메뉴 건너뛰기




Volumn 145, Issue 1-2, 2007, Pages 336-338

Evaluation of Microwave-Assisted Process technology for HAPSITE's headspace analysis of volatile organic compounds (VOCs)

Author keywords

HAPSITE; Headspace analysis; Microwave energy; Microwave Assisted Process (MAP); Volatile organic compounds (VOCs) analysis

Indexed keywords

GAS CHROMATOGRAPHY; HEATING; MASS SPECTROMETERS;

EID: 34249897536     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2006.12.074     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 34249914311 scopus 로고    scopus 로고
    • J.R.J. Paré, U.S. Patents 5,377,426 (1995); 5,519,947 (1996); 5,675,909 (1997); 5,732,476 (1998); 5,884,417 (1999).
  • 2
    • 0028287010 scopus 로고
    • Microwave-Assisted Process (MAP™): a new tool for the analytical laboratory
    • Paré J.R.J., Bélanger J.M.R., and Stafford S.S. Microwave-Assisted Process (MAP™): a new tool for the analytical laboratory. Trends Anal. Chem. 13 4 (1994) 176
    • (1994) Trends Anal. Chem. , vol.13 , Issue.4 , pp. 176
    • Paré, J.R.J.1    Bélanger, J.M.R.2    Stafford, S.S.3
  • 3
    • 84986759412 scopus 로고
    • Microwave-Assisted Process (MAP™): application to the headspace analysis of VOCs in water
    • Paré J.R.J., Bélanger J.M.R., Li K., and Stafford S.S. Microwave-Assisted Process (MAP™): application to the headspace analysis of VOCs in water. J. Microcolum Sep. 7 (1995) 37-40
    • (1995) J. Microcolum Sep. , vol.7 , pp. 37-40
    • Paré, J.R.J.1    Bélanger, J.M.R.2    Li, K.3    Stafford, S.S.4
  • 4
    • 0030073786 scopus 로고    scopus 로고
    • Gas-phase extraction using the Microwave-Assisted Process (MAP™) for the analysis of dissolved volatile organic compounds (VOCs) in water
    • Paré J.R.J., Bélanger J.M.R., Thornton D.E., Li K., Llompart M., Fingas M., and Blenkinsopp S.A. Gas-phase extraction using the Microwave-Assisted Process (MAP™) for the analysis of dissolved volatile organic compounds (VOCs) in water. Spectrosc. Int. J. 13 (1996) 23-32
    • (1996) Spectrosc. Int. J. , vol.13 , pp. 23-32
    • Paré, J.R.J.1    Bélanger, J.M.R.2    Thornton, D.E.3    Li, K.4    Llompart, M.5    Fingas, M.6    Blenkinsopp, S.A.7
  • 5
    • 0007004729 scopus 로고    scopus 로고
    • Gas-phase extraction method using the Microwave-Assisted Process (MAP™) for the determination of aromatic contaminants in soil
    • Paré J.R.J., Li K., Bélanger J.M.R., and Llompart M. Gas-phase extraction method using the Microwave-Assisted Process (MAP™) for the determination of aromatic contaminants in soil. Spectrosc. Int. J. 13 (1996) 89-98
    • (1996) Spectrosc. Int. J. , vol.13 , pp. 89-98
    • Paré, J.R.J.1    Li, K.2    Bélanger, J.M.R.3    Llompart, M.4
  • 6
    • 34249866944 scopus 로고    scopus 로고
    • INFICON Technical Note diba84a1-c, HAPSITE Chemical Identification System, 2004.
  • 7
    • 34249904722 scopus 로고    scopus 로고
    • INFICON Technical Note no. diba84a1-a, HAPSITE Headspace Sampling System, 2003.
  • 8
    • 34249877476 scopus 로고    scopus 로고
    • US EPA Report No. EPA/600/R-98/142, Environmental Technology Verification Report, Field-Portable Gas Chromatograph/Mass Spectrometer, Inficon, Inc., HAPSITE, November 1998.
  • 9
    • 34249864193 scopus 로고    scopus 로고
    • US EPA Report No. EPA 542-R-01-011, Innovations in Site Characterization, Technology Evaluation: Real-Time VOC Analysis Using a Field Portable GC/MS, August 2001.
  • 10
    • 34249906222 scopus 로고    scopus 로고
    • Analysis of volatile organics by field-portable GC/MS
    • Crume C. Analysis of volatile organics by field-portable GC/MS. Environ. Test. Anal. May/June (2001) 25-26
    • (2001) Environ. Test. Anal. , Issue.May-June , pp. 25-26
    • Crume, C.1
  • 11
    • 0035561228 scopus 로고    scopus 로고
    • Environmental and forensics applications of field-portable GC/MS: an overview
    • Eckenrode B.A. Environmental and forensics applications of field-portable GC/MS: an overview. J. Am. Soc. Mass Spectrom. 12 (2001) 682-693
    • (2001) J. Am. Soc. Mass Spectrom. , vol.12 , pp. 682-693
    • Eckenrode, B.A.1
  • 12
    • 0028991567 scopus 로고
    • Comparison of data quality produced by an on-site field GC/MS and off-site permanent laboratory GC/MS: support of cleanup action at an inactive drum recycling facility
    • Schuetz S.P., Solinske P.J., Mickunas D.B., Humphrey A.M., and Turpin R.D. Comparison of data quality produced by an on-site field GC/MS and off-site permanent laboratory GC/MS: support of cleanup action at an inactive drum recycling facility. J. Hazard. Mater. 43 (1995) 67075
    • (1995) J. Hazard. Mater. , vol.43 , pp. 67075
    • Schuetz, S.P.1    Solinske, P.J.2    Mickunas, D.B.3    Humphrey, A.M.4    Turpin, R.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.