURE; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE; TRAINING;

EID: 34250335300     PISSN: 17426731     EISSN: 17426723     Source Type: Journal    
DOI: 10.1111/j.1742-6723.2007.00921.x     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 49749217308 scopus 로고
    • Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia
    • Sellick BA. Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia. Lancet 1961 2 : 404 6.
    • (1961) Lancet , vol.2 , pp. 404-6
    • Sellick, B.A.1
  • 2
    • 34250315178 scopus 로고    scopus 로고
    • Australian Resuscitation Council Policy Statement Cricoid Pressure. 11.2.3.
    • Australian Resuscitation Council Policy Statement Cricoid Pressure. March 2001 11.2.3.
    • (2001)
  • 4
    • 0020641137 scopus 로고
    • The application of cricoid pressure: An assessment and a survey of its practice
    • Howells TH, Chamney AR, Wraight WJ, Simons RS. The application of cricoid pressure: an assessment and a survey of its practice. Anaesthesia 1983 38 : 457 60.
    • (1983) Anaesthesia , vol.38 , pp. 457-60
    • Howells, T.H.1    Chamney, A.R.2    Wraight, W.J.3    Simons, R.S.4
  • 5
    • 28544434568 scopus 로고    scopus 로고
    • Assessment of cricoid pressure application by emergency department staff
    • Clark RK, Trethewy C. Assessment of cricoid pressure application by emergency department staff. Emerg. Med. Australas. 2005 17 : 376 81.
    • (2005) Emerg. Med. Australas. , vol.17 , pp. 376-81
    • Clark, R.K.1    Trethewy, C.2
  • 6
    • 0032903249 scopus 로고    scopus 로고
    • Cricoid pressure: Knowledge and performance amongst anaesthetic assistants
    • Meek T, Gittins N, Duggan JE. Cricoid pressure: knowledge and performance amongst anaesthetic assistants. Anaesthesia 1999 54 : 59 63.
    • (1999) Anaesthesia , vol.54 , pp. 59-63
    • Meek, T.1    Gittins, N.2    Duggan, J.E.3
  • 7
    • 0034566724 scopus 로고    scopus 로고
    • Assessing the force generated with the application of cricoid pressure
    • Koziol CA, Cuddeford JD, Dan K. Assessing the force generated with the application of cricoid pressure. AORN J. 2000 72 : 1018 30.
    • (2000) AORN J. , vol.72 , pp. 1018-30
    • Koziol, C.A.1    Cuddeford, J.D.2    Dan, K.3
  • 8
    • 0034852350 scopus 로고    scopus 로고
    • Survey of cricoid pressure application by anaesthetists, operating department practitioners, intensive care and accident and emergency nurses
    • Matthews GA. Survey of cricoid pressure application by anaesthetists, operating department practitioners, intensive care and accident and emergency nurses. Anaesthesia 2001 56 : 915 17.
    • (2001) Anaesthesia , vol.56 , pp. 915-17
    • Matthews, G.A.1
  • 9
    • 0029968003 scopus 로고    scopus 로고
    • Cricoid pressure: Teaching the recommended level
    • Herman NL, Carter B, Van Decar TK. Cricoid pressure: teaching the recommended level. Anesth. Analg. 1996 83 : 859 63.
    • (1996) Anesth. Analg. , vol.83 , pp. 859-63
    • Herman, N.L.1    Carter, B.2    Van Decar, T.K.3
  • 11
    • 0029829396 scopus 로고    scopus 로고
    • Use of a mechanical simulator for training in applying cricoid pressure
    • Ashurst N, Rout CC, Rocke DA, Gouws E. Use of a mechanical simulator for training in applying cricoid pressure. Br. J. Anaesth. 1996 77 : 468 72.
    • (1996) Br. J. Anaesth. , vol.77 , pp. 468-72
    • Ashurst, N.1    Rout, C.C.2    Rocke, D.A.3    Gouws, E.4
  • 12
    • 0036843306 scopus 로고    scopus 로고
    • Learning to apply effective cricoid pressure using a part task trainer
    • Owen H, Follows V, Reynolds K, Burgess G, Plummer J. Learning to apply effective cricoid pressure using a part task trainer. Anaesthesia 2002 57 : 1098 101.
