Volumn 32, Issue 1, 2007, Pages 143-148

Artificial chordae for pediatric mitral and tricuspid valve repair

Author keywords

Artificial tendinous chords; Congenital; Mitral valve repair

Indexed keywords

ACUTE DISEASE; ANNULOPLASTY; ARTICLE; CARDIOLOGIST; CHILD; CHORDA TENDINEA; CLINICAL ARTICLE; CONTROLLED STUDY; DISEASE ASSOCIATION; DISEASE SEVERITY; ECHOCARDIOGRAPHY; ENDOCARDITIS; FEMALE; FOLLOW UP; HEART ATRIOVENTRICULAR VALVE; HUMAN; MALE; MITRAL VALVE REGURGITATION; MITRAL VALVE REPLACEMENT; MORTALITY; PRIORITY JOURNAL; RHEUMATIC HEART DISEASE; TRICUSPID VALVE REGURGITATION; WOUND DEHISCENCE;

EID: 34249886810     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2007.03.035     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 0024802835 scopus 로고
    • Replacement of chordae tendinae with expanded polytetrafluoroethylene sutures
    • David T.E. Replacement of chordae tendinae with expanded polytetrafluoroethylene sutures. J Card Surg 4 4 (1989) 286-290
    • (1989) J Card Surg , vol.4 , Issue.4 , pp. 286-290
    • David, T.E.1
  • 2
    • 0025187715 scopus 로고
    • Chordal replacement in mitral valve repair
    • Frater R.W., Vetter H.O., Zussa C., and Dahm M. Chordal replacement in mitral valve repair. Circulation 82 5 Suppl. (1990) IV125-IV130
    • (1990) Circulation , vol.82 , Issue.5 SUPPL
    • Frater, R.W.1    Vetter, H.O.2    Zussa, C.3    Dahm, M.4
  • 3
    • 0028285952 scopus 로고
    • Seven-year experience with chordal replacement with expanded polytetrafluoroethylene in floppy mitral valve
    • Zussa C., Polesel E., Da Col U., Galloni M., and Valfre C. Seven-year experience with chordal replacement with expanded polytetrafluoroethylene in floppy mitral valve. J Thorac Cardiovasc Surg 108 (1994) 37-41
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 37-41
    • Zussa, C.1    Polesel, E.2    Da Col, U.3    Galloni, M.4    Valfre, C.5
  • 4
    • 0031744908 scopus 로고    scopus 로고
    • Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures
    • David T.E., Omran A., Armstrong S., Sun Z., and Ivanov J. Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures. J Thorac Cardiovasc Surg 115 (1998) 1279-1286
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 1279-1286
    • David, T.E.1    Omran, A.2    Armstrong, S.3    Sun, Z.4    Ivanov, J.5
  • 6
    • 0032961043 scopus 로고    scopus 로고
    • Use of expanded polytetrafluoroethylene sutures as artificial tendinous cords in children with congenital mitral regurgitation
    • Kawahira Y., Yagihara T., Uemura H., Ishizaka T., Yoshizumi K., and Kitamura S. Use of expanded polytetrafluoroethylene sutures as artificial tendinous cords in children with congenital mitral regurgitation. Eur J Cardiothorac Surg 15 (1999) 289-293
    • (1999) Eur J Cardiothorac Surg , vol.15 , pp. 289-293
    • Kawahira, Y.1    Yagihara, T.2    Uemura, H.3    Ishizaka, T.4    Yoshizumi, K.5    Kitamura, S.6
  • 10
    • 1342280419 scopus 로고    scopus 로고
    • Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation
    • Kobza R., Kurz D.J., Oechslin E.N., Pretre R., Zuber M., Vogt P., and Jenni R. Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation. Heart 90 (2004) 319-323
    • (2004) Heart , vol.90 , pp. 319-323
    • Kobza, R.1    Kurz, D.J.2    Oechslin, E.N.3    Pretre, R.4    Zuber, M.5    Vogt, P.6    Jenni, R.7
  • 12
  • 13
    • 20544447332 scopus 로고    scopus 로고
    • Successful repair of critical tricuspid regurgitation secondary to ruptured papillary muscle in a newborn
    • Lim K.A., Huh J., and Jun T.G. Successful repair of critical tricuspid regurgitation secondary to ruptured papillary muscle in a newborn. Cardiol Young 14 (2004) 450-452
    • (2004) Cardiol Young , vol.14 , pp. 450-452
    • Lim, K.A.1    Huh, J.2    Jun, T.G.3
  • 14
    • 0029038134 scopus 로고
    • Critical tricuspid regurgitation secondary to ruptured chordae tendineae mimicking a mass on the tricuspid valve in a newborn
    • Atalay S., Imamoglu A., Uluoglu O., and Ikizler C. Critical tricuspid regurgitation secondary to ruptured chordae tendineae mimicking a mass on the tricuspid valve in a newborn. Pediatr Cardiol 16 (1995) 133-136
    • (1995) Pediatr Cardiol , vol.16 , pp. 133-136
    • Atalay, S.1    Imamoglu, A.2    Uluoglu, O.3    Ikizler, C.4
  • 15
    • 0033970240 scopus 로고    scopus 로고
    • Surgical repair of the prolapsing anterior leaflet in degenerative mitral valve disease
    • El Khoury G., Noirhomme P., Verhelst R., Rubay J., and Dion R. Surgical repair of the prolapsing anterior leaflet in degenerative mitral valve disease. J Heart Valve Dis 9 1 (2000) 75-80
    • (2000) J Heart Valve Dis , vol.9 , Issue.1 , pp. 75-80
    • El Khoury, G.1    Noirhomme, P.2    Verhelst, R.3    Rubay, J.4    Dion, R.5
  • 17
    • 0030734240 scopus 로고    scopus 로고
    • Long-term results of artificial chordae implantation in patients with mitral valve prolapse
    • Eishi K., Kawazoe K., Nakano K., Kosakai Y., Sasako Y., and Kobayashi J. Long-term results of artificial chordae implantation in patients with mitral valve prolapse. J Heart Valve Dis 6 (1997) 594-598
    • (1997) J Heart Valve Dis , vol.6 , pp. 594-598
    • Eishi, K.1    Kawazoe, K.2    Nakano, K.3    Kosakai, Y.4    Sasako, Y.5    Kobayashi, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.