메뉴 건너뛰기




Volumn 28, Issue 3, 2007, Pages 382-384

Method for liquid viscosity coefficient measurement using inclined tube

Author keywords

Measuring method; Pure water; R134a; Viscosity

Indexed keywords

PRESSURE; RELIABILITY; VISCOSITY MEASUREMENT; WATER;

EID: 34249983133     PISSN: 0253231X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (7)
  • 2
    • 34250016530 scopus 로고    scopus 로고
    • Chinese source
  • 3
    • 34249992840 scopus 로고    scopus 로고
    • Chinese source
  • 4
    • 0037171255 scopus 로고    scopus 로고
    • A method of isolating surface tension and yield stress effects in a U-shaped scanning capillary-tube viscometer using a casson model
    • Kim S, Cho Y. A Method of Isolating Surface Tension and Yield Stress Effects in a U-Shaped Scanning Capillary-Tube Viscometer using a Casson Model. J. Non-Newtonian Fluid Mech., 2002, 103: 205-219
    • (2002) J. Non-Newtonian Fluid Mech. , vol.103 , pp. 205-219
    • Kim, S.1    Cho, Y.2
  • 5
    • 0036122893 scopus 로고    scopus 로고
    • Measurement of blood viscosity using mass-detecting sensor
    • Shin S, Keum D Y. Measurement of Blood Viscosity using Mass-Detecting Sensor. Biosensor and Bioelectronics, 2002, 17: 383-388
    • (2002) Biosensor and Bioelectronics , vol.17 , pp. 383-388
    • Shin, S.1    Keum, D.Y.2
  • 6
    • 1242332747 scopus 로고    scopus 로고
    • The marching velocity of the capillary meniscus in a microchannel
    • Yang L J, Yao T J, Tai Y C. The Marching Velocity of the Capillary Meniscus in a MicroChannel. J. Micromech. Microeng, 2004, 14: 220-225
    • (2004) J. Micromech. Microeng , vol.14 , pp. 220-225
    • Yang, L.J.1    Yao, T.J.2    Tai, Y.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.