Volumn 20, Issue 3, 2007, Pages 207-217

Dust and electrostatic hazards, could we improve the current standards?

Author keywords

Charge decay time; Icing sugar; Magnesium stearate; Static electricity; Volume resistivity

Indexed keywords

DUST; STANDARDS; STATIC ELECTRICITY; THERMAL EFFECTS;

EID: 34250215953     PISSN: 09504230     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jlp.2007.03.006     Document Type: Article
Times cited : (14)

References (26)
  • 1
    • 0017960439 scopus 로고
    • Electrical conduction and polarisation phenomena in polymeric dielectrics at low fields
    • Adamec V., and Calderwood J.H. Electrical conduction and polarisation phenomena in polymeric dielectrics at low fields. Journal Physics D: Applied Physics 11 (1978) 781-800
    • (1978) Journal Physics D: Applied Physics , vol.11 , pp. 781-800
    • Adamec, V.1    Calderwood, J.H.2
  • 2
    • 34250198350 scopus 로고    scopus 로고
    • ASTM D257-99. (2005). Standard test methods for DC resistance or conductance of insulating materials.
  • 3
    • 34250213321 scopus 로고    scopus 로고
    • Barois-Cazenave, A., Falk, V., Leclerc, D., Tondeur, D., & Tranchant, J. F. (1999). Behaviour of cosmetic powder mixtures under pressure. Fine Powder Processing, September 20-22. USA: PennState University.
  • 5
    • 2842577419 scopus 로고    scopus 로고
    • Beck, H., & Jeske, A. (1996). Berichte über Staubexplosionen-Einzelereignisse und documentation. VDI Berichte no. 1272, VDI Verlag, pp. 365-387.
  • 6
    • 34250208142 scopus 로고    scopus 로고
    • BS-5958: Part 1. (1991). Control of undesirable static electricity. Part 1: General considerations. British Standards Institution.
  • 7
    • 34250195442 scopus 로고    scopus 로고
    • BS-7506: Part 2. (1996). Methods for measurement in electrostatics. Guide to basic electrostatics. British Standards Institution.
  • 8
    • 26444571355 scopus 로고    scopus 로고
    • Influence of the size distribution and concentration on wood dust explosion: experiments and reaction modelling
    • Callé S., Klaba L., Thomas D., Perrin L., and Dufaud O. Influence of the size distribution and concentration on wood dust explosion: experiments and reaction modelling. Powder Technology 157 (2005) 144-148
    • (2005) Powder Technology , vol.157 , pp. 144-148
    • Callé, S.1    Klaba, L.2    Thomas, D.3    Perrin, L.4    Dufaud, O.5
  • 9
    • 3242736408 scopus 로고    scopus 로고
    • Comments on methods for charge decay measurement
    • Chubb J. Comments on methods for charge decay measurement. Journal of Electrostatics 62 (2004) 73-80
    • (2004) Journal of Electrostatics , vol.62 , pp. 73-80
    • Chubb, J.1
  • 11
    • 34250212233 scopus 로고    scopus 로고
    • Electrostatic Discharge Association. (1994). Electrostatic discharge control handbook. Rome, NY: Electrostatic Discharge Association.
  • 13
    • 0242288885 scopus 로고    scopus 로고
    • Ignition hazard due to static electricity in particulate processes
    • Glor M. Ignition hazard due to static electricity in particulate processes. Powder Technology 135-136 (2003) 223-233
    • (2003) Powder Technology , vol.135-136 , pp. 223-233
    • Glor, M.1
  • 14
    • 18244401117 scopus 로고    scopus 로고
    • Electrostatic ignition hazards in the process industry
    • Glor M. Electrostatic ignition hazards in the process industry. Journal of Electrostatics 63 (2005) 447-453
    • (2005) Journal of Electrostatics , vol.63 , pp. 447-453
    • Glor, M.1
  • 15
    • 34250168389 scopus 로고    scopus 로고
    • IEC standard 1241-2-2. (1993). Method for determining the electrical resistivity of dust in layers. International Electrotechnical Commission.
  • 16
    • 34250204967 scopus 로고    scopus 로고
    • IEC standard 1241-2-1. (1994). Electrical apparatus for use in the presence of combustible dust. Part 2: Test methods section 1: Methods for determining the minimum ignition temperatures of dust. International Electrotechnical Commission.
  • 17
    • 34250220387 scopus 로고    scopus 로고
    • IEC standard 1241-2-3. (1994). Method for determining minimum ignition energy of dust/air mixtures. International Electrotechnical Commission.
  • 18
    • 34250206037 scopus 로고    scopus 로고
    • IEC standard 61340-2-1 (2002). Measurement methods-Ability of materials and products to dissipate static electric charge. International Electrotechnical Commission.
  • 20
    • 34250195843 scopus 로고    scopus 로고
    • MIL-STD-1686 (1995). Electrostatic discharge control program for protection of electrical and electronic parts, assemblies and equipment (excluding electrically initiated explosive devices). US Department of Defense Standard Practice.
  • 21
    • 0030110101 scopus 로고    scopus 로고
    • Sorption and diffusion of solvent vapours in poly(vinylalcohol) membranes of different crystallinity degrees
    • Perrin L., Nguyen Q.T., Clement R., and Neel J. Sorption and diffusion of solvent vapours in poly(vinylalcohol) membranes of different crystallinity degrees. Polymer International 39 (1996) 251-260
    • (1996) Polymer International , vol.39 , pp. 251-260
    • Perrin, L.1    Nguyen, Q.T.2    Clement, R.3    Neel, J.4
  • 22
    • 34250160994 scopus 로고    scopus 로고
    • Schofield, C., & Abbott, J. A. (1988). Guide to dust explosion prevention and protection. Part 2: Ignition prevention, containment, inerting, suppression and isolation. Rugby, the Institution of Chemical Engineers.
  • 26
    • 34250194708 scopus 로고
    • Static electricity as a hazard in industry
    • Van Laar G.F.M. Static electricity as a hazard in industry. Journal de Physique III France 1 (1991) 1377-1387
    • (1991) Journal de Physique III France , vol.1 , pp. 1377-1387
    • Van Laar, G.F.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.