메뉴 건너뛰기




Volumn 19, Issue 3, 2007, Pages 203-206

Frova intubating catheter position can be determined with aspirating oesophageal detection device

Author keywords

Airway; Catheter; Intubation; Oesophageal detector device

Indexed keywords

ADULT; ANALYTICAL EQUIPMENT; ANESTHESIA INDUCTION; ARTICLE; ASPIRATION; CATHETER; CATHETERIZATION; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTIVE SURGERY; ENDOTRACHEAL INTUBATION; ESOPHAGUS; FEMALE; HUMAN; MALE; PRIORITY JOURNAL; RELIABILITY; TIME;

EID: 34250308455     PISSN: 17426731     EISSN: 17426723     Source Type: Journal    
DOI: 10.1111/j.1742-6723.2007.00926.x     Document Type: Article
Times cited : (4)

References (21)
  • 1
    • 0002777916 scopus 로고
    • Death on the table
    • Edwards G. Death on the table. Br. J. Anaesth. 1938 15 : 87 103.
    • (1938) Br. J. Anaesth. , vol.15 , pp. 87-103
    • Edwards, G.1
  • 2
    • 0028868095 scopus 로고
    • Death and other complications of emergency airway management in critically ill patients
    • Schwartz DE, Matthay MA, Cohen NH et al. Death and other complications of emergency airway management in critically ill patients. Anaesthesiology 1995 82 : 367 76.
    • (1995) Anaesthesiology , vol.82 , pp. 367-76
    • Schwartz, D.E.1    Matthay, M.A.2    Cohen, N.H.3
  • 3
    • 0033066775 scopus 로고    scopus 로고
    • Complications of emergency intubation with and without paralysis
    • Li J, Murphy-Lavoie H, Bugas C et al. Complications of emergency intubation with and without paralysis. Am. J. Emerg. Med. 1999 12 : 141 3.
    • (1999) Am. J. Emerg. Med. , vol.12 , pp. 141-3
    • Li, J.1    Murphy-Lavoie, H.2    Bugas, C.3
  • 4
    • 3242753402 scopus 로고    scopus 로고
    • Emergency tracheal intubation: Complications associated with repeated laryngoscopic attempts
    • Mort TC. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth. Analg. 2004 99 : 607 13.
    • (2004) Anesth. Analg. , vol.99 , pp. 607-13
    • Mort, T.C.1
  • 5
    • 0024487091 scopus 로고
    • Detection of oesophageal intubation: The cola complication
    • Zbinden S, Schupfer G. Detection of oesophageal intubation: the cola complication. Anaesthesia 1989 44 : 44 81.
    • (1989) Anaesthesia , vol.44 , pp. 44-81
    • Zbinden, S.1    Schupfer, G.2
  • 6
    • 0036284052 scopus 로고    scopus 로고
    • Comparison of three different methods to confirm tracheal tube placement in emergency intubation
    • Grmec S. Comparison of three different methods to confirm tracheal tube placement in emergency intubation. Intensive Care Med. 2002 28 : 701 4.
    • (2002) Intensive Care Med. , vol.28 , pp. 701-4
    • Grmec, S.1
  • 7
    • 0023696973 scopus 로고
    • A method of detecting oesophageal intubation or confirming tracheal intubation
    • Olearly JJ, Pollard BJ, Ryan MJ. A method of detecting oesophageal intubation or confirming tracheal intubation. Anaesth. Intensive Care 1988 16 : 200 301.
    • (1988) Anaesth. Intensive Care , vol.16 , pp. 200-301
    • Olearly, J.J.1    Pollard, B.J.2    Ryan, M.J.3
  • 8
    • 0027248049 scopus 로고
    • The esophageal detector device. Does it work?
    • Zaleski L, Abello D, Gold MI. The esophageal detector device. Does it work? Anaesthesiology 1993 79 : 244 7.
    • (1993) Anaesthesiology , vol.79 , pp. 244-7
    • Zaleski, L.1    Abello, D.2    Gold, M.I.3
  • 9
    • 0026321843 scopus 로고
    • The oesophageal detector device
    • Wee M. The oesophageal detector device. Anaesthesiae 1991 46 : 1086 7.
    • (1991) Anaesthesiae , vol.46 , pp. 1086-7
    • Wee, M.1
  • 10
    • 0036915501 scopus 로고    scopus 로고
    • The tracheal detecting-bulb: A new device to distinguish tracheal from esophageal intubation
    • Tong YL, Sun M, Tang WH, Xia JY. The tracheal detecting-bulb: a new device to distinguish tracheal from esophageal intubation. Acta Anaesthesiol. Sin. 2002 40 : 159 63.