    • (2002) Anaesthesia , vol.57 , pp. 1098-101
    • Owen, H.1    Follows, V.2    Reynolds, K.3    Burgess, G.4    Plummer, J.5
  • 13
    • 0033841511 scopus 로고    scopus 로고
    • The 50-millilitre syringe as an inexpensive training aid in the application of cricoid pressure
    • Flucker CJ, Hart E, Weisz M, Griffiths R, Ruth M. The 50-millilitre syringe as an inexpensive training aid in the application of cricoid pressure. Eur. J. Anaesthesiol. 2000 17 : 443 7.
    • (2000) Eur. J. Anaesthesiol. , vol.17 , pp. 443-7
    • Flucker, C.J.1    Hart, E.2    Weisz, M.3    Griffiths, R.4    Ruth, M.5
  • 14
    • 0020623898 scopus 로고
    • The determination of an effective cricoid pressure
    • Wraight WJ, Chamney AR, Howells TH. The determination of an effective cricoid pressure. Anaesthesia 1983 38 : 461 6.
    • (1983) Anaesthesia , vol.38 , pp. 461-6
    • Wraight, W.J.1    Chamney, A.R.2    Howells, T.H.3
  • 15
    • 0026670039 scopus 로고
    • Regurgitation and oesophageal rupture with cricoid pressure: A cadaver study
    • Vanner RG, Pryle BJ. Regurgitation and oesophageal rupture with cricoid pressure: a cadaver study. Anaesthesia 1992 47 : 732 5.
    • (1992) Anaesthesia , vol.47 , pp. 732-5
    • Vanner, R.G.1    Pryle, B.J.2
  • 16
    • 0026558879 scopus 로고
    • Upper oesophageal sphincter pressure and the effect of cricoid pressure
    • Vanner RG, O'Dwyer JP, Pryle BJ, Reynolds F. Upper oesophageal sphincter pressure and the effect of cricoid pressure. Anaesthesia 1992 47 : 95 100.
    • (1992) Anaesthesia , vol.47 , pp. 95-100
    • Vanner, R.G.1    O'Dwyer, J.P.2    Pryle, B.J.3    Reynolds, F.4
  • 17
    • 0029056891 scopus 로고
    • The effect of cricoid pressure application on airway patency
    • Allman KG. The effect of cricoid pressure application on airway patency. J. Clin. Anesth. 1995 7 : 197 9.
    • (1995) J. Clin. Anesth. , vol.7 , pp. 197-9
    • Allman, K.G.1
  • 18
    • 0034059223 scopus 로고    scopus 로고
    • Airway obstruction with cricoid pressure
    • Hartsilver EL, Vanner RG. Airway obstruction with cricoid pressure. Anaesthesia 2000 55 : 208 11.
    • (2000) Anaesthesia , vol.55 , pp. 208-11
    • Hartsilver, E.L.1    Vanner, R.G.2
  • 19
    • 0034061295 scopus 로고    scopus 로고
    • The effect of cricoid pressure on the cricoid cartilage and vocal cords: An endoscopic study in anaesthetised patients
    • MacG Palmer JH, Ball DR. The effect of cricoid pressure on the cricoid cartilage and vocal cords: an endoscopic study in anaesthetised patients. Anaesthesia 2000 55 : 263 8.
    • (2000) Anaesthesia , vol.55 , pp. 263-8
    • MacG Palmer, J.H.1    Ball, D.R.2
  • 20
    • 0030886367 scopus 로고    scopus 로고
    • The effect of cricoid pressure and neck support on the view at laryngoscopy
    • Vanner RG, Clarke P, Moore WJ, Raferty S. The effect of cricoid pressure and neck support on the view at laryngoscopy. Anaesthesia 1997 52 : 896 900.
