메뉴 건너뛰기




Volumn 17, Issue 7, 2007, Pages 613-615

Role of the Jackson Rees T-piece in pediatric anesthesia

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA; ANESTHESIST; ASSISTED VENTILATION; BREATHING; DEVICE; EDITORIAL; HUMAN; LUNG VENTILATION; PATIENT COMPLIANCE; PEDIATRIC ANESTHESIA; POLLUTION; PRIORITY JOURNAL; TRAINING;

EID: 34250317013     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2007.02252.x     Document Type: Editorial
Times cited : (6)

References (20)
  • 1
    • 0002488083 scopus 로고
    • Anaesthesia in the newborn
    • Jackson Rees G. Anaesthesia in the newborn. BMJ 1950 2 : 1419 1422.
    • (1950) BMJ , vol.2 , pp. 1419-1422
    • Jackson Rees, G.1
  • 2
    • 0032981474 scopus 로고    scopus 로고
    • Low flow anaesthesia in infants and children
    • Meakin G. Low flow anaesthesia in infants and children. Br J Anaesth 1999 83 : 50 57.
    • (1999) Br J Anaesth , vol.83 , pp. 50-57
    • Meakin, G.1
  • 3
    • 34250374871 scopus 로고    scopus 로고
    • Should the use of modified Jackson Rees T-piece breathing system be abandoned in preschool children?
    • in press).
    • von Ungern-Sternberg BS, Soudan S, Regli A, et al. Should the use of modified Jackson Rees T-piece breathing system be abandoned in preschool children? Pediatr Anesth 2007 (in press).
    • (2007) Pediatr Anesth
    • Von Ungern-Sternberg, B.S.1    Soudan, S.2    Regli, A.3
  • 5
    • 0029885309 scopus 로고    scopus 로고
    • Sevoflurane-nitrous oxide or halothane-nitrous oxide for paediatric bronchoscopy and gastroscopy
    • Meretoja OA, Taivainen T, Raiha L, et al. Sevoflurane-nitrous oxide or halothane-nitrous oxide for paediatric bronchoscopy and gastroscopy. Br J Anaesth 1996 76 : 767 771.
    • (1996) Br J Anaesth , vol.76 , pp. 767-771
    • Meretoja, O.A.1    Taivainen, T.2    Raiha, L.3
  • 6
    • 0009153497 scopus 로고    scopus 로고
    • Anesthesia equipment for pediatrics
    • In: Gregory, G.A. ed. New York: Churchill Livingstone
    • Fisher DM. Anesthesia equipment for pediatrics. In : Gregory GA ed. Pediatric Anesthesia. 4th edn. New York : Churchill Livingstone, 2002 : 191 216.
    • (2002) Pediatric Anesthesia. 4th Edn. , pp. 191-216
    • Fisher, D.M.1
  • 7
    • 0021063258 scopus 로고
    • Wasted ventilation measured in vitro with eight anesthetic circuits with and without inline humidification
    • Coté CJ, Petkau AJ, Ryan JF, et al. Wasted ventilation measured in vitro with eight anesthetic circuits with and without inline humidification. Anesthesiology 1983 59 : 442 446.
    • (1983) Anesthesiology , vol.59 , pp. 442-446
    • Coté, C.J.1    Petkau, A.J.2    Ryan, J.F.3
  • 8
    • 9244227068 scopus 로고    scopus 로고
    • Volume-controlled ventilation is made possible in infants by using compliant breathing circuits with large compression volume
    • Badgwell JM, Swan J, Foster AC. Volume-controlled ventilation is made possible in infants by using compliant breathing circuits with large compression volume. Anesth Analg 1996 82 : 719 723.
    • (1996) Anesth Analg , vol.82 , pp. 719-723
    • Badgwell, J.M.1    Swan, J.2    Foster, A.C.3
  • 9
    • 0031931371 scopus 로고    scopus 로고
    • The effect of circuit compliance on delivered ventilation with use of an adult circle system for time cycled volume controlled ventilation using an infant lung model
    • Stevenson GW, Tobin MJ, Horn BJ, et al. The effect of circuit compliance on delivered ventilation with use of an adult circle system for time cycled volume controlled ventilation using an infant lung model. Paediatr Anaesth 1998 8 : 139 144.
    • (1998) Paediatr Anaesth , vol.8 , pp. 139-144
    • Stevenson, G.W.1    Tobin, M.J.2    Horn, B.J.3
  • 10
    • 0015394057 scopus 로고
    • A new and highly efficient circuit for paediatric anaesthesia