    • (2002) Acta Anaesthesiol. Sin. , vol.40 , pp. 159-63
    • Tong, Y.L.1    Sun, M.2    Tang, W.H.3    Xia, J.Y.4
  • 11
    • 0002145322 scopus 로고
    • An aid to oral intubation
    • MacIntosch RR. An aid to oral intubation. Br. Med. J. 1949 1 : 28.
    • (1949) Br. Med. J. , vol.1 , pp. 28
    • MacIntosch, R.R.1
  • 12
    • 0023912196 scopus 로고    scopus 로고
    • Successful difficult intubation. Use of the gum elastic bougie
    • Kidd JF, Dyson A, Latto IP. Successful difficult intubation. Use of the gum elastic bougie. Anaesthesia 2002 43 : 437 8.
    • (2002) Anaesthesia , vol.43 , pp. 437-8
    • Kidd, J.F.1    Dyson, A.2    Latto, I.P.3
  • 13
    • 25144505286 scopus 로고    scopus 로고
    • An assessment of a tracheal tube introducer as an endotracheal tube placement confirmation device
    • Bair AE, Laurin EG, Schmitt BJ. An assessment of a tracheal tube introducer as an endotracheal tube placement confirmation device. Am. J. Emerg. Med. 2005 23 : 754 8.
    • (2005) Am. J. Emerg. Med. , vol.23 , pp. 754-8
    • Bair, A.E.1    Laurin, E.G.2    Schmitt, B.J.3
  • 14
    • 7444263974 scopus 로고    scopus 로고
    • Use of the endotracheal bougie introducer for difficult intubations
    • Phelan MP. Use of the endotracheal bougie introducer for difficult intubations. Am. J. Emerg. Med. 2004 22 : 479 82.
    • (2004) Am. J. Emerg. Med. , vol.22 , pp. 479-82
    • Phelan, M.P.1
  • 15
    • 22444449167 scopus 로고    scopus 로고
    • Use gum elastic bougie for prehospital difficult intubation
    • Jabre P, Combes X, Leroux B et al. Use gum elastic bougie for prehospital difficult intubation. Am. Emerg. Med. 2005 24 : 552 5.
    • (2005) Am. Emerg. Med. , vol.24 , pp. 552-5
    • Jabre, P.1    Combes, X.2    Leroux, B.3
  • 16
    • 2142703644 scopus 로고    scopus 로고
    • Unanticipated difficult airway in anaesthetized patients: Prospective validation of a management algorithm
    • Combes X, Le Roux B, Suen P et al. Unanticipated difficult airway in anaesthetized patients: prospective validation of a management algorithm. Anesthesiology 2004 100 : 1146 50.
    • (2004) Anesthesiology , vol.100 , pp. 1146-50
    • Combes, X.1    Le Roux, B.2    Suen, P.3
  • 17
    • 0034113386 scopus 로고    scopus 로고
    • Confirmation of correct endotracheal tube placement
    • Black JJ, Skinner DV. Confirmation of correct endotracheal tube placement. J. Accid. Emerg. Med. 2000 17 : 74 5.
    • (2000) J. Accid. Emerg. Med. , vol.17 , pp. 74-5
    • Black, J.J.1    Skinner, D.V.2
  • 19
    • 21644475473 scopus 로고    scopus 로고
    • Continuous end-tidal carbon dioxide monitoring for confirmation of endotracheal tube placement is neither widely available nor consistently applied by emergency physicians
    • Deiorio NM. Continuous end-tidal carbon dioxide monitoring for confirmation of endotracheal tube placement is neither widely available nor consistently applied by emergency physicians. Emerg. Med. J. 2005 22 : 490 3.
    • (2005) Emerg. Med. J. , vol.22 , pp. 490-3
    • Deiorio, N.M.1
  • 20
    • 0030804065 scopus 로고    scopus 로고
    • Oesophageal detector device
    • article 6. Available from URL: [Accessed August 2006].
    • Haridas RP. Oesophageal detector device. Updat. Anaes. 1997 7, article 6. Available from URL: http://www.nda.ox.ac.uk.wfsa/ [Accessed August 2006].
    • (1997) Updat. Anaes. , vol.7
    • Haridas, R.P.1
  • 21
    • 0031007604 scopus 로고    scopus 로고
    • Out-of-hospital experience with the syringe oesophageal detector device
    • Pelucio M, Halligan L, Dhindsa H. Out-of-hospital experience with the syringe oesophageal detector device. Acad. Emerg. Med. 1997 4 : 563 8.
    • (1997) Acad. Emerg. Med. , vol.4 , pp. 563-8
    • Pelucio, M.1    Halligan, L.2    Dhindsa, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.