메뉴 건너뛰기




Volumn 44, Issue 1, 2007, Pages 123-136

Dynamometry testing in spinal cord injury

Author keywords

Dynamometry; Functional ability; Grip strength; Handheld dynamometer; Manual muscle test; Muscle contraction; Muscle strength; Rehabilitation; Spinal cord injury; Strength deficit

Indexed keywords

DYNAMOMETRY; FUNCTIONAL ABILITY; GRIP STRENGTH; HANDHELD DYNAMOMETER; MANUAL MUSCLE TEST; MUSCLE CONTRACTION; MUSCLE STRENGTH; SPINAL CORD INJURY; STRENGTH DEFICIT;

EID: 34250015205     PISSN: 07487711     EISSN: 07487711     Source Type: Journal    
DOI: 10.1682/JRRD.2005.11.0172     Document Type: Conference Paper
Times cited : (99)

References (44)
  • 1
    • 0027714858 scopus 로고
    • Relationship of impairment and functional ability to habitual activity and fitness following spinal cord injury
    • Noreau L, Shephard RJ, Simard C, Pare G, Pomerleau P. Relationship of impairment and functional ability to habitual activity and fitness following spinal cord injury. Int J Rehabil Res. 1993;16(4):265-75.
    • (1993) Int J Rehabil Res , vol.16 , Issue.4 , pp. 265-275
    • Noreau, L.1    Shephard, R.J.2    Simard, C.3    Pare, G.4    Pomerleau, P.5
  • 3
    • 0026553347 scopus 로고
    • Physiological adaptations to velocity-controlled resistance training
    • Bell GJ, Wenger HA. Physiological adaptations to velocity-controlled resistance training. Sports Med. 1992;13(4):234-44.
    • (1992) Sports Med , vol.13 , Issue.4 , pp. 234-244
    • Bell, G.J.1    Wenger, H.A.2
  • 4
    • 0025170129 scopus 로고
    • Make versus break tests for measuring elbow flexor muscle force with a hand-held dynamometer in patients with stroke
    • Bohannon RW. Make versus break tests for measuring elbow flexor muscle force with a hand-held dynamometer in patients with stroke. Physiother Can. 1990;42:247-51.
    • (1990) Physiother Can , vol.42 , pp. 247-251
    • Bohannon, R.W.1
  • 5
    • 0028137854 scopus 로고
    • A comparison of make and break tests using a hand-held dynamometer and the Kin-Com
    • Stratford PW, Balsor BE. A comparison of make and break tests using a hand-held dynamometer and the Kin-Com. J Orthop Sports Phys Ther. 1994;19(1):28-32.
    • (1994) J Orthop Sports Phys Ther , vol.19 , Issue.1 , pp. 28-32
    • Stratford, P.W.1    Balsor, B.E.2
  • 6
    • 0023863061 scopus 로고
    • Make tests and break tests of elbow flexor muscle strength
    • Bohannon RW. Make tests and break tests of elbow flexor muscle strength. Phys Ther. 1988;68(2):193-94.
    • (1988) Phys Ther , vol.68 , Issue.2 , pp. 193-194
    • Bohannon, R.W.1
  • 8
    • 11144239942 scopus 로고    scopus 로고
    • Hand-held dynamometry in persons with tetraplegia: Comparison of make- versus break-testing techniques
    • Burns SP, Breuninger A, Kaplan C, Marin H. Hand-held dynamometry in persons with tetraplegia: Comparison of make- versus break-testing techniques. Am J Phys Med Rehabil. 2005;84(1):22-29.
    • (2005) Am J Phys Med Rehabil , vol.84 , Issue.1 , pp. 22-29
    • Burns, S.P.1    Breuninger, A.2    Kaplan, C.3    Marin, H.4
  • 9
    • 33644659288 scopus 로고    scopus 로고
    • Marino RJ, Barros T, Biering-Sorensen F, Burns SP, Donovan WH, Graves DE, Haak M, Hudson LM, Priebe MM. ASIA Neurological standards for neurological classification of spinal cord injury. J Spinal Cord Med. 2003;(26 Suppl 1):S50-56.
    • Marino RJ, Barros T, Biering-Sorensen F, Burns SP, Donovan WH, Graves DE, Haak M, Hudson LM, Priebe MM. ASIA Neurological standards for neurological classification of spinal cord injury. J Spinal Cord Med. 2003;(26 Suppl 1):S50-56.
