메뉴 건너뛰기




Volumn 22, Issue 2, 2007, Pages 152-155

Optimization of a dried residue specimen preparation method for quantifying analytes in plutonium metal using WDXRF

Author keywords

Dried residue; Plutonium; Thin film; WDXRF

Indexed keywords

ANALYTES; DRIED RESIDUE; PLUTONIUM METAL; RADIOACTIVE LIQUIDS; SAMPLE ANALYSIS; SPECIMEN PREPARATION METHOD; WDXRF;

EID: 34249903859     PISSN: 08857156     EISSN: 19457413     Source Type: Journal    
DOI: 10.1154/1.2737463     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 1842533454 scopus 로고    scopus 로고
    • Development of the dried spot specimen preparation methodology and application to MXRF analysis
    • Colletti, L. P. and Havrilla, G. J. (1999). " Development of the dried spot specimen preparation methodology and application to MXRF analysis., " Adv. X-Ray Anal. 41, 291-300.
    • (1999) Adv. X-Ray Anal. , vol.41 , pp. 291-300
    • Colletti, L.P.1    Havrilla, G.J.2
  • 2
    • 84886758083 scopus 로고
    • Martell, C. J. and Hansel, J. M. (1988). Determining Gallium from Plutonium Using Anion Exchange and X-Ray Fluorescence, Report LA-11435 (Los Alamos National Laboratory, Los Alamos, NM).
    • (1988)
    • Martell, C.J.1    Hansel, J.M.2
  • 3
    • 0005071703 scopus 로고
    • Trace element analysis of solutions at the PPB level
    • Meltzer, C. and King, B.-S. (1991). " Trace element analysis of solutions at the PPB level., " Adv. X-Ray Anal. 34, 41-55.
    • (1991) Adv. X-Ray Anal. , vol.34 , pp. 41-55
    • Meltzer, C.1    King, B.-S.2
  • 4
    • 84981819103 scopus 로고
    • Solvent extraction-microdroplet X-ray fluorescence analyses of trace amounts of heavy metal ions
    • Murata, M., Omatsu, M., and Mushimoto, S. (1984). " Solvent extraction-microdroplet X-ray fluorescence analyses of trace amounts of heavy metal ions., " X-Ray Spectrom. 13, 83-86.
    • (1984) X-Ray Spectrom. , vol.13 , pp. 83-86
    • Murata, M.1    Omatsu, M.2    Mushimoto, S.3
  • 5
    • 2042505496 scopus 로고    scopus 로고
    • An order of magnitude improvement in detection limits achieved by using a new sample support in small spot XRF analysis
    • Nielson, A. J., Turner, D. C., Wilson, A., Wherry, D. C., and Wong, R. (1997). " An order of magnitude improvement in detection limits achieved by using a new sample support in small spot XRF analysis., " Adv. X-Ray Anal. 39, 799-804.
    • (1997) Adv. X-Ray Anal. , vol.39 , pp. 799-804
    • Nielson, A.J.1    Turner, D.C.2    Wilson, A.3    Wherry, D.C.4    Wong, R.5
  • 6
    • 1842533456 scopus 로고    scopus 로고
    • Quantification of gallium in dried residue samples by XRF: An improved sample preparation method for analyzing plutonium metal
    • Worley, C. G. (2002). " Quantification of gallium in dried residue samples by XRF: an improved sample preparation method for analyzing plutonium metal., " Adv. X-Ray Anal. 45, 421-426.
    • (2002) Adv. X-Ray Anal. , vol.45 , pp. 421-426
    • Worley, C.G.1
  • 7
    • 34249884889 scopus 로고    scopus 로고
    • Accurate quantification of radioactive materials by X-ray fluorescence: Gallium in plutonium metal
    • Worley, C. G. (2003). " Accurate quantification of radioactive materials by X-ray fluorescence: gallium in plutonium metal., " Adv. X-Ray Anal. 46, 369-374.
    • (2003) Adv. X-Ray Anal. , vol.46 , pp. 369-374
    • Worley, C.G.1
  • 8
    • 84886761778 scopus 로고    scopus 로고
    • Improvements in XRF specimen preparation using the dried residue method: Gallium in plutonium metal
    • Worley, C. G. and Colletti, L. P. (2004). " Improvements in XRF specimen preparation using the dried residue method: gallium in plutonium metal., " Adv. X-Ray Anal. 47, 98-103.
    • (2004) Adv. X-Ray Anal. , vol.47 , pp. 98-103
    • Worley, C.G.1    Colletti, L.P.2
  • 9
    • 1842533457 scopus 로고    scopus 로고
    • Accurate quantification of dried residue thin films using X-ray fluorescence
    • Worley, C. G. and Havrilla, G. J. (2001). " Accurate quantification of dried residue thin films using X-ray fluorescence., " Adv. X-Ray Anal. 44, 392-397.
    • (2001) Adv. X-Ray Anal. , vol.44 , pp. 392-397
    • Worley, C.G.1    Havrilla, G.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.