메뉴 건너뛰기




Volumn 22, Issue 4, 2007, Pages 213-220

Assessment of reliable quantification of the dynamics of cerebrospinal fluid by magnetic resonance imaging in idiopathic normal pressure hydrocephalus;Valoración de la cuantificación fiable de la dinámica del líquido cefalorraquídeo en el acueducto de Silvio mediante resonancia magnética en la hidrocefalia normopresiva idiopática

Author keywords

Flow quantification; Magnetic resonance; Normal pressure hydrocephalus; Phase contrast

Indexed keywords

ADULT; ARTICLE; BRAIN AQUEDUCT; CEREBROSPINAL FLUID; CLINICAL ARTICLE; COMORBIDITY; CONTROLLED STUDY; FEMALE; HEART STROKE VOLUME; HUMAN; IDIOPATHIC DISEASE; MALE; NORMOTENSIVE HYDROCEPHALUS; NUCLEAR MAGNETIC RESONANCE IMAGING; SYSTOLIC BLOOD PRESSURE;

EID: 34250308084     PISSN: 02134853     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (28)
  • 1
    • 0013785967 scopus 로고
    • The special clinical problem of symptomatic hydrocephalus with normal cerebrospinal fluid pressure. Observations on cerebrospinal fluid pressure hydrodynamics
    • Hakim S, Adams RD. The special clinical problem of symptomatic hydrocephalus with normal cerebrospinal fluid pressure. Observations on cerebrospinal fluid pressure hydrodynamics. J Neurol Sci 1965;2:307-27.
    • (1965) J Neurol Sci , vol.2 , pp. 307-327
    • Hakim, S.1    Adams, R.D.2
  • 2
    • 0035161907 scopus 로고    scopus 로고
    • Actualizaciones en el diagnóstic y tratamiento de la hidrocefalia normotensiva (hidrocefalia crónica del adulto)
    • Poca MA, Sahuquillo J, Mataro M. Actualizaciones en el diagnóstic y tratamiento de la hidrocefalia normotensiva (hidrocefalia crónica del adulto). Neurología 2001;16:353-69.
    • (2001) Neurología , vol.16 , pp. 353-369
    • Poca, M.A.1    Sahuquillo, J.2    Mataro, M.3
  • 3
    • 33745280557 scopus 로고    scopus 로고
    • Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of sylvius
    • Flórez YN, Moratal D, Forner J, Martí-Bonmatí L, Arana E, Guajardo-Hernández U, et al. Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of sylvius. Magn Reson Mater Phy 2006; 19:78-87.
    • (2006) Magn Reson Mater Phy , vol.19 , pp. 78-87
    • Flórez, Y.N.1    Moratal, D.2    Forner, J.3    Martí-Bonmatí, L.4    Arana, E.5    Guajardo-Hernández, U.6
  • 4
    • 0030028170 scopus 로고    scopus 로고
    • Normal-pressure hydrocephalus: Evaluation with cerebrospinal fluid flow measurements at MR imaging
    • Bradley WG, Scalzo D, Queralt J, Nitz WN, Atkinson DJ, Wong P. Normal-pressure hydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR imaging. Radiology 1996;198: 523-9.
    • (1996) Radiology , vol.198 , pp. 523-529
    • Bradley, W.G.1    Scalzo, D.2    Queralt, J.3    Nitz, W.N.4    Atkinson, D.J.5    Wong, P.6
  • 5
    • 0026690346 scopus 로고
    • Flow dynamics of cerebrospinal-fluid - assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating
    • Nitz WR, Bradley WG, Watanabe AS, Lee RR, Burgoyne B, Osullivan RM, et al. Flow dynamics of cerebrospinal-fluid - assessment with phase-contrast velocity MR imaging performed with retrospective cardiac gating. Radiology 1992;183:395-405.
    • (1992) Radiology , vol.183 , pp. 395-405
    • Nitz, W.R.1    Bradley, W.G.2    Watanabe, A.S.3    Lee, R.R.4    Burgoyne, B.5    Osullivan, R.M.6
  • 6
    • 0032836602 scopus 로고    scopus 로고
    • Quantitative assessment of cerebrospinal fluid hydrodynamics using a phase-contrast cine MR image in hydrocephalus
    • Kim DS, Choi JU, Huh R, Yun PH, Kim DI. Quantitative assessment of cerebrospinal fluid hydrodynamics using a phase-contrast cine MR image in hydrocephalus. Childs Nerv Syst 1999; 15:461-7.
    • (1999) Childs Nerv Syst , vol.15 , pp. 461-467
    • Kim, D.S.1    Choi, J.U.2    Huh, R.3    Yun, P.H.4    Kim, D.I.5
  • 7
    • 0027617090 scopus 로고
    • Quantitative measurement of normal and hydrocephalic CSF flow using phase-contrast cine MR imaging