  • 10
    • 0029778193 scopus 로고    scopus 로고
    • Strength post-spinal cord injury: Myometer vs manual muscle test
    • Herbison GJ, Isaac Z, Cohen ME, Ditunno JF Jr. Strength post-spinal cord injury: Myometer vs manual muscle test. Spinal Cord. 1996;34(9):543-48.
    • (1996) Spinal Cord , vol.34 , Issue.9 , pp. 543-548
    • Herbison, G.J.1    Isaac, Z.2    Cohen, M.E.3    Ditunno Jr., J.F.4
  • 11
    • 0028797172 scopus 로고
    • Procedures for setting normal values
    • O'Brien PC, Dyck PJ. Procedures for setting normal values. Neurology. 1995;45(1):17-23.
    • (1995) Neurology , vol.45 , Issue.1 , pp. 17-23
    • O'Brien, P.C.1    Dyck, P.J.2
  • 12
    • 0023213664 scopus 로고
    • Clinical reliability of manual muscle testing. Middle trapezius and gluteus medius muscles
    • Frese E, Brown M, Norton BI. Clinical reliability of manual muscle testing. Middle trapezius and gluteus medius muscles. Phys Ther. 1987;67(7):1072-76.
    • (1987) Phys Ther , vol.67 , Issue.7 , pp. 1072-1076
    • Frese, E.1    Brown, M.2    Norton, B.I.3
  • 15
    • 0031051056 scopus 로고    scopus 로고
    • Dvir Z. Grade 4 in manual muscle testing: The problem with submaximal strength assessment. Clin Rehabil. 1997;11(1):36-41.
    • Dvir Z. Grade 4 in manual muscle testing: The problem with submaximal strength assessment. Clin Rehabil. 1997;11(1):36-41.
  • 16
    • 72849182647 scopus 로고
    • Quantitative muscle testing: Principles and applications to research and clinical services
    • Beasley WC. Quantitative muscle testing: Principles and applications to research and clinical services. Arch Phys Med Rehabil. 1961;42:398-425.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 398-425
    • Beasley, W.C.1
  • 17
    • 0031785592 scopus 로고    scopus 로고
    • Comparison of three methods to assess muscular strength in individuals with spinal cord injury
    • Noreau L, Vachon J. Comparison of three methods to assess muscular strength in individuals with spinal cord injury. Spinal Cord. 1998;36(10):716-23.
    • (1998) Spinal Cord , vol.36 , Issue.10 , pp. 716-723
    • Noreau, L.1    Vachon, J.2
  • 18
    • 0037409993 scopus 로고    scopus 로고
    • Test-retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions
    • Larsson B, Karlsson S, Eriksson M, Gerdle B. Test-retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions. J Electromyogr Kinesiol. 2003;13(3):281-87.
    • (2003) J Electromyogr Kinesiol , vol.13 , Issue.3 , pp. 281-287
    • Larsson, B.1    Karlsson, S.2    Eriksson, M.3    Gerdle, B.4
  • 19
    • 0032824861 scopus 로고    scopus 로고
    • Handgrip strength testing: A review of the literature
    • Innes E. Handgrip strength testing: A review of the literature. Aust Occup Ther J. 1999;46(3):120-40.
    • (1999) Aust Occup Ther J , vol.46 , Issue.3 , pp. 120-140
    • Innes, E.1
  • 20
    • 0029963026 scopus 로고    scopus 로고
    • Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    • Andrews AW, Thomas MW, Bohannon RW. Normative values for isometric muscle force measurements obtained with hand-held dynamometers. Phys Ther. 1996;76(3):248-59.
    • (1996) Phys Ther , vol.76 , Issue.3 , pp. 248-259
    • Andrews, A.W.1    Thomas, M.W.2    Bohannon, R.W.3
  • 21
    • 21344437280 scopus 로고    scopus 로고
    • Break-technique handheld dynamometry: Relation between angular velocity and strength measurements
    • Burns SP, Spanier DE. Break-technique handheld dynamometry: Relation between angular velocity and strength measurements. Arch Phys Med Rehabil. 2005;86(7):1420-26.