    • (1997) Anaesthesia , vol.52 , pp. 896-900
    • Vanner, R.G.1    Clarke, P.2    Moore, W.J.3    Raferty, S.4
  • 21
    • 2342522122 scopus 로고    scopus 로고
    • The effect of mechanically-induced cricoid force on lower oesophageal sphincter pressure in anaesthetised patients
    • Garrad A, Campbell A, Turley A, Hall J. The effect of mechanically-induced cricoid force on lower oesophageal sphincter pressure in anaesthetised patients. Anaesthesia 2004 59 : 435 9.
    • (2004) Anaesthesia , vol.59 , pp. 435-9
    • Garrad, A.1    Campbell, A.2    Turley, A.3    Hall, J.4
  • 22
    • 0032961036 scopus 로고    scopus 로고
    • Aspiration during anaesthesia. a review of 133 cases from Australian Incident Monitoring Study (AIMS)
    • Kluger MT, Short TG. Aspiration during anaesthesia. A review of 133 cases from Australian Incident Monitoring Study (AIMS). Anaesthesia 1999 54 : 19 26.
    • (1999) Anaesthesia , vol.54 , pp. 19-26
    • Kluger, M.T.1    Short, T.G.2
  • 23
    • 0036205067 scopus 로고    scopus 로고
    • A novel method of measuring cricoid force
    • Clayton TJ, Vanner RG. A novel method of measuring cricoid force. Anaesthesia 2002 57 : 326 9.
    • (2002) Anaesthesia , vol.57 , pp. 326-9
    • Clayton, T.J.1    Vanner, R.G.2
  • 24
    • 0031956862 scopus 로고    scopus 로고
    • Cricoid pressure: Can protective force be sustained?
    • Meek T, Vincent A, Duggan JE. Cricoid pressure: can protective force be sustained? Br. J. Anaesth. 1998 80 : 672 4.
    • (1998) Br. J. Anaesth. , vol.80 , pp. 672-4
    • Meek, T.1    Vincent, A.2    Duggan, J.E.3
  • 25
    • 0001840210 scopus 로고    scopus 로고
    • Lower oesophageal sphincter pressure during application of cricoid pressure in conscious volunteers
    • Tournadre JP, Chassard D, Berrada K, Bouletrau P. Lower oesophageal sphincter pressure during application of cricoid pressure in conscious volunteers. Br. J. Anaesth. 1996 76 : 15 16.
    • (1996) Br. J. Anaesth. , vol.76 , pp. 15-16
    • Tournadre, J.P.1    Chassard, D.2    Berrada, K.3    Bouletrau, P.4
  • 27
    • 0014723873 scopus 로고
    • Prevention of rise in intragastric pressure due to suxamethonium fasciculations by prior dose of d-tubocurarine
    • La Cour D. Prevention of rise in intragastric pressure due to suxamethonium fasciculations by prior dose of d-tubocurarine. Atca Anaesthesiol. Scand. 1970 14 : 5 15.
    • (1970) Atca Anaesthesiol. Scand. , vol.14 , pp. 5-15
    • La Cour, D.1
  • 28
    • 34250328567 scopus 로고    scopus 로고
    • Basic airway management and decision making
    • In: Roberts, J.R., Hedges, J.R. (eds). Philadelphia: Saunders
    • Vrocher D, Hopson LR. Basic airway management and decision making. In : Roberts JR, Hedges JR (eds). Clinical Procedures in Emergency Medicine. Philadelphia : Saunders, 2004 53 68.
    • (2004) Clinical Procedures in Emergency Medicine. , pp. 53-68
    • Vrocher, D.1    Hopson, L.R.2
  • 30
    • 0022551437 scopus 로고
    • The cricoid yoke - A device for providing consistent and reproducible cricoid pressure
    • Lawes EG, Duncan PW, Bland B, Gemmel L, Downing JW. The cricoid yoke - a device for providing consistent and reproducible cricoid pressure. Br. J. Anaesth. 1986 58 : 925 31.
    • (1986) Br. J. Anaesth. , vol.58 , pp. 925-31
    • Lawes, E.G.1    Duncan, P.W.2    Bland, B.3    Gemmel, L.4    Downing, J.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.