    • Katayama S, Asari S, Ohmoto T. Quantitative measurement of normal and hydrocephalic CSF flow using phase-contrast cine MR imaging. Acta Med Okayama 1993;47:157-68.
    • (1993) Acta Med Okayama , vol.47 , pp. 157-168
    • Katayama, S.1    Asari, S.2    Ohmoto, T.3
  • 8
    • 0028388950 scopus 로고
    • Phase-contrast cine MR-imaging of normal aqueductal CSF flow - effect of aging and relation to CSF void on modulus MR
    • Barkhof E, Kouwenhoven M, Scheltens P, Sprenger M, Algra P, Valk J. Phase-contrast cine MR-imaging of normal aqueductal CSF flow - effect of aging and relation to CSF void on modulus MR. Acta Radiol 1994;35:123-30.
    • (1994) Acta Radiol , vol.35 , pp. 123-130
    • Barkhof, E.1    Kouwenhoven, M.2    Scheltens, P.3    Sprenger, M.4    Algra, P.5    Valk, J.6
  • 9
    • 0029351712 scopus 로고
    • Flow quantification and analysis methods
    • Pelc NJ. Flow quantification and analysis methods. Magn Reson Imaging Clin N Am 1995;3:413-24.
    • (1995) Magn Reson Imaging Clin N Am , vol.3 , pp. 413-424
    • Pelc, N.J.1
  • 10
    • 85010255291 scopus 로고    scopus 로고
    • CSF flow quantification of the cerebral aqueduct in normal volunteers using phase contrast cine MR imaging
    • Lee JH, Lee HK, Kim JK, Kim HJ, Park JK, Choi CG. CSF flow quantification of the cerebral aqueduct in normal volunteers using phase contrast cine MR imaging. Korean J Radio 2004;15: 81-6.
    • (2004) Korean J Radio , vol.15 , pp. 81-86
    • Lee, J.H.1    Lee, H.K.2    Kim, J.K.3    Kim, H.J.4    Park, J.K.5    Choi, C.G.6
  • 11
    • 0036523920 scopus 로고    scopus 로고
    • Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: Technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus
    • Luetmer PH, Huston J, Friedman JA, Dixon GR, Petersen RC, Jack CR, et al. Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus. Neurosurgery 2002;50: 534-42.
    • (2002) Neurosurgery , vol.50 , pp. 534-542
    • Luetmer, P.H.1    Huston, J.2    Friedman, J.A.3    Dixon, G.R.4    Petersen, R.C.5    Jack, C.R.6
  • 12
    • 0026915854 scopus 로고
    • Magnetic resonance imaging in the evaluation of cerebrospinal fluid flow abnormalities
    • Bradley WG. Magnetic resonance imaging in the evaluation of cerebrospinal fluid flow abnormalities. Magn Reson Q 1992;8: 169-96.
    • (1992) Magn Reson Q , vol.8 , pp. 169-196
    • Bradley, W.G.1
  • 13
    • 0022457502 scopus 로고
    • Flowing cerebrospinal-fluid in normal and hydrocephalic states - appearance on MR images
    • Bradley WG, Kortman KE, Burgoyne B. Flowing cerebrospinal-fluid in normal and hydrocephalic states - appearance on MR images. Radiology 1986;159:611-6.
    • (1986) Radiology , vol.159 , pp. 611-616
    • Bradley, W.G.1    Kortman, K.E.2    Burgoyne, B.3
  • 14
    • 0026485075 scopus 로고
    • Brain motion-measurement with phase-contrast MR imaging
    • Enzmann DR, Pelc NJ. Brain motion-measurement with phase-contrast MR imaging. Radiology 1992;185:653-60.
    • (1992) Radiology , vol.185 , pp. 653-660
    • Enzmann, D.R.1    Pelc, N.J.2
  • 15
    • 0028888747 scopus 로고
    • Analysis of cerebrospinal-fluid flow wave-forms with gated phase-contrast MR velocity-measurements
    • Bhadelia RA, Bogdan AR, Wolpert SM. Analysis of cerebrospinal-fluid flow wave-forms with gated phase-contrast MR velocity-measurements. Am J Neuroradiol 1995;16:389-400.
    • (1995) Am J Neuroradiol , vol.16 , pp. 389-400
    • Bhadelia, R.A.1    Bogdan, A.R.2    Wolpert, S.M.3
  • 16
    • 0036597341 scopus 로고    scopus 로고
    • Elimination of errors caused by first-order aliasing in velocity encoded cine-MR measurements of postoperative jets after aortic coarctation: In vitro and in vivo validation
    • Henk CB, Grampp S, Koller J, Schoder M, Frank H, Klaar U, et al. Elimination of errors caused by first-order aliasing in velocity encoded cine-MR measurements of postoperative jets after aortic coarctation: in vitro and in vivo validation. Eur Radiol 2002;12:1523-31.
    • (2002) Eur Radiol , vol.12 , pp. 1523-1531