    • (2005) Arch Phys Med Rehabil , vol.86 , Issue.7 , pp. 1420-1426
    • Burns, S.P.1    Spanier, D.E.2
  • 23
    • 0032018862 scopus 로고    scopus 로고
    • A standard method of shoulder strength measurement for the Constant score with a spring balance
    • Bankes MJ, Crossman JE, Emery RJ. A standard method of shoulder strength measurement for the Constant score with a spring balance. J Shoulder Elbow Surg. 1998;7(2):116-21.
    • (1998) J Shoulder Elbow Surg , vol.7 , Issue.2 , pp. 116-121
    • Bankes, M.J.1    Crossman, J.E.2    Emery, R.J.3
  • 24
    • 0029678279 scopus 로고    scopus 로고
    • Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength
    • Leggin BG, Neuman RM, Iannotti JP, Williams GR, Thompson EC. Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength. J Shoulder Elbow Surg. 1996;5(1):18-24.
    • (1996) J Shoulder Elbow Surg , vol.5 , Issue.1 , pp. 18-24
    • Leggin, B.G.1    Neuman, R.M.2    Iannotti, J.P.3    Williams, G.R.4    Thompson, E.C.5
  • 25
    • 0033064865 scopus 로고    scopus 로고
    • Muscle strength changes as measured by dynamometry following functional rehabilitation in individuals with spinal cord injury
    • Drolet M, Noreau L, Vachon J, Moffet H. Muscle strength changes as measured by dynamometry following functional rehabilitation in individuals with spinal cord injury. Arch Phys Med Rehabil. 1999;80(7):791-800.
    • (1999) Arch Phys Med Rehabil , vol.80 , Issue.7 , pp. 791-800
    • Drolet, M.1    Noreau, L.2    Vachon, J.3    Moffet, H.4
  • 26
    • 0026764481 scopus 로고
    • Motor recovery of the upper extremities in traumatic quadriplegia: A multicenter study
    • Ditunno JF Jr, Stover SL, Freed MM, Ahn JH. Motor recovery of the upper extremities in traumatic quadriplegia: A multicenter study. Arch Phys Med Rehabil. 1992;73(5):431-36.
    • (1992) Arch Phys Med Rehabil , vol.73 , Issue.5 , pp. 431-436
    • Ditunno Jr, J.F.1    Stover, S.L.2    Freed, M.M.3    Ahn, J.H.4
  • 28
    • 0025340147 scopus 로고
    • Subject variability of shoulder abduction strength testing
    • Magnusson SP, Gleim GW, Nicholas JA. Subject variability of shoulder abduction strength testing. Am J Sports Med. 1990;18(4):349-53.
    • (1990) Am J Sports Med , vol.18 , Issue.4 , pp. 349-353
    • Magnusson, S.P.1    Gleim, G.W.2    Nicholas, J.A.3
  • 31
    • 0344673379 scopus 로고    scopus 로고
    • A prospective evaluation of upper extremity tendon transfers in children with cervical spinal cord injury
    • Mulcahey MJ, Betz RR, Smith BT, Weiss AA. A prospective evaluation of upper extremity tendon transfers in children with cervical spinal cord injury. J Pediatr Orthop. 1999;19(3):319-28.
    • (1999) J Pediatr Orthop , vol.19 , Issue.3 , pp. 319-328
    • Mulcahey, M.J.1    Betz, R.R.2    Smith, B.T.3    Weiss, A.A.4
  • 32
    • 0033378664 scopus 로고    scopus 로고
    • Interfacing the body's own sensing receptors into neural prosthesis devices
    • Haugland M, Sinkjaer T. Interfacing the body's own sensing receptors into neural prosthesis devices. Technol Health Care. 1999;7(6):393-99.
    • (1999) Technol Health Care , vol.7 , Issue.6 , pp. 393-399
    • Haugland, M.1    Sinkjaer, T.2
  • 33
    • 13944249197 scopus 로고    scopus 로고
    • Measuring hand intrinsic muscle strength: Normal values and interrater reliability
    • Jacquemin GL, Burns SP, Little JW. Measuring hand intrinsic muscle strength: Normal values and interrater reliability. J Spinal Cord Med. 2004;27(5):460-67.
    • (2004) J Spinal Cord Med , vol.27 , Issue.5 , pp. 460-467
    • Jacquemin, G.L.1    Burns, S.P.2    Little, J.W.3