    • Carden E, Nelson D. A new and highly efficient circuit for paediatric anaesthesia. Can Anaesth Soc J 1972 19 : 572 582.
    • (1972) Can Anaesth Soc J , vol.19 , pp. 572-582
    • Carden, E.1    Nelson, D.2
  • 11
    • 0026871493 scopus 로고
    • "the educated hand"
    • Heneghan C. "The educated hand". Anesthesiolgy 1992 76 : 1063.
    • (1992) Anesthesiolgy , vol.76 , pp. 1063
    • Heneghan, C.1
  • 12
    • 0033973892 scopus 로고    scopus 로고
    • Comparison of the NAD 600 and Servo 900C ventilators in an infant lung model
    • Stayer SA, Bent ST, Campos CJ et al. Comparison of the NAD 600 and Servo 900C ventilators in an infant lung model. Anesth Analg 2000 90 : 315 321.
    • (2000) Anesth Analg , vol.90 , pp. 315-321
    • Stayer, S.A.1    Bent, S.T.2    Campos, C.J.3
  • 13
    • 84994916125 scopus 로고
    • The "educated hand" in paediatric anaesthesia - Does it exist?
    • Tan SS-W, Sury MRJ, Hatch DJ. The "educated hand" in paediatric anaesthesia - does it exist? Paediatr Anaesth 1993 3 : 291 295.
    • (1993) Paediatr Anaesth , vol.3 , pp. 291-295
    • Ss-W, T.1    Sury, M.R.J.2    Hatch, D.J.3
  • 14
    • 0034949137 scopus 로고    scopus 로고
    • Can pediatric anesthesiologists detect an occluded tracheal tube in neonates?
    • Schily M, Koumoukelis H, Lerman J et al. Can pediatric anesthesiologists detect an occluded tracheal tube in neonates? Anesth Analg 2001 93 : 66 70.
    • (2001) Anesth Analg , vol.93 , pp. 66-70
    • Schily, M.1    Koumoukelis, H.2    Lerman, J.3
  • 15
    • 0029286550 scopus 로고
    • Assessment of pulmonary mechanics and gastric inflation pressure during mask ventilation
    • Weiler N, Heinrichs W, Dick W. Assessment of pulmonary mechanics and gastric inflation pressure during mask ventilation. Prehospital & Disaster Medicine 1995 10 : 101 105.
    • (1995) Prehospital & Disaster Medicine , vol.10 , pp. 101-105
    • Weiler, N.1    Heinrichs, W.2    Dick, W.3
  • 16
    • 0031881385 scopus 로고    scopus 로고
    • Severe ventilatory compromise due to gastric distention during pediatric cardiopulmonary resuscitation
    • Berg MD, Idris AH, Berg RA. Severe ventilatory compromise due to gastric distention during pediatric cardiopulmonary resuscitation. Resuscitation 1998 36 : 71 73.
    • (1998) Resuscitation , vol.36 , pp. 71-73
    • Berg, M.D.1    Idris, A.H.2    Berg, R.A.3
  • 17
    • 0000929719 scopus 로고
    • Problems in ventilation: A panel discussion
    • Cullen SC, Comroe JH, Brown EB et al. Problems in ventilation: a panel discussion. Anesthesiolgy 1954 15 : 416 135.
    • (1954) Anesthesiolgy , vol.15 , pp. 416-135
    • Cullen, S.C.1    Comroe, J.H.2    Brown, E.B.3
  • 18
    • 0014064285 scopus 로고
    • The educated hand of the anesthesiologist. a study of professional skill
    • Egbert LD, Bisno D. The educated hand of the anesthesiologist. A study of professional skill. Anesth Analg 1967 46 : 195 200.
    • (1967) Anesth Analg , vol.46 , pp. 195-200
    • Egbert, L.D.1    Bisno, D.2
  • 19
    • 0026395222 scopus 로고
    • The "not-so-educated hand" of the pediatric anesthesiologist
    • Steward DJ. The "not-so-educated hand" of the pediatric anesthesiologist. Anesthesiology 1991 75 : 555 556.
    • (1991) Anesthesiology , vol.75 , pp. 555-556
    • Steward, D.J.1
  • 20
    • 0026408536 scopus 로고
    • The "educated hand" Can anesthesiologists assess changes in neonatal pulmonary compliance manually?
    • Spears RS Jr., Yeh A, Fisher DM et al. The "educated hand" Can anesthesiologists assess changes in neonatal pulmonary compliance manually? Anesthesiology 1991 75 : 693 696.
    • (1991) Anesthesiology , vol.75 , pp. 693-696
    • Spears Jr., R.S.1    Yeh, A.2    Fisher, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.