    • Henk, C.B.1    Grampp, S.2    Koller, J.3    Schoder, M.4    Frank, H.5    Klaar, U.6
  • 17
    • 0036134296 scopus 로고    scopus 로고
    • Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements
    • Greil G, Geva T, Maier SE, Powell AJ. Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements. J Magn Reson Imaging 2002;15:47-54.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 47-54
    • Greil, G.1    Geva, T.2    Maier, S.E.3    Powell, A.J.4
  • 18
    • 0027692590 scopus 로고
    • Frequency-response of retrospectively gated phase-contrast MR-imaging - effect of interpolation
    • Frayne R, Rutt BK. Frequency-response of retrospectively gated phase-contrast MR-imaging - effect of interpolation. J Magn Reson Imaging 1993;3:907-17.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 907-917
    • Frayne, R.1    Rutt, B.K.2
  • 19
    • 0031828994 scopus 로고    scopus 로고
    • MR quantification of flow in abdominal vessels
    • Debatin JF. MR quantification of flow in abdominal vessels. Abdom Imaging 1998;23:485-95.
    • (1998) Abdom Imaging , vol.23 , pp. 485-495
    • Debatin, J.F.1
  • 22
    • 0025961729 scopus 로고
    • Association of deep white matter infarction with chronic communicating hydrocephalus: Implications regarding the possible origin of normal-pressure hydrocephalus
    • Bradley WG, Whitteemore AR, Watanabe AS, Davis SJ, Teresi LM, Homyak M. Association of deep white matter infarction with chronic communicating hydrocephalus: implications regarding the possible origin of normal-pressure hydrocephalus. Am J Neuroradioloy 1991;12:31-9.
    • (1991) Am J Neuroradioloy , vol.12 , pp. 31-39
    • Bradley, W.G.1    Whitteemore, A.R.2    Watanabe, A.S.3    Davis, S.J.4    Teresi, L.M.5    Homyak, M.6
  • 23
    • 0033772006 scopus 로고    scopus 로고
    • Vascular compliance in normal pressure hydrocephalus
    • Bateman GA. Vascular compliance in normal pressure hydrocephalus. Am J Neuroradiology 2000;21:1574-85.
    • (2000) Am J Neuroradiology , vol.21 , pp. 1574-1585
    • Bateman, G.A.1
  • 24
    • 0000295689 scopus 로고    scopus 로고
    • Velocity and volume flow rate measurements using phase contrast magnetic resonance imaging
    • Korosec FR, Turski PA. Velocity and volume flow rate measurements using phase contrast magnetic resonance imaging. Int J Neuroradiol 1997;3:203-318.
    • (1997) Int J Neuroradiol , vol.3 , pp. 203-318
    • Korosec, F.R.1    Turski, P.A.2
  • 26
    • 0030028170 scopus 로고    scopus 로고
    • Normal-pressure hydrocephalus: Evaluation with cerebrospinal fluid flow measurements at MR Imaging
    • Bradley WG, Scalzo D, Queralt J, Nitz WN, Atkinson DJ, Wong P. Normal-pressure hydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR Imaging. Radiology 1996;198: 523-9.
    • (1996) Radiology , vol.198 , pp. 523-529
    • Bradley, W.G.1    Scalzo, D.2    Queralt, J.3    Nitz, W.N.4    Atkinson, D.J.5    Wong, P.6
  • 27
    • 0035960650 scopus 로고    scopus 로고
    • The cerebrospinal fluid production rate is reduced in dementia of Alzheimer's type
    • Silverberg GD, Heit G, Huhn S. The cerebrospinal fluid production rate is reduced in dementia of Alzheimer's type. Neurology 2001;57:1763-6.
    • (2001) Neurology , vol.57 , pp. 1763-1766
    • Silverberg, G.D.1    Heit, G.2    Huhn, S.3
  • 28
    • 7044269532 scopus 로고    scopus 로고
    • Supratentorial cerebrospinal fluid production rate in healthy adults: Quantification with two-dimensional cine phase-contrast MR imaging with high temporal and spatial resolution
    • Huang TY, Chung HW, Chen MY, Giiang LH, Chin SC, Lee CS, et al. Supratentorial cerebrospinal fluid production rate in healthy adults: quantification with two-dimensional cine phase-contrast MR imaging with high temporal and spatial resolution. Radiology 2004;233:603-8.
    • (2004) Radiology , vol.233 , pp. 603-608
    • Huang, T.Y.1    Chung, H.W.2    Chen, M.Y.3    Giiang, L.H.4    Chin, S.C.5    Lee, C.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.