  • 34
    • 0021281230 scopus 로고
    • Reliability and validity of grip and pinch strength evaluations
    • Am
    • Mathiowetz V, Weber K, Volland G, Kashman N. Reliability and validity of grip and pinch strength evaluations. J Hand Surg [Am]. 1984;9(2):222-26.
    • (1984) J Hand Surg , vol.9 , Issue.2 , pp. 222-226
    • Mathiowetz, V.1    Weber, K.2    Volland, G.3    Kashman, N.4
  • 35
    • 0027675261 scopus 로고
    • Accuracy of the Jamar dynamometer
    • Harkonen R, Harju R, Alarana H. Accuracy of the Jamar dynamometer. J Hand Ther. 1993;6(4):259-62.
    • (1993) J Hand Ther , vol.6 , Issue.4 , pp. 259-262
    • Harkonen, R.1    Harju, R.2    Alarana, H.3
  • 36
    • 0036408174 scopus 로고    scopus 로고
    • Comparison of Rolyan and Jamar dynamometers for measuring grip strength
    • Mathiowetz V. Comparison of Rolyan and Jamar dynamometers for measuring grip strength. Occup Ther Int. 2002;9(3):201-9.
    • (2002) Occup Ther Int , vol.9 , Issue.3 , pp. 201-209
    • Mathiowetz, V.1
  • 37
    • 0022627348 scopus 로고
    • Analysis of the reliability and validity of the kinetic communicator exercise device
    • Farrell M, Richards JG. Analysis of the reliability and validity of the kinetic communicator exercise device. Med Sci Sports Exerc. 1986;18(1):44-49.
    • (1986) Med Sci Sports Exerc , vol.18 , Issue.1 , pp. 44-49
    • Farrell, M.1    Richards, J.G.2
  • 38
    • 0024455254 scopus 로고
    • Reliability of work measurements recorded during concentric and eccentric contractions of the knee extensors in healthy subjects
    • Wessel J, Gray G, Luongo F, Isherwood L. Reliability of work measurements recorded during concentric and eccentric contractions of the knee extensors in healthy subjects. Physiother Can. 1989;41:250-53.
    • (1989) Physiother Can , vol.41 , pp. 250-253
    • Wessel, J.1    Gray, G.2    Luongo, F.3    Isherwood, L.4
  • 39
    • 0025035870 scopus 로고
    • Isokinetic dynamometry
    • Delitto A. Isokinetic dynamometry. Muscle Nerve. 1990;13 Suppl:S53-57.
    • (1990) Muscle Nerve , vol.13 , Issue.SUPPL.
    • Delitto, A.1
  • 42
    • 0024504606 scopus 로고
    • Intrasession and intersession reliability of hand-held dynamometer measurements taken on brain-damaged patients
    • Riddle DL, Finucane SD, Rothstein JM, Walker ML. Intrasession and intersession reliability of hand-held dynamometer measurements taken on brain-damaged patients. Phys Ther. 1989;69(3):182-94.
    • (1989) Phys Ther , vol.69 , Issue.3 , pp. 182-194
    • Riddle, D.L.1    Finucane, S.D.2    Rothstein, J.M.3    Walker, M.L.4
  • 43
    • 0026465529 scopus 로고
    • Relationship between two measures of upper extremity strength: Manual muscle test compared to hand-held myometry
    • Schwartz S, Cohen ME, Herbison GJ, Shah A. Relationship between two measures of upper extremity strength: Manual muscle test compared to hand-held myometry. Arch Phys Med Rehabil. 1992;73(11):1063-68.
    • (1992) Arch Phys Med Rehabil , vol.73 , Issue.11 , pp. 1063-1068
    • Schwartz, S.1    Cohen, M.E.2    Herbison, G.J.3    Shah, A.4
  • 44
    • 0028084350 scopus 로고
    • Comparison of a hand-held and fixed dynamometer in measuring strength of patients with neuromuscular disease
    • Brinkmann JR. Comparison of a hand-held and fixed dynamometer in measuring strength of patients with neuromuscular disease. J Orthop Sports Phys Ther. 1994;19(2):100-104.
    • (1994) J Orthop Sports Phys Ther , vol.19 , Issue.2 , pp. 100-104
    • Brinkmann, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.