메뉴 건너뛰기




Volumn 31, Issue 9, 2007, Pages 6-10

Selection of feedback signal for power system damping controller based on wide area measurements

Author keywords

Dominant mode ratio; Input signal; Low frequency oscillation; Modulation control; Prony analysis; Wide area damping control

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; CONTROL EQUIPMENT; DAMPING; EIGENVALUES AND EIGENFUNCTIONS; ELECTRIC VARIABLES MEASUREMENT; FEEDBACK; LINEAR SYSTEMS; MODULATION; OSCILLATORS (ELECTRONIC); SIGNAL PROCESSING; TIME DOMAIN ANALYSIS;

EID: 34250018248     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (43)

References (11)
  • 1
    • 21844435719 scopus 로고    scopus 로고
    • The impact of weak interconnection of bulk power grids to damping and dynamic stability of power systems
    • YU Yixin, LI Peng. The impact of weak interconnection of bulk power grids to damping and dynamic stability of power systems. Proceedings of the CSEE, 2005, 25 (11): 6-11.
    • (2005) Proceedings of the CSEE , vol.25 , Issue.11 , pp. 6-11
    • Yu, Y.1    Li, P.2
  • 2
    • 15044343463 scopus 로고    scopus 로고
    • Overview of power system stability analysis and wide area control in consideration of time delay
    • JIANG Quanyuan, ZOU Zhenyu, CAO Yijia, et al. Overview of power system stability analysis and wide area control in consideration of time delay. Automation of Electric Power Systems, 2005, 29 (3): 1-7.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.3 , pp. 1-7
    • Jiang, Q.1    Zou, Z.2    Cao, Y.3
  • 3
    • 1942507510 scopus 로고    scopus 로고
    • Inter-area damping control of interconnected power systems using wide-area measurements
    • XIE Xiaorong, XIAO Jinyu, TONG Luyuan, et al. Inter-area damping control of interconnected power systems using wide-area measurements. Automation of Electric Power Systems, 2004, 28 (2): 37-40.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.2 , pp. 37-40
    • Xie, X.1    Xiao, J.2    Tong, L.3
  • 4
    • 12444338832 scopus 로고    scopus 로고
    • Power systems wide-area damping control based on online system identification
    • XIAO Jinyu, XIE Xiaorong, HU Zhixiang, et al. Power systems wide-area damping control based on online system identification. Automation of Electric Power Systems, 2004, 28 (23): 22-27.
    • (2004) Automation of Electric Power Systems , vol.28 , Issue.23 , pp. 22-27
    • Xiao, J.1    Xie, X.2    Hu, Z.3
  • 5
    • 27144483062 scopus 로고    scopus 로고
    • On selection of supplementary input signals for STATCOM to damp inter-area oscillations in power systems
    • Jun 12-16, 2005, San Francisco, CA, USA. New York, NY, USA: IEEE
    • FARSANGI M M, SONG Y H, LEE K Y. On selection of supplementary input signals for STATCOM to damp inter-area oscillations in power systems// Proceedings of IEEE Power Engineering Society General Meeting: Vol 3, Jun 12-16, 2005, San Francisco, CA, USA. New York, NY, USA: IEEE, 2005: 3068-3073.
    • (2005) Proceedings of IEEE Power Engineering Society General Meeting , vol.3 , pp. 3068-3073
    • Farsangi, M.M.1    Song, Y.H.2    Lee, K.Y.3
  • 6
    • 2542564990 scopus 로고    scopus 로고
    • Choice of FACTS device control inputs for damping inter-area oscillations
    • FARSANGI M M, SONG Y H, LEE K Y. Choice of FACTS device control inputs for damping inter-area oscillations. IEEE Trans on Power Systems, 2004, 19 (2): 1135-1143.
    • (2004) IEEE Trans on Power Systems , vol.19 , Issue.2 , pp. 1135-1143
    • Farsangi, M.M.1    Song, Y.H.2    Lee, K.Y.3
  • 7
    • 0031145425 scopus 로고    scopus 로고
    • Selection of installing locations and feedback signals of FACTS-based stabilizers in multi-machine power systems by reduced-order modal analysis
    • WANG H F, SWIFT F J, LI M. Selection of installing locations and feedback signals of FACTS-based stabilizers in multi-machine power systems by reduced-order modal analysis. IEE Proceedings: Generation, Transmission and Distribution, 1997, 144 (3): 263-269.
    • (1997) IEE Proceedings: Generation, Transmission and Distribution , vol.144 , Issue.3 , pp. 263-269
    • Wang, H.F.1    Swift, F.J.2    Li, M.3
  • 8
    • 0025522085 scopus 로고
    • Determination of suitable locations for power system stabilizers and static VAR compensators for damping electromechanical oscillations in large scale power systems
    • MARTINS N, LIMA L T G. Determination of suitable locations for power system stabilizers and static VAR compensators for damping electromechanical oscillations in large scale power systems. IEEE Trans on Power Systems, 1990, 5 (4): 1455-1469.
    • (1990) IEEE Trans on Power Systems , vol.5 , Issue.4 , pp. 1455-1469
    • Martins, N.1    Lima, L.T.G.2
  • 9
    • 0003393654 scopus 로고    scopus 로고
    • Power system stability and control
    • New York, NY, USA, McGraw-Hill
    • KUNDUR P. Power system stability and control. New York, NY, USA, McGraw-Hill, 2001.
    • (2001)
    • Kundur, P.1
  • 10
    • 27944432181 scopus 로고    scopus 로고
    • Research on coordinated control strategy for inter-area oscillations in China Southern AC/DC power grid
    • MAO Xiaoming, ZHANG Yao, GUAN Lin, et al. Research on coordinated control strategy for inter-area oscillations in China Southern AC/DC power grid. Automation of Electric Power Systems, 2005, 29 (20): 55-59.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.20 , pp. 55-59
    • Mao, X.1    Zhang, Y.2    Guan, L.3
  • 11
    • 0027574763 scopus 로고
    • Utilizing HVDC to damp power oscillations
    • SMED T, ANDERSSON G. Utilizing HVDC to damp power oscillations. IEEE Trans on Power Delivery, 1993, 8 (2): 620-627.
    • (1993) IEEE Trans on Power Delivery , vol.8 , Issue.2 , pp. 620-627
    • Smed, T.1    Andersson, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.